BKAGX-V-1/200 Overview

Fuse,

BKAGX-V-1/200 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
Base Number Matches1
Bussmann
®
Fast-Acting Glass Fuses
For ⁄Ω¢∑ ≈ 1∑ (6.3mm ≈ 25.4mm)
Dimensional Data
.266
"
1.500
"
(REF)
AGX
AGX-V
General Information:
• Glass. Formerly designated
8AG.
• Types MJB and MJW now called AGX.
• For instruments, electronic, and small appliance circuits.
• Mounts in Buss panel mounted fuseholders types HJM, HMS,
and HJL; In-line holders types HHB, HFB, and HRK; and Buss
fuseblocks 4520 and 3808 series and
⁄Ω¢∑
clips.
Time-Current Characteristic Curves–Average Melt
(Full Size Curves Available)
⁄Ω¢
1
2
100
5
AMPERE
RATING
1"
(±0.031)
1.042"
(±0.031)
.25"
(±0.003)
1.500
"
(REF)
TIME IN SECONDS
U.L.
Recog.
Catalog Symbol:
AGX
⁄Ω¢∑ ≈ 1∑ (6.3mm ≈ 25.4mm) 8AG
Fast-Acting
Agency Approvals:
Std. 248-14
0-5A U.L. Listed, Guide JDYX, File E19180
5.1-20A U.L. Recognized, Guide JDYX2, File E19180
CSA Certified, C22.2 No. 248.14, Class 1422-01, File 53787
Body Material:
Glass
Ferrule Material:
Brass
Ferrule Plating:
Nickel
Packaging & Ordering Information:
AGX
Package Code
Blank
5 in
BK/
100 in
Product
Symbol
0–15 AMP: 0.32
"
(REF)
20–30 AMP: 0.40
"
10
1
V
(See Table)
Rated Current
Lead
Blank -no lead
V-Axial lead
Electrical Ratings (Catalog Symbol and Amperes)
250 Volts AC
AGX-⁄Ω∞ºº
AGX-⁄Ω™ºº
AGX-⁄Ω¡ºº
AGX-⁄Ω£™
AGX-⁄Ω¡§
AGX-⁄Ω¡º
AGX-⁄Ω•
AGX-¤Ω¡º
AGX-‹Ω¡§
U.L.
Listed
& CSA
.1
250 Volts AC
AGX-⁄Ω¢
AGX-‹Ω¡º
AGX-‹Ω•
AGX-›Ω¡º
AGX-⁄Ω™
AGX-‹Ω¢
AGX-1
AGX-1⁄Ω¢
AGX-1⁄Ω™
U.L.
Listed
& CSA
250 Volts AC
AGX-2
AGX-2⁄Ω™
AGX-3
AGX-4
AGX-5
AGX-6
AGX-7
U.L.
Listed
U.L. Listed
& CSA
32 Volts AC
AGX-8
AGX-10
AGX-15
AGX-20
AGX-25
AGX-30
125 Volts AC
.1
10
1
RMS SYMMETRICAL CURRENT IN AMPERES
Test Specifications
Fuse
Load Opening Time
110% 4 Hours (min.)
135% 1 Hour (max.)
200% 5 Seconds (max.)
Carton Quantity and Weight
Ampere
Ratings
⁄Ω∞ºº-30
*Weight per carton.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
Carton
Qty.
100
Weight*
Lbs.
0.76
Kg.
345
AGX
(⁄Ω
짧 to 30A)
AGX
(⁄Ω
짧
to 2A)
The only controlled copy of this BIF document is the electronic read-only version located on the
Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This
bulletin is intended to clearly present comprehensive product data and provide technical infor-
mation that will help the end user with design applications. Bussmann reserves the right, without
notice, to change design or construction of any products and to discontinue or limit distribution
of any products. Bussmann also reserves the right to change or update, without notice, any
technical information contained in this bulletin. Once a product has been selected, it should be
tested by the user in all possible applications.
12-23-98
SB98107
Rev. A
Form No. AGX
Page 1 of 1
BIF Doc #2041
100
.01
About the data sending API AF_DataRequest() response problem
[color=#000]After analyzing the captured packets, I found that each sent packet carries an ACK request, which means that the receiving end needs to send an acknowledgment signal, but I don't know wher...
马小跳life RF/Wirelessly
I am going to use OV2640 camera and display it on LCD. I will send some information first.
OV2640 Camera Module [size=14px]Software Application Notes[/size][size=14px][/size] [size=14px] [/size] [size=14px] [/size] [size=14px] [/size] OV2640 Camera Module [size=14px]Hardware Application Not...
dontium RF/Wirelessly
What if the uploaded image is not used? See here
Hello everyone~ I am here. Recently, I have encountered some netizens asking the administrator about the problem of uploading pictures. Here I will answer them for you.The forum defaults to the pictur...
okhxyyo Talking
Why can't this voltage regulator circuit stabilize the voltage?
XMM2 is 6.155mV, XMM1 is 7.395mV. Please advise!...
clark Analog electronics
TMS320C6747 library function to implement IFFT
As the title says, please help me with some advice...
yelyly DSP and ARM Processors
Design scheme for mobile phone PCB reliability 1
The increase in mobile phone functions has put increasing demands on PCB design. With the advent of a new round of Bluetooth devices, cellular phones and the 3G era, engineers are paying more and more...
探路者 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1404  2551  990  41  879  29  52  20  1  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号