EEWORLDEEWORLDEEWORLD

Part Number

Search

5432.61121

Description
Mains Power Connector, 6A, 125/250VAC, Female and Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size481KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

5432.61121 Overview

Mains Power Connector, 6A, 125/250VAC, Female and Male, Solder Terminal, ROHS COMPLIANT

5432.61121 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60320-1/C14; IEC/EN 60320-2-2; VDE, CSA; UL 94V-0
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderFEMALE AND MALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings6A, 125/250VAC
Manufacturer's serial numberFKH
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts6
Base Number Matches1
Power entry modules with line filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
Inlet filter, modular assembling
 
5411.XX5X.XXX 
Appliance inlet 
Fuseholder 
Line filter
5431.X05X.XXX 
Appliance inlet 
Appliance outlet 
Switch 
Line filter
C14
70° C
 
 
- Panel Mount:
Snap-In Version from front side
- 2 - 5 Functions:
Inlet Protection class I, Outlet, Line switch 2-pole, Fuseholder for fuse-
links 5 x 20 mm 1- or 2-pole, Line filter in standard and medical ver-
sion
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
- Alternative: version without line filter Felcom 64
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
References
Weblinks
General Product Information
Approvals
- Line switch with other rocker marking
- VDE License Number: 101307
- UL License Number: E72928
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 6 A @ Ta 40 °C / 250 VAC; Hz 50
1 - 6 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
condition) pin-temperature 70 °C, 10 A,
Protection class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
EMC products

Design of ESD protection structure for CMOS circuits
ESD (electrostatic discharge) is one of the most serious failure mechanisms in CMOS circuits. In severe cases, it can cause the circuit to burn itself out. This paper discusses the necessity of ESD pr...
fish001 Analogue and Mixed Signal
AD sampling input problem?
I want to design a circuit that can collect ±10V voltage input. The design idea is to convert the ±10V voltage into 0-20V DC, and then attenuate the 0-20V DC to 0-5V and input it to AD for conversion....
bigbat Analog electronics
MSP430 5529 12-bit AD conversion
void ADC_Init(void) { ADC12CTL0 |= ADC12SHT02 + ADC12ON; //ADC10ON=1-->ADC10 turns on ADC12CTL0 |= ADC12REFON + ADC12REF2_5V ; //Select internal reference source 2.5V, turn on reference source ADC12CT...
xcw Microcontroller MCU
TMS320C55x - Instruction encoding and coff object file loading related issues
Hello engineers, I am studying the simulation program of TI's TMS320C55x recently. I have some questions about the distribution of the code segment (i.e. instruction code) after the compiled .out file...
wyj107 Embedded System
Recruiting brushless motor controller hardware development engineer
Headhunting position in [Shanghai] or [Changzhou] [/size] [size=14px]Job responsibilities: [/size][u][size=14px]Main work: Hardware development of brushless [/size][size=14px] motor controller [/size]...
July2018 Recruitment
Compatible with Series 2600 SourceMeter instrument program commands
One aspect of the cost of implementing new test equipment involves switching from an existing, stable software program to support a new product.2600AWhen you purchase a Series 2600 SourceMeter instrum...
Jack_ma Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2823  1214  139  1833  1657  57  25  3  37  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号