EEWORLDEEWORLDEEWORLD

Part Number

Search

3CR16L

Description
Thermal Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size1MB,1 Pages
ManufacturerAltech
Websitehttp://www.altechcorp.com/
Download Datasheet Parametric Compare View All

3CR16L Overview

Thermal Magnetic Circuit Breaker,

3CR16L Parametric

Parameter NameAttribute value
MakerAltech
Reach Compliance Codeunknown
Circuit protection typeTHERMAL MAGNETIC
Base Number Matches1
L-Series - UL489 Miniature Molded Case Circuit Breaker -
3 pole C-Trip
Rated
Current
0.2A
0.5A
1.0A
1.6A
2.0A
3.0A
4.0A
5.0A
6.0A
8.0A
10A
12A
13A
15A
16A
20A
25A
30A
32A
40A
50A
60A
63A
Type/
Cat. No.
3CU02L
3CU05L
3CU1L
3CU1.6L
3CU2L
3CU3L
3CU4L
3CU5L
3CU6L
3CU8L
3CU10L
3CU12L
3CU13L
3CU15L
3CU16L
3CU20L
3CU25L
3CU30L
3CU32L
3CU40L
3CU50L
3CU60L
3CU63L
C and D Trip, Less than 10A
120
60
40
20
Minutes
LISTED
E305318
10
8
6
4
2
1
40
20
10
5
Tripping time t
1
0.5
Seconds
0.05
0.1
Three Pole
Standard Pack:
4
Weight:
1.7kg (3.74 lb.)
0.01
C
1
2
3
4
Multiple of Rated Current
D
5 6 7 8 9 10 12 14 16 20
1.05 1.3
C and D Trip, 10A and higher
7200
3600
2400
1200
Minutes
Tripping time t
AC Version Current/ Voltage Rating
0.2-63A/240VAC, 0.2-32A/480Y/277VAC*
Calibration Temperature
Operating Temperature
Storage Temperature
Terminal Size Acceptability:
Solid Wire
Stranded Wire
Terminal Torque
Terminal Protection Degree
Electrical Life
Mechanical Life
Wire Connection
*One
device dual voltage ratings.
14.5mm (0.57 in.)
40°C (104°F)
-25° to 60°C (-13° to 140°F)
-25° to 75°C (-13° to 167°F)
18 AWG -10 AWG
18 AWG -6 AWG
2.8 Nm (25 lb-in.)
IP20
6000 cycles on/off
100000 cycles on/off
copper wire only 60/75°C
Seconds
600
480
360
240
120
60
40
20
10
5
1
0.5
0.05
0.1
0.01
C
1
2
3
4
Multiple of Rated Current
D
5 6 7 8 9 10 12 14 16 20
1.05 1.3
109mm (4.29 in.)
45mm (1.77 in.)
69mm (2.72 in.)
AC
- short CirCuit interruptinG rAtinG
No.
Poles
1
2-4
Type
AC
AC
0.2-32A
10kA@120, 240, 277V
33-63A
10kA@120, 240V
10kA@120, 240V, 480Y/277V 10kA@120, 240V
6.5mm
(0.26 in.)
17.5mm (0.69 in.)
44mm (1.73 in.)
60mm (2.36 in.)
35mm (1.38 in.)
52.5mm (2.07 in.)
For ring tongue terminal version, replace “U” with “R” in part number. For example
1CR20L
instead of
1CU20L.

3CR16L Related Products

3CR16L 3CR15L
Description Thermal Magnetic Circuit Breaker, Thermal Magnetic Circuit Breaker,
Maker Altech Altech
Reach Compliance Code unknown unknown
Circuit protection type THERMAL MAGNETIC THERMAL MAGNETIC
Base Number Matches 1 1

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 681  2784  1441  91  2  14  57  30  2  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号