EEWORLDEEWORLDEEWORLD

Part Number

Search

KC-J1A-300L

Description
Electromechanical Relay, 3PDT, 29VDC (Coil), 25A (Contact), 28VDC (Contact), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size754KB,13 Pages
ManufacturerEsterline Technologies Corporation
Download Datasheet Parametric View All

KC-J1A-300L Overview

Electromechanical Relay, 3PDT, 29VDC (Coil), 25A (Contact), 28VDC (Contact), Random, AC/DC Output

KC-J1A-300L Parametric

Parameter NameAttribute value
MakerEsterline Technologies Corporation
Reach Compliance Codecompliant
body width25.78 mm
body height25.65 mm
Body length or diameter25.78 mm
Coil operating voltage (DC)18 V
Coil resistance290 Ω
Maximum coil voltage (DC)29 V
Nominal coil voltage28 V
Coil/Input Power TypeDC
Contact (AC) maximum rated load I15A@115VAC
Contact (AC) maximum rated load M10A@115VAC
Contact (AC) maximum rated R load25A@115VAC
Maximum contact current (AC)25 A
Maximum contact current (DC)25 A
Contact (DC) maximum rated R load25A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Dielectric strength between breaking contacts1250 Vrms
Electrical life50000 Cycle(s)
Input switching control typeRandom
Insulation resistance100000000 Ω
Number of terminals11
operating hours15 ms
Maximum operating temperature125 °C
Minimum operating temperature-70 °C
PCB hole count11
physical size25.78mm x 25.78mm x 25.65mm
Relay style3 FORM C
Relay function3PDT
release time15 ms
sealHERMETICAL
Terminal length0.0068 inch
Termination typeSOLDER
weight85 g
Base Number Matches1
SERIES KC
ENGINEERING DATA SHEET
RELAY - NONLATCH
3 PDT, 25 AMP
All welded construction
Contact arrangement
Qualified to
3 PDT configuration in one inch
cube
MIL-PRF-6106
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions
28 Vdc; 115 Vac, 400 Hz, 1Ø
and 115/200 Vac, 400 Hz 3Ø
0.188lb max
1.01in x 1.01in x 1.00in
Hermetically sealed, corrosion resistant metal can.
Detail specifications and ordering data appear on the following
pages.
APPLICATION NOTES:
101
102
103E
007
APPLICABLE SOCKET:
SO-1057-8912
CONTACT ELECTRICAL CHARACTERISTICS
Contact rating
per pole and load
type [1]
Resistive [2]
Inductive [3]
Motor
Lamp
Overload
Rupture
Circuit Breaker
Compatible [10]
Load current in Amps
@28 Vdc
25
12
10
5
40
60
-
@115 Vac 400
Hz
25
15
10
5
80
100
-
@115/200 Vac, 400 Hz, 3Ø
25
15
10
5
80
100
-
@115/200 Vac, 60 Hz, 3Ø [9]
2.5
2.5
2
1
N/A
N/A
Featuring
LEACH
©
power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 07/10
- 150 -
Page 1 of 4
IGBT drive waveform
I would like to ask what the IGBT drive waveform I measured is like this? As shown in the figure below, please explain it to me....
韬沉哈哈 Integrated technical exchanges
Analysis of Frequency Shifting Performance of Digital Phase Shifter
The principle of frequency shifting by digital phase shifter is discussed, and the main performance indicators of frequency shifting by digital phase shifter, namely spurious suppression ratio and car...
JasonYoo Analog electronics
Please help me with a program!
I am a student. This question is from the book, and the program is the answer given by the teacher, but I think there is a problem and I would like to ask the experts to take a look and see if there i...
recall100001 MCU
Why is there only the Files tab after clicking New Project or File after installing Platform Builder?
After installing PB, click New-Click New Project or Files, but the box that appears only has the Files tab, which is the same as the Files tab in EVC, but the Project tab is missing. Why?...
LXD13204234670 Embedded System
Emergency help! WinCE compilation error
Checking for uncleared variables The system cannot execute the specified program. The pipe to which the procedure attempted to write does not exist. The pipe to which the procedure attempted to write ...
gjinzi Embedded System
MSP430F5529 Unified Clock System UCS
Module clock source: MODOSC, generates MODCLK clock source signal, generally only provides services for flash memory control module and ADC12 module. This module is automatically shut down when not in...
fish001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 441  2786  105  1359  494  9  57  3  28  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号