EEWORLDEEWORLDEEWORLD

Part Number

Search

55.14.9.012.00741

Description
Electromechanical Relay, 4PDT-CO, MBB, 13.2VDC (Coil), 1W@12VDCmW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.14.9.012.00741 Overview

Electromechanical Relay, 4PDT-CO, MBB, 13.2VDC (Coil), 1W@12VDCmW (Coil), Random, AC/DC Output

55.14.9.012.00741 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (DC)9.6 V
Coil power1000 mW
Coil resistance140 Ω
Maximum coil voltage (DC)13.2 V
Nominal coil voltage12 V
Coil/Input Power TypeDC
Contact (AC) maximum rated power R load1750VA@250VAC
Contact (AC) maximum rated R load15A@250VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)250 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life150000 Cycle(s)
End contact materialSILVER NICKEL
Input switching control typeRandom
Number of terminals14
operating hours11 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count14
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style4 FORM C
Relay function4PDT-CO
release time3 ms
Terminal length0.0048 inch
Termination typeSOLDER
Base Number Matches1
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
What wireless technology would you most like to know more about?
The New Year is over. Have you gained another 10-25 pounds? :pleased: Although it is not the end of the first month of the lunar year, we still need to stretch our muscles. Friends who want to learn w...
soso RF/Wirelessly
[Texas Instruments Video] WEBENCH PMU power system architecture
Wanda will demonstrate how to use TI's WEBENCH PMU power system architecture to optimize the power management unit (PMU) in your power supply design. Using the power management unit function in the WE...
德州仪器_视频 Analogue and Mixed Signal
Measuring the instantaneous flow rate of flow meters
Could you please tell me how to measure the instantaneous flow and cumulative flow of the flow meter for control? Thank you...
xiaoxiao1 Test/Measurement
Free circuit
After the national competition, I finally got the first place. If you need information about signals, please contact me, including information, previous year's question reports, various circuits, and ...
单片机菜菜 Electronics Design Contest
LTC6915 is reverse grounded and forward connected to a bipolar signal. What is the final output?
[i=s]This post was last edited by Wpzz on 2021-12-9 15:46[/i]Big brother, please help me, I haven't learned analog electronics well, it's a bit vague...
Wpzz Analog electronics
Find MSP-EXP430G2 LaunchPad
Does anyone have extra MSP-EXP430G2 LaunchPad boards? I want to buy a cheap MSP-EXP430G2 LaunchPad board....
飞鹰55555 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 316  510  754  2032  1941  7  11  16  41  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号