Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size52KB,2 Pages
ManufacturerMolex
Websitehttps://www.molex.com/molex/home
Download Datasheet Parametric View All

74105-47 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

74105-47 Parametric

Parameter NameAttribute value
MakerMolex
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresLOW PROFILE, POLYETHYLENE, 94V-0
Fastening methodSCREW
Manufacturer's serial number74
Installation typeBOARD
Number of layers1
Rows1
Number of channels5
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
Base Number Matches1
SERIES 74
SERIES 74
BEAU Terminal Blocks
BEAU
.438" PCB Low Profile Barrier Terminal Strip
Description
The series 74 PCB barrier terminal strip is
the low profile version of our popular
series 73 terminal block. The product
series is available with the broad selection
of screw, terminal and hardware options.
The .58" product height is very low
when considering the maximum 30 Amp,
10 AWG wire rating.
Made in the USA, all Beau terminal
blocks embody the highest quality
standards in the industry-using the finest
materials and world class manufacturing
processes. They meet or exceed all
applicable industry standards.
Features
Low profile
and rated for 30 Amps.
The .58" high series 74 is our lowest
profile product to accept a 10 AWG
wire.
Robust and durable,
74 series screw
terminals are ultrasonically
welded into the thermoplastic
insulator, eliminating terminal
twisting and associated solder joint
failure.
Wide variety of options.
Our broad
range of screw, terminal, hardware
and mounting options allows us to
save you assembly costs and improve
interconnect performance.
PRODUCT RATINGS
#6-32 BINDING HEAD SCREW
UL
Class B
15 Amps @ 300 V 14 AWG
Class C
15 Amps @ 300 V 14 AWG
CSA
Class B
Class D
20 Amps @ 150 V 14 AWG
10 Amps @ 300 V 14 AWG
TECHNICAL SPECIFICATIONS
ELECTRICAL
DWV
IR
MECHANICAL
Tightening torque
Maximum torque
Wire strip length
Wire range
ENVIRONMENTAL
OPTIONS
-45
-45-56
-47
-49
-50
-58
-59
-A
-C
-F
-M
-P
Slotted screw
Stainless steel screw, slotted
Screws up, wire ready
Brass, phillips/slotted screw
Clamp washer, phillips/slotted screw
No screws, barrier only
Screws supplied unassembled
Oversize screws, #8-32, slotted
No mounting ends
Rap-attach mounts
3.5 M screw, slotted
.040" standoff pads
130°C insulator
8500 VDC
>5000 Megohms
8 in-lbs.
13 in-lbs.
5/16"
10 to 24 AWG
#6-32 WIRE CLAMP SCREW
UL
Class B
20 Amps @ 300 V 12 AWG
Class C
20 Amps @ 300 V 12 AWG
CSA
Class B
Class D
20 Amps @ 150 V 12 AWG
10 Amps @ 300 V 12 AWG
#8-32 WIRE CLAMP SCREW
UL
Class B
30 Amps @ 300 V 10 AWG
CSA
Class C
Class B
Class D
30 Amps @ 300 V 10 AWG
30 Amps @ 150 V 10 AWG
10 Amps @ 300 V 10 AWG
Continuous Use Temp
RTI electrical
RTI mechanical w/o impact
110
o
C
110
o
C
-V
MATERIALS
NOTE: 3.5M and 4.0M screws carry #6-32
and #8-32 screw ratings respectively.
Insulator
Terminal
Screws
Thermoplastic,
UL94V-0, black
Brass, tin-lead plate
#6-32, phillips/slotted, steel,
zinc chromate plate
HOW TO ORDER
7 4
SERIES
X
TERMINAL
STYLE
123
567
89
X X - X X
NO. OF
POLES
2 to 30
(Dash #s above
and
opposite page)
OPTIONS
AGENCY LISTINGS
UL
CSA
File No. E48521
Guide No. XCFR2
File No. 025562
*Consult factory for combinations of screw options.
Molex Industrial Division
New England Operations
Gilford, NH 03246-6600
Phone
(603) 524-5101
Fax
(603) 524-1627
Internet www.beauint.com
I accidentally got to know another administrator
[align=center]EEWORLD Xiang Nong [/align][align=left][size=4]Xiang Nong, deputy editor-in-chief of EEWORLD. He was called "one of the two journalists that China can talk to" by Intel Chairman Barrett;...
open82977352 Talking
Urgent help: CPLD has two pwm output pins and cannot detect signals.
module pwm_f2 (clk,rst,pwm1,pwm2,clk_div); input rst; input clk; output reg pwm1; output reg pwm2; output reg clk_div; reg[19:0]cnt; always@(posedge clk or negedge rst) if (!rst) cnt 0) && (dead_cnt<2...
824653578 FPGA/CPLD
APA600 core current abnormality
I chose the APA600 chip, but when the device is heated, the core power consumption goes up. I measured that the current is about 14mA higher, and it is normal when the temperature drops. If anyone has...
ZQ0313023 FPGA/CPLD
[Silicon Labs BG22-EK4108A Bluetooth Development Review] 1: IoT product introduction and BLE environment construction
1 Introduction I have been engaged in the industry of IoT smart home, and I am quite familiar with Silicon. Their Zigbee is the No.1 in the industry, and I use it a lot in IoT Zigbee. I am very famili...
忆作音符 Development Kits Review Area
System hang problem
I have two questions for you: 1. Why does the screen backlight not turn off after I click 'Start' - 'Suspend'? How can I make the screen turn off after clicking 'Suspend'? 2. I set a button externally...
zqf5 Embedded System
Which pins of the microcontroller are connected to the ISP and JTAG interfaces? Is there any universal standard?
I'm new to this, please help me out, experts!...
f_xiaoqiang Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2277  1946  1263  2881  2032  46  40  26  59  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号