EEWORLDEEWORLDEEWORLD

Part Number

Search

328303E028

Description
Electromechanical Relay, 3PDT, 29VDC (Coil), 25A (Contact), 28VDC (Contact), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size355KB,4 Pages
ManufacturerSTPI Siege Social
Download Datasheet Parametric View All

328303E028 Overview

Electromechanical Relay, 3PDT, 29VDC (Coil), 25A (Contact), 28VDC (Contact), Random, AC/DC Output

328303E028 Parametric

Parameter NameAttribute value
MakerSTPI Siege Social
Reach Compliance Codeunknown
body width26 mm
body height25.7 mm
Body length or diameter26 mm
Coil operating voltage (DC)19.8 V
Coil release voltage (DC)1.5 V
Coil resistance290 Ω
Maximum coil voltage (DC)29 V
Nominal coil voltage28 V
Coil/Input Power TypeDC
Contact (AC) maximum rated load I15A@115VAC
Contact (AC) maximum rated R load25A@115VAC
Maximum contact current (AC)25 A
Maximum contact current (DC)25 A
Contact (DC) maximum rated R load25A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Dielectric strength between breaking contacts1250 Vrms
Electrical life50000 Cycle(s)
Input switching control typeRandom
Insulation resistance100000000 Ω
Number of terminals11
operating hours10 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB hole count11
physical size26mm x 26mm x 25.7mm
Relay style3 FORM C
Relay function3PDT
release time10 ms
sealHERMETICAL
Terminal length0.0071 inch
Termination typeSOLDER
weight97 g
Base Number Matches1
328 3
RT -
3
PDT
/25
A
RELAIS HERMETIQUES
MONOSTABLES
HERMETICALLY SEALED
NON LATCHING
RELAY
CARACTERISTIQUES GENERALES
GENERAL CHARACTERICS
Combinaison des contacts
Contact arrangement
3 RT
3PDT
Pouvoir de coupure 28 Vcc - 1 5 V/400 Hz
1
Contact rating 28 Vdc - 115 V/400 Hz
Circuit résistif
Resistive load
25 A
25 Amps
Circuit inductif (L/R = 5 ms)
Inductive load (L/R = 5 ms)
1 A (28 Vc) / 1 A (1 5 V - 400 Hz)
2
5
1
12 Amps (28 Vdc) / 15 Amps (115 V - 400 Hz)
Circuit moteur
Motor load
10 A
10 Amps
Circuit lampe
Lamp load
5A
5 Amps
Alimentation
Supply
Courant continu (polarisé) ou alternatif 400Hz
Direct current (polarised) or alternative current 400 Hz
Masse
Weight
85 g à 97 g max.
85 g to 97 g max.
Normes applicables en annexe
See appendice for applicable specifications
ENVIRONNEMENT
ENVIRONMENT
Température de fonctionnement
Temperature range
- 65° à + 1
25°C
- 65° to + 125°C
Position de fonctionnement
Operating position
Indifférente
Any
Tenue aux vibrations
Resistance against vibrations
Sinus : 30 g - 10 - 3 000 Hz / Aléatoire : 0,4 g
2
/Hz - 50 - 2 000 Hz
Sinus : 30 g - 10 - 3 000 Hz / Random : 0,4 g
2
/Hz - 50 - 2 000 Hz
Tenue aux chocs
Shocks resistance
200 g - 6 ms / 100 g - 1 ms
1
200 g - 6 ms / 100 g - 11 ms
Tenue aux secousses
Shake resistance
40 g
40 g
Accélération
Acceleration
20 g
20 g
Taux de fuite
Leak rate
< 1.10
-8
cm
3
/sec
< 1.10
-8
cm
3
/sec
58 Av. Claude VELLEFAUX - 75010 PARIS - FRANCE
328 1/4
63
Tel : 33.(0)1.42.03.94.20 - Fax : 33.(0)1.42.03.52.85 - www.stpigroup.com
Why should we use Coway PLC chipset to develop customized PLC? (1)
The so-called customized PLC refers to the PLC created by yourself. Just think about it, would it be a great sense of accomplishment to build a PLC by yourself? But if you want to make a PLC real-time...
断琴残风 MCU
Russian training!
The Russians’ strength is not just bragging, it is also the result of real training!...
spj2007 Talking
PLC Programming (Beginners)
PLC Programming (Beginners) contributed to everyone!...
eeleader Industrial Control Electronics
When I send AT commands to the GPRS module using the HyperTerminal, there is a response (the response is also correct), but when I use a general serial port debugging tool, there is no response, only the corresponding AT command is displayed. Why?
When I send AT commands to the GPRS module using the HyperTerminal, there is a response (the response is also correct), but when I use a general serial port debugging tool, there is no response, only ...
wanghai8521 Embedded System
Issues that need attention in Verilog's signed and unsigned operations
The simplest addition, subtraction, multiplication and division operations in Verilog are actually very different for signed and unsigned numbers. Here are a few points to summarize:Example: Take the ...
eeleader FPGA/CPLD
How to save BITMAP data as JPG or BMP file
As the title says, or this is how to achieve the conversion between BMP and JPG. All of the above are under WinCE. It is best to give an example...
BlueSummer Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1843  2766  2141  662  775  38  56  44  14  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号