EEWORLDEEWORLDEEWORLD

Part Number

Search

SCM5B33

Description
Isolated True RMS Input Modules
File Size20KB,2 Pages
ManufacturerETC
Download Datasheet View All

SCM5B33 Overview

Isolated True RMS Input Modules

SCM5B33
Isolated True RMS Input Modules
FEATURES
q
INTERFACES RMS VOLTAGE (0 – 300V) OR RMS CURRENT (0 – 5A)
q
DESIGNED FOR STANDARD OPERATION WITH FREQUENCIES OF
45HZ TO 1000HZ (EXTENDED RANGE TO 20Khz)
q
COMPATIBLE WITH STANDARD CURRENT AND POTENTIAL
TRANSFORMERS
q
INDUSTRY STANDARD OUTPUTS OF EITHER 0-1MA, 0-20mA,
4-20MA, 0-5V OR 0-10VDC
q
±0.25%
FACTORY CALIBRATED ACCURACY (ACCURACY CLASS
0.2)
q
1500 VRMS CONTINUOUS TRANSFORMER BASED ISOLATION
q
INPUT OVERLOAD PROTECTED TO 480V MAX (PEAK AC & DC) OR
10A RMS CONTINUOUS
q
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
q
REGULATORY COMPLIANCE (TO BE DETERMINED)
DESCRIPTION
Each SCM5B33 True RMS input module provides a single channel of AC
input which is converted to its True RMS dc value, filtered, isolated,
amplified, and converted to a standard process voltage or current output
(Figure 1).
The SCM5B modules are designed with a completely isolated computer side
circuit which can be floated to
±50V
from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply connecting
pin 22, the Read-Enable pin to I/O Common, pin 19.
The field voltage or current input signal is processed through a pre-amplifier
and RMS converter on the field side of the isolation barrier. The converted dc
signal is then chopped by a proprietary chopper circuit and transferred across
the transformer isolation barrier, suppressing transmission of common
mode spikes and surges. The computer side circuitry reconstructs, filters and
converts the signal to industry standard outputs. Modules are powered from
+5VDC,
±5%.
For current output models an external loop supply is required having a
compliance voltage of 14 to 48VDC. Connection, with series load, is between
Pin 20 (+) and Pin 19 (-).
4
+EXC
**
AC Source +In
I
IN
–In
**
–EXC
4
6
3
5
2
1
3
Surge
Suppression
and
Protection
Pre-Amp,
Conversion
Isochopper™
Amplifier
Pat Pending
LPF
20
V
OUT or
I
OUT
*
+V
–V
19
I/O Common
Isolated
Computer-Side
Power
22
RD EN\
Backpanel
Term Block
+V
* Current Input Models Only
** Add Jumpers for Current Input Modules
(provided with SCM5B33-06, 07)
–V
17
Isolated
Field-Side
Power
Power
Oscillator
+5V
16
Power Common
FIGURE 1. SCM5B33 Block Diagram.
DATAFORTH
A Burr-Brown Company
®
Call 800-444-7644
For Information and Assistance
48
LED Drivers
Hello everyone! I have recently been interested in LED lighting, so I want to learn more about it. But I don’t know where to start, so I hope you can give me some advice....
649631964 LED Zone
How to extend the coverage distance of ZigBee network?
How to expand the coverage distance of ZigBee network? Hello everyone, I recently studied the ZigBee protocol stack and found that its routing depth is up to 15 hops, and the communication distance be...
seekbone RF/Wirelessly
Newbie help about NMI interrupt in WDT
This is the source code. Is the NMI interrupt generated by the reset button? But when the code below is run, pressing reset still activates the reset function. //**************************************...
sjwh Microcontroller MCU
How can digital quantities in SSI output mode be sent to PC via 51 single-chip microcomputer?
The existing magnetostrictive displacement sensor has a resolution of 25 bits, an RS422 interface, an SSI output mode, and wiring is clock-, clock+, data-, data+,, +24v, Gnd. How can I send this digit...
zhuweibing Embedded System
Boring! Is there anything simple I can do?
Are there any applications that are useful in wince development? I want to write them! ----------- Or, are there any small projects that can be tested with the simulator, such as system customization ...
deeply Embedded System
Based on the ucos kernel, I want to get the CPU usage of the currently running task
The platform is ARM, based on ucos-ii, and I want to get the current CPU usage and the occupancy rate of each task. It is easy to get all the currently running tasks and their priorities, but the key ...
18545862 Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1163  1303  2331  1429  706  24  27  47  29  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号