economical solution to the challenge of load-applied
harmonics mitigation in three-phase power systems.
With a plug-and-play approach and more compact
dimensions than comparable products, they can be
quickly installed and easily commissioned. They
increase the reliability and service life of electric
installations, help utilize electric sytem capacity
better, and are the key to meet Power Quality
standards such as IEEE 519. Ecosine filters reshape
your distorted current back to the desired sinusoidal
waveform. Schaffner ecosine filters can be applied to
virtually any kind of power electronics with front-end
six-pulse rectifiers, 3-phase diode or thyristor bridges,
where harmonic current distortion needs to be
reduced to defined limits.
Technical specifications
Nominal operating voltage
Operating frequency
Nominal motor drive input power rating
Total harmonic current distortion THID*
Efficiency
High potential test voltage
Protection category
Cooling
Overload capability
Ambient temperature range
3 x 440 VAC to 500 VAC ±10%
50 Hz ±1 Hz
1.1 to 250 kW
<5% at rated power
>98% for rated voltage and power
P –> E 2160 VAC (1 s)
IP 00, IP 20
Internal fan cooling or external cooling**
1.6x rated current for 1 minute, once per hour
–25°C to +45°C fully operational
+45°C to +70°C derated operation***
–25°C to +85°C transport and storage
UL 94 V-2
Filter: UL 61800-5-1, EN 61800-5-1
Chokes: EN 61558-2-20 or EN 60076-6
>200,000 hours
100 kA
TN, TT, IT
OV III (IEC 60664-1 / UL 61800-5-1)
Typical applications
Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers
Flammability corresponding to
Design corresponding to
MTBF @ 45°C/500 V (Mil-HB-217F)
SCCR****
Earthing System
Overvoltage category
****System requirements: THVD <2%, line voltage unbalance <1%
** *
Note: performance specifications in this brochure refer to six-pulse diode rectifiers.
****SCR
rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors.
THID ~5% at rated power for filter <6 kW
** Please check the inlet air flow required for cooling table on page 6 of this document.
*** I
derated
= I
nominal
*√((T
max-
T
amb
)/(T
max-
T
nominal
)) = I
nom
*√(70°C-T
amb
)/25°C
**** External UL-rated fuses required. Please consult the user manual.
2
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Filter selection table – IP 00 enclosure
Filter
Rated load power
@ 480 VAC/50 Hz
[kW]
FN 3450-1-110-E0_ _ _ _ _*
FN 3450-2-110-E0_ _ _ _ _*
FN 3450-4-112-E0_ _ _ _ _*
FN 3450-6-112-E0_ _ _ _ _*
FN 3450-8-112-E0_ _ _ _ _*
FN 3450-11-112-E0_ _ _ _ _*
FN 3450-15-113-E0_ _ _ _ _
FN 3450-19-113-E0_ _ _ _ _
FN 3450-22-113-E0_ _ _ _ _
FN 3450-30-115-E0_ _ _ _ _
FN 3450-37-115-E0_ _ _ _ _
FN 3450-45-115-E0_ _ _ _ _
FN 3450-55-115-E0_ _ _ _ _
FN 3450-75-115-E0_ _ _ _ _
FN 3450-90-116-E0_ _ _ _ _
FN 3450-110-116-E0_ _ _ _ _
FN 3450-132-118-E0_ _ _ _ _
FN 3450-160-118-E0_ _ _ _ _**
FN 3450-200-118-E0_ _ _ _ _**
FN 3450-250-118-E0_ _ _ _ _**
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
250
Motor drive
input current
[Arms]***
1.5
3
5.5
10
13
16
24
32
38
45
60
75
90
110
150
180
210
260
320
400
Rated filter
input current
[Arms]
1.35
2.75
4.99
6.77
9.24
13.6
18.5
23.3
27.0
36.9
45.4
55.2
67.5
92.5
111
135
163
198
248
310
[kg]
5.8
8.4
11.3
14.0
16.9
20.9
28.2
32.0
36.0
47.5
53.9
63.1
66.8
88.1
120.1
140.6
160.9
181.1
216.8
256.7
110
110
112
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
A
A
B
B
C
C
D
D
D
E
E
E
F
F
G
G
H
H
H
H
Weight
Terminal
Frame size
* Filter rating which does not require forced cooling or fan module
** Filter rating which does not require RC damping module for rectifiers with EMI filter
*** Motor drive input current without harmonic filter
Filter power terminals
Terminal designation*
Screw thread
Flex wire AWG
Flex wire
Screw torque value
Max width**
cable lug
[mm
2
]
110
112
113
115
116
118
M3
M4
M6
M8
M8
M10
14-22
10-22
6-18
1/0-8
3/0-8
3/0-500 kcmil
0.4-2.5
0.4-6
0.75-16
10-50
10-95
95-240
[Nm]
0.5
1.2
3
8
8
10
[mm]
7
10
15
15
17
35
A
B, C
D
E, F
G
H
Frame size
* Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 118
** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must
be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided.
Filter signal and earth terminals
Terminal type
Screw thread
Screw torque value
[Nm]
Signal
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
M3*
M5
M6
M6
M8
M8
M10
M10
M10
0.5
4
8
8
14
14
25
25
25
All
A
B
C
D
E
F
G
H
Frame size
* Max width cable lug = 7 mm
3
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Filter selection table – IP 20 enclosure
Filter
Rated load power
@ 480 VAC/50 Hz
[kW]
FN 3450-1-110-E2_ _ _ _ _*
FN 3450-2-110-E2_ _ _ _ _*
FN 3450-4-112-E2_ _ _ _ _*
FN 3450-6-112-E2_ _ _ _ _*
FN 3450-8-112-E2_ _ _ _ _*
FN 3450-11-112-E2_ _ _ _ _*
FN 3450-15-113-E2_ _ _ _ _
FN 3450-19-113-E2_ _ _ _ _
FN 3450-22-113-E2_ _ _ _ _
FN 3450-30-115-E2_ _ _ _ _
FN 3450-37-115-E2_ _ _ _ _
FN 3450-45-115-E2_ _ _ _ _
FN 3450-55-115-E2_ _ _ _ _
FN 3450-75-115-E2_ _ _ _ _
FN 3450-90-116-E2_ _ _ _ _
FN 3450-110-116-E2_ _ _ _ _
FN 3450-132-118-E2_ _ _ _ _
FN 3450-160-118-E2_ _ _ _ _**
FN 3450-200-118-E2_ _ _ _ _**
FN 3450-250-118-E2_ _ _ _ _**
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
250
Motor drive
input current
[Arms]***
1.5
3
5.5
10
13
16
24
32
38
45
60
75
90
110
150
180
210
260
320
400
Rated filter
input current
[Arms]
1.35
2.75
4.99
6.77
9.24
13.6
18.5
23.3
27.0
36.9
45.4
55.2
67.5
92.5
111
135
163
198
248
310
[kg]
7
9
13
15
19
23
32
36
40
53
60
69
74
95
129
149
178
198
234
274
110
110
112
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
A
A
B
B
C
C
D
D
D
E
E
E
F
F
G
G
H
H
H
H
Weight
Terminal
Frame size
* Filter rating which does not require forced cooling or fan module
** Filter rating which does not require RC damping module for rectifiers with EMI filter
*** Motor drive input current without harmonic filter
Filter power terminals
Terminal designation*
Screw thread
Flex wire AWG
Flex wire
Screw torque value
Max width**
cable lug
[mm
2
]
110
112
113
115
116
118
M3
M4
M6
M8
M8
M10
14-22
10-22
6-18
1/0-8
3/0-8
3/0-500 kcmil
0.4-2.5
0.4-6
0.75-16
10-50
10-95
95-240
[Nm]
0.5
1.2
3
8
8
10
[mm]
7
10
15
15
17
35
A
B, C
D
E, F
G
H
Frame size
* Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 118
** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must
be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided.
Filter signal and earth terminals
Terminal type
Screw thread
Screw torque value
[Nm]
Signal
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
M3*
M5
M6
M6
M8
M8
M10
M10
M10
0.5
4
8
8
14
14
25
25
25
All
A
B
C
D
E
F
G
H
Frame size
* Max width cable lug = 7 mm
4
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Product selector
Table 1: Filter configurations if external air flow is available for cooling
(Filters do
not contain fan
and do
not contain aux. power supply)
E0XXXXX
- For rectifiers without DC-link
choke
E0XXJXX
- For rectifiers without DC-link
choke
- Filters contain trap disconnect
jumper
E0XXXRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain RC damper
module
E0XXJRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain RC damper
module and trap disconnect
jumper
5
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Table 2: Filter configurations with embedded ventilation
(Filters
contain fan
and
aux. power supply)
E0FAXXX and E2FAXXX
- For rectifiers without DC-link
choke
- Filters contain fan, aux. power
supply
E0FAJXX and E2FAJXX
- For rectifiers without DC-link
choke
- Filters contain fan, aux. power
supply and trap disconnect
jumper
E0FAXRX and E2FAXRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain fan, aux. power
supply and RC damper module
E0FAJRX and E2FAJRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain fan, aux. power
supply, RC damper module and
trap disconnect jumper
Table 3: Filter configurations if external aux. power supply for the fan is available
Hello everyone, I'm here again. I read the 6-axis data of LSM6DSL on the previous board. Then I found that my acceleration data can be read but my angular velocity data can't be read.Then I changed to...
After two days of continuous searching and experimentation, I finally made a breakthrough. The problem of the triode not working when Proteus simulates the dynamic scanning of the digital tube is solv...
YC development board handwriting development, I need to implement the full-screen handwriting function. The method I got so far is to write a touch screen driver by myself. Because the system itself h...
Is anyone using the STM32L152 series MCU? I want to ask a question. I want to do low power consumption now, so I need to enter Stop mode. But I read a book and it says that entering Stop mode will tur...
c=sizeof(USB_CONFIGURATION_DESCRIPTOR) + sizeof(USB_INTERFACE_DESCRIPTOR) + (NUM_ENDPOINTS * sizeof(USB_ENDPOINT_DESCRIPTOR));If you write it like this on the IAR compiler, an error will be reported. ...
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
Microcontrollers (MCUs), which are widely used in automotive electronics, are rapidly facing time and cost pressures. The main advantage of using MCUs has always been to create high-level system in...[Details]
With the continuous improvement of the requirements of intelligent building security systems and the continuous improvement of people's safety awareness, indoor anti-theft has gradually attracted peop...[Details]
1 Introduction
As an emerging microfabrication technology, micro-electromechanical system (MEMS) technology has begun to be applied in various fields. It can integrate functions such as inform...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
Flooded Batteries
This battery developed in Germany can be used to power flashlights, strobe lights and toys as long as it is filled with water. This battery can be stored for 50 years and can...[Details]
Introduction
Liquid crystal, as a display device, is widely used in low-power products such as instruments, meters, and electronic equipment with its unique advantages. In the past, the displ...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
LED technology has made rapid progress, and improvements in chip design and materials have promoted the development of brighter and more durable light sources, and the scope of light source applica...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
Temperature compensated quartz crystal oscillator (TCXO) is widely used as a high-precision frequency source in communication systems, radar navigation systems, precision measurement and control sy...[Details]