EEWORLDEEWORLDEEWORLD

Part Number

Search

ATH10T05-9S

Description
DC-DC Regulated Power Supply Module, 1 Output, 55W, Hybrid
CategoryPower/power management    The power supply circuit   
File Size1MB,2 Pages
ManufacturerVertiv
Download Datasheet Parametric View All

ATH10T05-9S Overview

DC-DC Regulated Power Supply Module, 1 Output, 55W, Hybrid

ATH10T05-9S Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerVertiv
Reach Compliance Codeunknown
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage5.5 V
Minimum input voltage4.5 V
Nominal input voltage5 V
JESD-30 codeR-XDMA-X10
JESD-609 codee0
Number of functions1
Output times1
Number of terminals10
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum output voltage3.6 V
Minimum output voltage0.8 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelINDUSTRIAL
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output55 W
Fine-tuning/adjustable outputYES
Base Number Matches1
10Amps
ATH10
PRELIMINARY
Total Power:
Input Voltages:
No. of Outputs:
55W
3.3V, 5V, 12V
Single
Electrical Specs
Input
Input Range
3.0 - 3.6V
4.5 - 5.5V
10.8 - 13.2V
Under Voltage Lockout with hysterisis
Efficiency
up to 92%
Output
Overall Regulation
Noise/Ripple
Remote sense
Transient Response
1% of Vo Typ
30mV Typ (2.5Vo and below)
1% Vo Typ (Vo > 2.5V)
Up to 300mV max
100mV typical for 3.3Vo
for 50% to 100% I
O,MAX
step change
70us recovery time (Co = 330uF)
175% I
O,MAX
typical (autorecovery)
Special Features
Point-of-Load Alliance product
Open frame TH or SMT termination
Auto-Track™ Sequencing
Margin Up/Down Controls
Remote sense compensation
Output Voltage Adjust (Resistor Programming)
Under Voltage Lockout
Pre-Biased start-up
2
Output On/Off Inhibit
-40°C to +85°C Ambient Air Operation
Non Isolated module
Over Current Protection
Control
Inhibit On/Off
Output Voltage Adjust
Output Margin
Output Auto-Track™
Positive Enable Logic
See output range on page 2
±5% V
O,NOM
(See Note 5)
Environmental
Ambient air operating temperature range:
-40°C to +85°C
Storage temperature: -40°C to +125°C
Calculated MTBF: > TBA
Specifications subject to change without notice
Safety
UL,cUL 60950 Recognition (Pending)
EN 60950 through TUV or VDE (Pending)
2
North America (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211Asia (HK): 852-2437-9662

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2728  75  537  182  2004  55  2  11  4  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号