38-M126F4

Description
POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size232KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

38-M126F4 Overview

POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT

38-M126F4 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 305 V, COIL RELEASE VOLTAGE(AC): 60 V
body width46.2 mm
body height51.6 mm
Body length or diameter46.2 mm
Coil current (AC) maximum value0.03 A
Coil power5000 mW
Coil resistance15200 Ω
Maximum coil voltage (AC)452 V
Coil/Input Power TypeAC
Contact/Output Power TypeAC
Electrical life250000 Cycle(s)
Manufacturer's serial number38
Installation featuresPANEL MOUNT
physical size46.2mm X 46.2mm X 51.6mm
GuidelineUL
Relay actionMOMENTARY
Relay functionSPST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeQUICK CONNECT
Base Number Matches1
Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
38
series
Potential Motor Starting Relay
1-pole, 35A, Normally Closed
AC Coil
File E83865
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Single-pole, normally closed relay used extensively in HVAC applications.
• Variety of mounting positions and brackets.
• Convenient 0.250” (6.35 mm) quick connect terminals.
• Custom-built to meet customer requirements.
Coil Data @ 25°C
Voltage:
130, 170, 214, 256, 336, 395, 420 and 495 VAC, 60 Hz.
Nominal Sealed Power:
5 VA).
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Data @ 25°C
Arrangements:
Normally-Closed.
Materials:
Silver cadmium oxide.
Maximum Rating:
35A inductive @ 277VAC, 0.5 power factor (Break only.)
Expected Life:
750,000 ops, mechanical.
250,000 ops., breaking rated load.
Mechanical Data
Termination:
0.250” (6.35 mm) quick connects (single or dual, model
dependent). Terminals #4 & #6 are dummies for customer
convenience.
Mounting Position:
Each model is calibrated for its specified mounting
position. Pick-up voltage may vary if relay is mounted
in positions other than specified.
Weight:
5.76 oz. (163.8 g) approximately
Initial Dielectric Strength
Initial Breakdown Voltage:
1,554 VAC @ 60 Hz. between live parts and
exposed non-current carrying metal parts.
Ordering Information
Typical Part No.
B
38
-A
144
C
3
000
1. Series:
38 = 1-pole, normally-closed, potential motor starting relay
2. Wiring and Terminal Type (number of QCs at given base locations):
A = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 2 @ loc. 6.
D = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
M = 2 @ loc. 1, 2 @ loc. 2, 2 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
R = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 1 @ loc. 5 and 0 @ loc. 6.
S = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
T = 2 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
Y = 1 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
3. Coil Rating and Calibration:
000-999 = See table on following page for details.
4. Mounting Bracket Style:
C, D, F or J = See drawings below for details.
C
1.59
(40.39)
#8-32
UNC-2B THD.
D
F
J
.500
(12.7)
#8-32
UNC-2B THD.
1.00
(25.4)
1.563
(39.7)
5. Mounting Position:
1, 2, 3, 4, 5 & 6 = See drawings below for details. NOTE: Devices calibrated in specified mounting position only.
1
2
3
4
5
6
6. Customer ID Suffix:
000-999 = Factory assigned customer ID
Standard part numbers listed below are more likely to be available from stock.
Custom parts only.
Dimensions are shown for
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
818
reference purposes only.
Op Amp Noise Gain: More Than Just Noise
For ease of understanding, output noise (including offset) is usually referenced to the inputs of the op amp or amplifier. In general, an output voltage of a given polarity referenced entirely to the ...
fish001 Analogue and Mixed Signal
Error in MAKEIMAGE, please help
I want to port a com test program (from ARM platform to x86 platform), the compilation platform used is pb4.2 and evc4.0. After the source code (MFC program) is compiled, it can run normally on the ar...
u0no1 Embedded System
ST motor vector variable frequency drive control demo board IFN003V1 PCB blank board
[color=#444444][font=Tahoma,] I provide several ST motor vector variable frequency drive control demo boards IFN003V1 [color=#4298ba]PCB[/color] empty boards. This is a personal act, not for commercia...
quanmujiang stm32/stm8
MSO430 reset circuit - funny explanation version
[size=4] What's so good about the reset circuit?[/size] [size=4] Many people may think so. I believe that everyone knows how to use a simple RC reset. I have always thought so. Later, I saw the reset ...
Aguilera Microcontroller MCU
The C16F73 microcontroller has operating modes such as HS, XT, etc. Does it require program settings to select that mode?
The C16F73 microcontroller has two operating modes: HS, XT, etc. Do I need to set the program to select the mode? Or do I just need to select the corresponding peripheral circuit?...
woinwow Embedded System
【Design Tools】 Demonstrate how to use ISE to develop FPGA projects (2)
[flash]http://player.youku.com/player.php/sid/XMTk5NDQ1NzUy/v.swf[/flash]...
鑫海宝贝 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 469  1684  1965  2876  718  10  34  40  58  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号