EEWORLDEEWORLDEEWORLD

Part Number

Search

206-312RA

Description
Slide Dip Switch, 2 Switches, 3PST, Latched, 0.05A, 24VDC, Solder Terminal, Through Hole-right Angle, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size731KB,5 Pages
ManufacturerCTS
Environmental Compliance
Download Datasheet Parametric View All

206-312RA Online Shopping

Suppliers Part Number Price MOQ In stock  
206-312RA - - View Buy Now

206-312RA Overview

Slide Dip Switch, 2 Switches, 3PST, Latched, 0.05A, 24VDC, Solder Terminal, Through Hole-right Angle, ROHS COMPLIANT

206-312RA Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time4 weeks
body width7.24 mm
body height10.16 mm
Body length or diameter17.42 mm
Maximum contact current (DC)0.05 A
Contact (DC) maximum rated R load.05A@24VDC
Maximum contact voltage (DC)24 V
Electrical life10000 Cycle(s)
JESD-609 codee4
Manufacturer's serial number206RA
Installation featuresTHROUGH HOLE-RIGHT ANGLE
Number of switching segments2
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
method of packingANTI-STATIC TUBE
surface mountNO
Switch actionLATCHED
switch function3PST
Switch typeSLIDE DIP SWITCH
Terminal surfaceGold (Au)
Termination typeSOLDER
Base Number Matches1
Series 206/208
Through-Hole DIP Switch
Available with SPST, SPDT, DPST, 3PST circuitry choices
Available with low profile, standard, or extended actuator heights.
Consult the ordering information for options.
RoHS compliant
Optional top tape seal for board spray washing
Description
The terminals are molded into the thermoset base and provide an electrostatic discharge shield rating to 22KV
when the OFF side terminals are connected to ground. The optimized contact design incorporating a dimple-to-
flat surface wiping interface provides long-term contact corrosion resistance making this the ideal choice for any
HVAC, server, or security system.
Ordering Information
Series
206-/208 -
20212124
1
Number of
Poles
1
Number of B Number of
Throws S Switch Positions
2
2
1
Actuator
Height
E
E
Bottom
Epoxy Seal
S
Top Tape
Seal
T
Actuation
Preset
N
1
Code
Blank
1
2
3
No. of poles
For SPST
Single pole
Double pole
3 poles
Code No. of switch
positions
1
2
3
4
5
6
7
8
9
10
12
1 position
2 positions
3 positions
4 positions
5 positions
6 positions
7 positions
8 positions
9 positions
10 positions
12 positions
Code
Blank
E
LP
Spec.
Standard (0.89mm/.035”)
Extended (3.43mm/.135”)
(SPST only)
Low profile (Flush)
(SPST & SPDT only)
Code
BLANK
N
Spec.
Ship at OFF position
Ship at ON position
(SPST, DPST & 3PST
only)
Code
Blank
1
2
Spec.
For SPST
Single throw
Double throw
Code
Code
Blank
S
Top tape seal
No top tape seal
Top tape seal
(Not available for
extended actuator
or 1-position SPST
DIP switch)
Bottom epoxy seal
No epoxy seal
Epoxy seal
(Required for 206-1S)
Blank
T
Notes: 1.Contact CTS for other common features not listed.
2. Alternate numbering format 20600/20800… instead of 206-/208-
Example: 206008ST
2017-08-17 Rev. C
Page 1 of 5
© 2017 CTS® Corporation. Information/product(s) subject to change. No warranty that product(s) will meet the stated specifications for customer specific applications or test
equipment. Visit www.ctscorp.com for list of applicable patent(s), more information, or to request a quote.
The world is still a simulation
Engineers at Analog Devices rigorously test amplifiers, converters, and RF devices to ensure that consumer and industrial products work properly.   Many people say, “We live in a digital world,” but y...
frozenviolet Automotive Electronics
About the UART programming problem of msp430
1 Related knowledge MSP430 series, the baud rate value setting of the usart module is determined by the following three parameters: UxBR0, UxBR1, UxMCTL Baud rate = BRCLK/N BRCLK: clock source, which ...
Aguilera Microcontroller MCU
Power Detection Idea - Software Schmitt Trigger
[size=4]Where does the problem come from? [/size] [size=4] [/size] [size=4] Many friends who are engaged in electronics will basically encounter the use of MCU's ADC to collect voltage to monitor powe...
Aguilera Analogue and Mixed Signal
Part-time job: Looking for experienced people to write books on PIC/AVR microcontrollers
We have a selection of books on PIC and AVR microcontrollers, and we are looking for authors who are interested in writing books. The author must have rich practical experience and writing resources, ...
你是最美 Microchip MCU
Some confusion about mini2440 NAND Flash
I saw a post on OURAVR discussing MINI2440. I also have some questions, so I'm going to ask everyone: 1. When the system is restarted from NAND Flash, who moves the front part of the NAND Flash data t...
fish001 Embedded System
A very good serial port program
//PC reads MCU instruction structure: (interrupt mode, ASCII code representation) //Frame: Frame header flag|Frame type|Device address|Start address|Length n|Checksum|Frame tail flag//Value: 'n' 'y'| ...
songbo MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2568  2755  1482  947  1019  52  56  30  20  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号