Chooses reference between SYNC (0) & SYNC (1). (Refer to functional block diagram).
Selects between
÷
1 and
÷
2 frequency options. (Refer to functional block diagram).
Feedback input to phase detector.
Input for external loop filter connection.
Clock output.
Inverted clock output.
Clock output (2 x Q frequency).
Clock output (Q frequency
÷
2).
Indicates phase lock has been achieved (HIGH when locked).
Asynchronous reset (active LOW) and output enable (active HIGH). When HIGH, outputs are
enabled. When LOW, outputs are in HIGH impedance.
Disables phase-lock for low frequency testing. (Refer to functional block diagram).
3052 tbl 01
Description
Q5
2Q
Q/2
LOCK
OE/
RST
PLL_EN
9.8
2
IDT54/74FCT388915T 70/100/133/150
3.3V LOW SKEW PLL-BASED CLOCK DRIVER
MILITARY AND COMMERCIAL TEMPERATURE RANGES
ABSOLUTE MAXIMUM RATINGS
(1)
Symbol
Rating
V
TERM(2)
Terminal Voltage
with Respect to
GND
V
TERM(3)
Terminal Voltage
with Respect to
GND
(4)
Terminal Voltage
V
TERM
with Respect to
GND
T
A
Operating
Temperature
T
BIAS
Temperature
Under Bias
T
STG
Storage
Temperature
I
OUT
DC Output
Current
Commercial
Military
–0.5 to +4.6 –0.5 to +4.6
Unit
V
CAPACITANCE
(T
A
= +25°C, f = 1.0MHz)
Symbol
Parameter
(1)
C
IN
Input
Capacitance
C
OUT
Output
Capacitance
Conditions
V
IN
= 0V
V
OUT
= 0V
Typ.
4.5
5.5
Max. Unit
6.0
pF
8.0
pF
3052 lnk 03
–0.5 to +7.0
–0.5 to +7.0
V
NOTE:
1. This parameter is measured at characterization but not tested.
–0.5 to V
CC
+0.5
0 to +70
–55 to +125
–55 to +125
–60 to +60
–0.5 to V
CC
+0.5
–55 to +125
–65 to +135
–65 to +150
–60 to +60
V
°C
°C
°C
mA
3052 tbl 02
NOTES:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RAT-
INGS may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating conditions for ex-
tended periods may affect reliability.
2. Vcc terminals.
3. Input terminals.
4. Output and I/O terminals.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Commercial: T
A
= 0°C to 70°C, V
CC
= 3.3V
±0.3V
Symbol
V
IH
V
IL
I
I H
I
I L
I
OZH
I
OZL
V
IK
I
ODH
I
ODL
V
OH
V
OL
V
H
I
CCL
I
CCH
I
CCZ
Parameter
Input HIGH Level
Input LOW Level
Input HIGH Current
Input LOW Current
High Impedance Output Current
(3-State Output Pins)
Clamp Diode Voltage
Output Drive Current
Output Drive Current
Output HIGH Voltage
Output LOW Voltage
Input Hysteresis
Quiescent Power Supply Current
V
CC
= Max.
Test Conditions
(1)
Guaranteed Logic HIGH Level
Guaranteed Logic LOW Level
V
CC
= Max.
V
I
= 5.5V
V
I
= GND
V
O
= V
CC
V
O
= GND
V
CC
= Min., I
IN
= –18mA
V
CC
= Max., V
IN
= V
IH
or V
IL
, V
O
= 1.5V
(3)
V
CC
= Max., V
IN
= V
IH
or V
IL
, V
O
= 1.5V
(3)
V
CC
= Min.
V
CC
= Min.
—
V
CC
= Max., V
IN
= GND or V
CC
(Test mode)
I
OH
= –16mA
I
OL
= 32mA
Min.
2.0
–0.5
—
—
—
—
—
–36
50
2.4
(5)
—
—
—
Typ.
(2)
—
—
—
—
—
—
–0.7
—
—
3.0
0.3
100
2.0
Max.
5.5
0.8
±1
±1
±1
±1
–1.2
—
—
—
0.5
—
4.0
Unit
V
V
µA
µA
µA
µA
V
mA
mA
V
V
mV
mA
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at V
CC
= 3.3V, +25°C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. This parameter is guaranteed but not tested.
5. V
OH
= V
CC
- 0.6V at rated current.
3052 tbl 04
9.8
3
IDT54/74FCT388915T 70/100/133/150
3.3V LOW SKEW PLL-BASED CMOS CLOCK DRIVER
MILITARY AND COMMERCIAL TEMPERATURE RANGES
POWER SUPPLY CHARACTERISTICS
Symbol
∆I
CC
I
CCD
C
PD
I
C
Parameter
Quiescent Power Supply Current
TTL Inputs HIGH
Dynamic Power Supply
Current
(4)
Power Dissipation Capacitance
Total Power Supply Current
(6)
V
CC
= Max.
V
IN
=
V
CC
–2.1V
(3)
V
IN
= V
CC
V
IN
= GND
—
—
—
0.2
15
30
0.3
25
60
mA/
MHz
pF
mA
V
CC
= Max.
All Outputs Open
50% Duty Cycle
V
CC
= Max.
PLL_EN = 1, LOCK = 1, FEEDBACK = Q4
SYNC frequency = 50MHz. All bits loaded with
15pF
V
CC
= Max.
PLL_EN = 1, LOCK = 1, FEEDBACK = Q4
SYNC frequency = 50MHz. All bits loaded with
50Ω Thevenin termination and 20pF
3052 tbl 05
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at V
CC
= 3.3V, +25°C ambient.
3. Per TTL driven input. All other inputs at V
CC
or GND.
4. This parameter is not directly testable, but is derived for use in Total Power Supply Calculations. It is derived with Q frequency as the reference.
5. Values for these conditions are examples of the I
CC
formula. These limits are guaranteed but not tested.
6. I
C
= I
QUIESCENT
+ I
INPUTS
+ I
DYNAMIC
I
C
= I
CC
+
∆I
CC
D
H
N
T
+ I
CCD
(f) + I
LOAD
I
CC
= Quiescent Current (I
CCL
,
I
CCH
and I
CCZ
)
∆I
CC
= Power Supply Current for a TTL High Input (V
IN
= 3.4V)
D
H
= Duty Cycle for TTL Inputs High
N
T
= Number of TTL Inputs at D
H
I
CCD
= Dynamic Current Caused by an Input Transition Pair (HLH or LHL)
f =2Q Frequency
I
LOAD
= Dynamic Current due to load.
Test Conditions
(1)
V
IN
= V
CC
–0.6V
(3)
Min.
—
Typ.
(2)
2.0
Max.
30
Unit
µA
—
90
120
mA
SYNC INPUT TIMING REQUIREMENTS
Symbol
Parameter
T
RISE/FALL
Rise/Fall Times,
SYNC inputs
(0.8V to 2.0V)
Frequency Input Frequency,
SYNC Inputs
Duty Cycle Input Duty Cycle,
SYNC Inputs
Min.
—
Max.
3.0
Unit
ns
10.0
(1)
25%
2Q fmax
75%
MHz
—
3052 tbl 06
OUTPUT FREQUENCY SPECIFICATIONS
Max.
Symbol
f2Q
fQ
fQ/2
Parameter
Operating frequency 2Q Output
Operating frequency Q0-Q4,
Q
5 Outputs
Operating frequency Q/2 Output
Min.
40
20
10
70
70
35
17.5
100
100
50
25
(2)
133
133
66.7
33.3
150
150
75
37.5
Unit
MHz
MHz
MHz
3052 tbl 07
NOTES:
1. Note 7 in "General AC Specification Notes" and Figure 3 describes this specification and its actual limits depending on the feedback connection.
2. Maximum operating frequency is guaranteed with the part in a phase locked condition and all outputs loaded.
9.8
4
IDT54/74FCT388915T 70/100/133/150
3.3V LOW SKEW PLL-BASED CLOCK DRIVER
MILITARY AND COMMERCIAL TEMPERATURE RANGES
SWITCHING CHARACTERISTICS OVER OPERATING RANGE
Symbol
t
RISE/FALL
All Outputs
t
PULSE WIDTH (3)
Q,
Q
, Q/2 outputs
(3)
t
PULSE WIDTH
2Q Output
(3)
Parameter
Rise/Fall Time
(between 0.8V and 2.0V)
Output Pulse Width
Q0-Q4,
Q
5, Q/2, @ 1.5V
Output Pulse Width
2Q @ 1.5V
Load = 50Ω to
V
CC
/2, C
L
= 20pF
0.1µF from LF to
Analog GND
(5)
Load = 50Ω to
V
CC
/2, C
L
= 20pF
Condition
(1)
Load = 50Ω to
V
CC
/2, C
L
= 20pF
Min.*
0.2
(2)
Max.*
1.5
0.5t
CYCLE
+ 0.5
(5)
0.5t
CYCLE
+ 0.7
(5)
+0.5
Unit
ns
ns
ns
ns
Load = 50Ω to
0.5t
CYCLE
– 0.5
(5)
V
CC
/2, C
L
= 20pF
0.5t
CYCLE
– 0.7
(5)
–0.5
SYNC input to FEEDBACK delay
t
PD
(3)
(measured at SYNC0 or 1 and FEEDBACK
SYNC-FEEDBACK
input pins)
t
SKEW
r
(rising)
(3,4)
t
SKEW
f
(falling)
(3,4)
t
SKEW
all
t
LOCK (6)
(3,4)
Output to Output Skew
between outputs 2Q, Q0-Q4,
Q/2 (rising edges only)
Output to Output Skew
between outputs Q0-Q4 (falling edges only)
Output to Output Skew
2Q, Q/2, Q0-Q4 rising,
Q
5 falling
Time required to acquire
Phase-Lock from time
SYNC input signal is received
Output Enable Time
OE/
RST
(LOW-to-HIGH) to Q, 2Q, Q/2,
Q
Output Disable Time
OE/
RST
(HIGH-to-LOW) to Q, 2Q, Q/2,
Q
—
250
ps
—
—
1
(2)
250
350
10
ps
ps
ms
t
PZH
t
PZL
t
PHZ
t
PLZ
3
(2)
3
(2)
14
14
ns
ns
3052 tbl 08
GENERAL AC SPECIFICATION NOTES:
* PRELIMINARY.
1. See test circuit and waveforms.
2. Minimum limits are guaranteed but not tested.
3. These specifications are guaranteed but not production tested.
4. Under equally loaded conditions, as specified under test conditions and at a fixed temperature and voltage.
5. t
CYCLE
= 1/frequency at which each output (Q,
Q
, Q/2 or 2Q) is expected to run.
6. With V
CC
fully powered-on and an output properly connected to the FEEDBACK pin. t
After learning how to operate LED and KEY , I turned my attention to the serial port, which is also often encountered in development and debugging. The serial port is still the most commonly used debu...
I have suffered from the Chinese path of the Chinese system of Windows and the Chinese name of the computer. So when I installed Ubuntu, it was an English version. But it was really inconvenient to se...
Design of a regenerative braking control circuit Abstract: A design method for a pump-up voltage control circuit is presented to regenerate energy back to the grid. The main circuit, control circuit, ...
Starting from today, I think learning something requires systematic planning. After learning something, you need to summarize it, and then integrate it and make it into a project. This is called learn...
: This paper discusses the transformation of the power supply of the centralized inverter control system in the polyester industrial production process. The system uses the Intel MCS251 series single-...
In passthru, part of the code is as follows: int PacketSize; PUCHAR pPacketContent; PUCHAR pBuf; UINT BufLength; NdisQueryPacket(MyPacket,NULL,NULL,NULL,&PacketSize); NdisAllocateMemory(&pPacketConten...
Hardware designers have begun to adopt FPGA technology in high-performance DSP designs because it can provide 10-100 times faster computing than PC-based or microcontroller-based solutions. Previou...[Details]
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
introduction
In the discharge process of tokamak plasma physics, the study of rupture and sawtooth is of great significance. Rupture and sawtooth exist in most tokamaks. Rupture is a notew...[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
Instrument stepper motor
The stepper motor is an open-loop control element that converts electrical pulse signals into angular displacement or linear displacement. In the case of non...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
1 Introduction
Intelligent control instruments are one of the most commonly used controllers in industrial control. They are mainly aimed at a specific parameter (such as pressure, tempera...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
hint:
The number of speakers and their spacing limit the sound field of a portable stereo system.
Spatial audio attempts to artificially recreate the experience of listening to sounds i...[Details]
With the widespread application of new services and technologies in the communications industry, the scale and capacity of operators' network construction are getting larger and larger, and the ris...[Details]
1 Basic Features
In computer control systems and various intelligent instruments and meters composed of single-chip microcomputers (or microprocessors), various external analog signals must be ...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
Temperature compensated quartz crystal oscillator (TCXO) is widely used as a high-precision frequency source in communication systems, radar navigation systems, precision measurement and control sy...[Details]
introduction
When it comes to the production of mobile phone lithium-ion batteries, the first thing that comes to mind is Japan's industrialized mechanical assembly line, NOKIO, MOTOLROLA's st...[Details]