EEWORLDEEWORLDEEWORLD

Part Number

Search

56.44.9.012.4038

Description
Electromechanical Relay, 4PDT, 13.2VDC (Coil), 1.3W@12VDCmW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.44.9.012.4038 Overview

Electromechanical Relay, 4PDT, 13.2VDC (Coil), 1.3W@12VDCmW (Coil), Random, AC/DC Output

56.44.9.012.4038 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width27.7 mm
body height37.1 mm
Body length or diameter40.8 mm
Coil operating voltage (DC)10.2 V
Coil power1300 mW
Coil resistance123 Ω
Maximum coil voltage (DC)13.2 V
Nominal coil voltage12 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Tin Oxide
Input switching control typeRandom
Number of terminals14
operating hours10 ms
PCB hole count14
physical size40.8mm x 27.7mm x 37.1mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay function4PDT
release time4 ms
Terminal length0.0043 inch
Termination typeSOLDER
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
Is there any LM1117 series that can provide negative pressure?
Does the LM1117 series have a negative voltage? I have a few questions: 1. Is the 1117 series an LDO? 2. Does the LM1117 series have a negative voltage? I don't know much about LDO. 3. I don't know mu...
liweiliang Power technology
About DC voltage isolation sampling
Now we need to isolate and sample the 0-25V DC voltage with an accuracy requirement of 1%. Due to the price of the Hall voltage sensor It’s quite high, I hope to change to other isolation sampling met...
lei619lei Analog electronics
[Raspberry Pi Pico Review] CoreMark program porting, test running points
CoreMark is needless to say, you can search it on Baidu. In short, it is just like AnTuTu, the higher the score, the higher the performance of the microcontroller. Using the C/C++ development environm...
dql2016 Creative Market
Several power supply interview questions (from my own test)
Reprinted from: http://forum.powersystems.eet-cn.com/BLOG_ARTICLE_6743.HTM?click_from=8800073982,9523571682,2011-03-04,PSCOL,FORUM_ALERTclick_from==etsd 1. Generally speaking, compared with a linear p...
安_然 Analog electronics
What cool AR technologies are around you? Where else do you think AR technology can be used?
[p=28, null, left]This year, Northwestern Polytechnical University issued the first AR college entrance examination admission notice in the country to its freshmen, which not only made AR technology p...
eric_wang Talking
[TI mmWave Radar Evaluation]_4_AWR1843BOOST Corridor Ranging Test
Series of posts: 1. AWR1843BOOST unboxing 2. Use of AWR1843BOOST 3. AWR1843BOOST corridor ranging value test environmentThe previous article has analyzed the test environment. This time, we use an iro...
lbbook TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development