EEWORLDEEWORLDEEWORLD

Part Number

Search

8531K19

Description
Toggle Switch, DP3T, Momentary, 18A, 28VDC, Screw Terminal, Lever Actuator, Panel Mount-threaded
CategoryMechanical and electronic products    switch   
File Size68KB,1 Pages
ManufacturerEaton
Download Datasheet Parametric View All

8531K19 Overview

Toggle Switch, DP3T, Momentary, 18A, 28VDC, Screw Terminal, Lever Actuator, Panel Mount-threaded

8531K19 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeLEVER
body width22.6 mm
body height34.1 mm
Body length or diameter33.5 mm
Contact (AC) maximum rated R load11A@115VAC
Maximum contact current (AC)11 A
Maximum contact current (DC)18 A
Contact (DC) maximum rated R load18A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Electrical life50000 Cycle(s)
Installation featuresPANEL MOUNT-THREADED
Maximum operating temperature66 °C
Minimum operating temperature-46 °C
sealENVIRONMENTALLY SEALED; IP68
surface mountNO
Switch actionMOMENTARY
switch functionDP3T
Switch typeTOGGLE SWITCH
Termination typeSCREW
Base Number Matches1
Series - 8530, 8531, 8532
FEATURES
Environmentally sealed
1, 2 and 4 pole Circuitry
One hole mounting for easy
installation
Multi-circuits
2 & 3 position with maintained
and momentary action
Three types of termination
offered as standard
INDUSTRIAL - ENVIRONMENTALLY SEALED SWITCHES
Econoswitch Sealed Toggle Switches
SPECIFICATIONS
CURRENT RATINGS
No. of
Poles
Catalog
Number
Type of
Operation
Lamp
Load
5
4
7
5
5
4
28VDC
Resistive Inductive
Load
Load
20
15
15
10
20
15
18
10
20
12
18
10
115VAC
60 or 400Hz
Lamp
Resistive Inductive
Load
Load
Load
3
15
10
2
11
7
4
15
15
2
11
8
4
15
15
2
11
8
Watertight seal per MIL-STD-108E
and designed to meet IP68
UL recognized and CSA certified
Three standard types of terminals:
Screw
6-32 UNC-2A
Solder lug .125 [3,17] dia. hole
Spade
.250 [6,35] x .032
[0,81] thick
Life: 50,000 operations at rated load.
100,000 operations mechanical life.
Temperature Range: -50°F to +150°F
(-46°C to + 66°C)
Maintained
Momentary
2
8531
Maintained
Momentary
4
8532
Maintained
Momentary
For the UL/CSA ratings, see page A70.
1
8530
STANDARD LEVER SELECTION TABLE
CIRCUIT WITH LEVER IN . . .
Up
Position
Center
Position
Down Position
(Keyway)
Screw
Terminals
Solder Lug
Terminals
Spade
Terminals
CATALOG NUMBER
ONE POLE
8530
ON
ON
ON
ON
ON
ON
ON
*
NONE
ON
OFF
ON
ON
*
ON
ON
ON
ON
ON
ON
ON
ON
*
NONE
ON
OFF
ON
ON
*
ON
ON
ON
ON
*
ON
ON
ON
*
ON
ON
ON
ON
ON
ON
*
ON
NONE
ON
OFF
ON
*
ON
ON
ON
ON
*
ON
OFF
NONE
NONE
OFF
OFF
*
NONE
OFF
OFF
NONE
NONE
OFF
ON
ON
ON
OFF
ON
NONE
NONE
ON
*
ON
*
ON
*
OFF
*
ON
*
ON
*
NONE
NONE
ON
OFF
ON
NONE
NONE
ON
*
ON
*
ON
*
OFF
*
ON
*
ON
*
NONE
NONE
ON
ON
*
ON
*
ON
ON
*
ON
*
ON
OFF
ON
NONE
NONE
ON
*
ON
*
ON
*
OFF
*
ON
*
ON
*
NONE
NONE
ON
ON
*
ON
*
8530K1
K9
K4
K6
K8
8530K5
K2
K7
K10
K11
8530K3
K12
K13
8531K1
K9
K4
K6
K8
8531K5
K2
K7
K10
K11
8531K3
K12
K13
K14
K15
8531K16
K17
K18
K19
8532K1
K9
K4
K6
K8
8532K5
K2
K7
K10
K11
8532K3
K12
K13
K15
K16
K17
8530K91
K99
K94
K96
K98
8530K95
K92
K97
K910
K911
8530K93
K912
K913
8531K91
K99
K94
K96
K98
8531K95
K92
K97
K910
K911
8531K93
K912
K913
K914
K915
8531K916
K917
K918
K919
8532K91
K99
K94
K96
K98
8532K95
K92
K97
K910
K911
8532K93
K912
K913
K915
K916
K917
8530K31
K39
K34
K36
K38
8530K35
K32
K37
K310
K311
8530K33
K312
K313
8531K31
K39
K34
K36
K38
8531K35
K32
K37
K310
K311
8531K33
K312
K313
K314
K315
8531K316
K317
K318
K319
8532K31
K39
K34
K36
K38
8532K35
K32
K37
K310
K311
8532K33
K312
K313
K315
K316
K317
TWO POLE
OFF
NONE
NONE
OFF
OFF
*
NONE
OFF
OFF
NONE
NONE
OFF
ON
ON
ON
ON
ON
ON
ON
ON
8531
FOUR POLE
8532
OFF
NONE
NONE
OFF
OFF
*
NONE
OFF
OFF
NONE
NONE
OFF
ON
ON
ON
ON
ON
* Momentary contact.
See page A71 for circuit diagrams.
EATON CORPORATION Aerospace
TF300-5 June, 2004
A11
Why can't I download the program using the USB emulator on the MSP430F5438 minimum system I use?
What is going on? I have tried it in WinXP and it is the same. Please help!!! Below is a screenshot of the pop-up window when clicking the download button:...
流星123 Microcontroller MCU
“Typical Value” – What Does It Really Mean in a Data Sheet Specification?
Designers sometimes find op amp data sheet specifications confusing because not all performance characteristics have minimum or maximum specifications. Sometimes you have to use the "typical value" in...
maylove Analogue and Mixed Signal
Requesting TCP/IP software package for ZLG
Requesting TCP/IP software package for ZLG...
0212009623 Microcontroller MCU
I would like to ask about PCB proofing and welding
I would like to ask everyone in the forum whether you guys make both the sample PCB and the soldered components in the same company when you make PCB? I asked several manufacturers today and they usua...
905377346 stm32/stm8
Seven tips for embedded development
[i=s] This post was last posted by fish001 on 2019-2-11 22:41 Edit[/i] [size=4][color=#000000][backcolor=white] Being an embedded engineer is a laborious process that requires developers to maintain a...
fish001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 773  1893  2877  308  2583  16  39  58  7  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号