56.32.8.012.2090

Description
Electromechanical Relay, DPDT, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.32.8.012.2090 Overview

Electromechanical Relay, DPDT, AC/DC Output

56.32.8.012.2090 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width20.7 mm
body height37.2 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)9.6 V
Coil resistance50 Ω
Maximum coil voltage (AC)13.2 V
Nominal coil voltage12 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts4000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Cadmium Oxide
Number of terminals8
operating hours8 ms
physical size27.7mm x 20.7mm x 37.2mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay functionDPDT
release time3 ms
Terminal length0.007 inch
Termination typeQUICK CONNECT
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
MAX7219 Single-Chip and Two-Chip Cascade Drivers
MAX7219 Single-Chip and Two-Chip Cascade Drivers To explain:This word format was downloaded from Baidu. In the original version, the author only wrote a program to drive a MAX7219 . The first time I u...
编号洞洞拐 51mcu
Are there any colleagues from Harbin?
I am working in Harbin as a MCU engineer. I am at home and do not have a company. Is there anyone willing to cooperate with me?My phone number: 13766867932 QQ: 909987836...
tzl MCU
Please tell me about the electromagnetic field formula
I would like to ask what is the difference between 1 and 2 in the following formula, and how the three terms on the right side of the formula are derived? I don’t understand, so please explain it to m...
深圳小花 MCU
What instruments and equipment do I need to buy to apply wireless sensors?
My laboratory is a general department in the field of national defense. In the past, it rarely involved electronics. In order to expand the application direction, I am preparing to invest in some comm...
joshua Embedded System
The high-definition craze has set off. Only by getting rid of misunderstandings can the value of high-definition be realized
At present, the high-definition craze has been set off, and video surveillance has begun to take full high-definition as a new goal. People have always been pursuing clear images, so the current high-...
xyh_521 Industrial Control Electronics
GPS solution with integrated multimedia functions
[b]Overview of Satellite Positioning[/b] The basic principle of global satellite navigation is: satellites transmit navigation messages, which include ranging precision factor, Kepler parameters, orbi...
jek9528 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1744  787  1927  783  1900  36  16  39  40  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号