EEWORLDEEWORLDEEWORLD

Part Number

Search

3.6ADOSJ6.3

Description
Electric Fuse, 6.3A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size88KB,5 Pages
ManufacturerEaton
Download Datasheet Parametric Compare View All

3.6ADOSJ6.3 Overview

Electric Fuse, 6.3A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder,

3.6ADOSJ6.3 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time5 weeks 5 days
body height192 mm
Body length or diameter51 mm
Built-in featuresINDICATOR
Circuit protection typeELECTRIC FUSE
Joule integral nominal45 J
Installation featuresINLINE/HOLDER
physical size51mm x 192mm
Rated breaking capacity50000 A
Rated current6.3 A
Rated voltage (AC)3600 V
Rated voltage (DC)3600 V
GuidelineDIN 43625; IEC; VDE
surface mountNO
Terminal shapeEND CAP
Base Number Matches1
HIGH VOLTAGE DIN DISTRIBUTION
3.6 kV – 36 kV FUSES
DIN Dimension Fuses To Spec. DIN 43.625
This product group covers current limiting fuses with dimen-
sions to DIN 43.625 and performance in compliance with
IEC 282-1.
Advantages of Edison High Voltage Current -
Limiting Fuse
The low power dissipation of Edison fuses ensures low tem-
perature rise of switchgear in which they are incorporated.
The elements use the ‘M’ (metallurgical) effect, similar to
that used in low voltage fuses. This ensures that, with melt-
ing on long time overloads, excessive temperatures are not
reached and damage to switchgear components, such as
epoxy encapsulating enclosures, is thus prevented. Fuses
of Continental European manufacture which in general do
not employ this feature are not only hotter running by com-
parison but also usually need to employ a higher current rat-
ing of fuse for the same service; thus an Edison 40A fuse is
equivalent in terms of thermal performance to many
Continental European types of 63A rating.
Edison fuses exhibit considerable limitation of current and
I
2
t under short circuit conditions. The stress on circuit com-
ponents is thereby minimized and the reduction of energy
release at the fault reduces fire risks.
Switching (arc) voltages are appreciably less than permitted
values and fall with lower values of recovery voltage. The
use of, for example, 12 kV fuse on 6/7.2 kV systems is
therefore permissible.
Striker Characteristics
The spring operated striker pin has a travel and energy out-
put in compliance with the requirements of DIN 43625 and
IEC 282-1.
Travel is approx. 26mm
Energy Output is approx. 0.6 joule
Force/Travel Output Characteristics
60
50
40
FORCE (N)
30
20
10
0
0
5
10
15
TRAVEL (mm)
20
25
30
Current Ratings
These are in accordance with the R10 and, in some cases,
the R20 series of preferred numbers.
131

3.6ADOSJ6.3 Related Products

3.6ADOSJ6.3 17.5SFLSJ50 3.6ADOSJ25 3.6ADOSJ40 7.2WKMSJ250 7.2WKMSJ315 7.2WKMSJ355
Description Electric Fuse, 6.3A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder, Electric Fuse, 50A, 17500VAC, 17500VDC, 35500A (IR), Inline/holder, Electric Fuse, 25A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder, Electric Fuse, 40A, 3600VAC, 3600VDC, 50000A (IR), Inline/holder, Electric Fuse, 250A, 7200VAC, 7200VDC, 40000A (IR), Inline/holder, Electric Fuse, 315A, 7200VAC, 7200VDC, 40000A (IR), Inline/holder, Electric Fuse, 355A, 7200VAC, 7200VDC, 63000A (IR), Inline/holder,
Reach Compliance Code compliant compli compliant compliant compliant compliant compliant
ECCN code EAR99 EAR99 EAR99 EAR99 EAR99 EAR99 EAR99
Factory Lead Time 5 weeks 5 days 5 weeks 6 days 5 weeks 5 days 5 weeks 5 days 5 weeks 5 days 5 weeks 5 days 5 weeks 5 days
body height 192 mm 292 mm 192 mm 192 mm 442 mm 442 mm 442 mm
Body length or diameter 51 mm 76.2 mm 51 mm 51 mm 76 mm 76 mm 76 mm
Circuit protection type ELECTRIC FUSE ELECTRIC FUSE ELECTRIC FUSE ELECTRIC FUSE ELECTRIC FUSE ELECTRIC FUSE ELECTRIC FUSE
Joule integral nominal 45 J 8100 J 130 J 800 J 220000 J 450000 J 640000 J
Installation features INLINE/HOLDER INLINE/HOLDER INLINE/HOLDER INLINE/HOLDER INLINE/HOLDER INLINE/HOLDER INLINE/HOLDER
physical size 51mm x 192mm 76.2mm x 292mm 51mm x 192mm 51mm x 192mm 76mm x 442mm 76mm x 442mm 76mm x 442mm
Rated breaking capacity 50000 A 35500 A 50000 A 50000 A 40000 A 40000 A 63000 A
Rated current 6.3 A 50 A 25 A 40 A 250 A 315 A 355 A
Rated voltage (AC) 3600 V 17500 V 3600 V 3600 V 7200 V 7200 V 7200 V
Rated voltage (DC) 3600 V 17500 V 3600 V 3600 V 7200 V 7200 V 7200 V
Guideline DIN 43625; IEC; VDE DIN 43625; IEC; VDE DIN 43625; IEC; VDE DIN 43625; IEC; VDE DIN 43625; IEC; VDE DIN 43625; IEC; VDE DIN 43625; IEC; VDE
surface mount NO NO NO NO NO NO NO
Terminal shape END CAP END CAP END CAP END CAP END CAP END CAP END CAP
Maker Eaton - Eaton Eaton Eaton Eaton Eaton
Built-in features INDICATOR - INDICATOR INDICATOR INDICATOR INDICATOR INDICATOR
Base Number Matches 1 1 1 1 - - -
Is it Rohs certified? - incompatible - - incompatible incompatible incompatible

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 299  726  1248  1040  388  7  15  26  21  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号