EEWORLDEEWORLDEEWORLD

Part Number

Search

BR23AX-C1-V1

Description
Power/Signal Relay, 4 Form C, 4PDT, Latched, 0.4A (Coil), 6VDC (Coil), 2400mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount,
CategoryMechanical and electronic products    relay   
File Size156KB,2 Pages
ManufacturerMicrosemi
Websitehttps://www.microsemi.com
Download Datasheet Parametric View All

BR23AX-C1-V1 Overview

Power/Signal Relay, 4 Form C, 4PDT, Latched, 0.4A (Coil), 6VDC (Coil), 2400mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount,

BR23AX-C1-V1 Parametric

Parameter NameAttribute value
MakerMicrosemi
Reach Compliance Codecompliant
ECCN codeEAR99
body width25.4 mm
body height33.02 mm
Body length or diameter27.31 mm
Maximum coil current (DC)0.4 A
Coil operating voltage (DC)4.4 V
Coil power2400 mW
Coil release voltage (DC)3 V
Coil resistance15 Ω
Maximum coil voltage (DC)6 V
Nominal coil voltage6 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@115VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts1250 Vrms
Dielectric strength between breaking contacts1250 Vrms
Electrical life100000 Cycle(s)
Input switching control typeRandom
Insulation resistance10000000000 Ω
JESD-609 codee3
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
Number of terminals16
operating hours12 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB hole count16
physical size27.31mm x 25.4mm x 33.02mm
GuidelineMIL-PRF-39016
Relay actionLATCHED
Relay style4 FORM C
Relay function4PDT
Relay typePOWER/SIGNAL RELAY
release time12 ms
surface mountNO
Terminal surfaceTIN
Terminal length0.0053 inch
Termination typeSOLDER
weight84 g
Base Number Matches1
BR23
Crystal Can
Welded • 4PDT
Magnetic Latching
Dry Circuit to 10 Amps
PATENTED CONTACT STRUCTURE?
for the most reliable 10-amp magnetic latching relay in the industry
AVAILABLE WITH BIFILAR WOUND COIL?
for inductive spike suppression
SPACE ENVIRONMENT VERSIONS?
can be manufactured under extreme high-reliability controls
SPECIFICATIONS
GENERAL
Contact Arrangement
.......................... 4PDT (4 Form C)
Magnetic Latching
Weight.........................................................
3.0 oz approx.
Designed to meet the requirements of MIL-PRF-39016.
PERFORMANCE
Contact Rating
(Note 1)
Resistive .............10 Amps @ 28 VDC or 115V 400 Hz
(Case Ungrounded)
Inductive .......................................3.5 Amps @ 28 VDC
Life
...................................100,000 operations minimum
o
@ rated load, 125 C
Latch/Reset Power:
BR23AX.................................................500 mv approx.
BR23BX................................................250 mw approx.
Latch/Reset Time
.......................... 10 ms max, excluding
bounce time at nominal coil voltage
Contact Bounce Time.......................................
2 ms max
@ 10 Amps 28 VDC
Contact Voltage Drop:
Before Life.......................100 mv max @ rated current
6 or 28 VDC
After Life ..........................200 mv max @ rated current
6 or 28 VDC
ENVIRONMENTAL
o
o
Temperature Range
............................... -65 C to +125 C
Vibration
(Note 2)............................... 0.4" DA 10 - 38 Hz,
20 G's 38 - 2,000 Hz
Shock (Operating)
(Note 2) ........................ 50 G's 11 ms
ELECTRICAL CHARACTERISTICS
Duty Cycle........................................................Continuous
Insulation Resistance
o
10,000 megohms @ 500V 25 C
o
1,000 megohms @ 500V 125 C
Dielectric Strength:
Sea Level:
Between Coils (BR23AX) ....................... 500 VRMS
Contact to Case ................................... 1,250 VRMS
Contact to Coil ..................................... 1,250 VRMS
Coil to Case ......................................... 1,000 VRMS
Across Open Contacts ........................ 1,250 VRMS
70,000 Feet
All points.................................................. 500 VRMS
Notes:
1.
For case grounded loads and other ratings, consult the
factory.
For applications requiring other shock and vibration
levels, consult the factory.
6.
3.
4.
For other ratings consult the factory.
Relay contacts which have switched high level currents
are no longer suitable for switching low level loads.
5.
Contacts were placed in the position shown by placing
voltage with the polarity shown on the indicated coil
(reset). To switch contacts, a voltage of indicated
polarity must be applied to the other coil (Latch).
Contacts were placed in position shown by placing
voltage with the polarity indicated on the coil. To switch
contacts a voltage of the reverse polarity must be
applied to the coil.
2.
14930 E. Alondra Blvd., La Mirada, CA 90638-5752 (714) 994-6500 FAX (714) 994-3013
W:2000 Rev. 3

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1867  1415  222  2103  1520  38  29  5  43  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号