Class H/K5 and R Fuse Blocks
CategoryAnalog mixed-signal IC    The signal circuit   
File Size620KB,5 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Environmental Compliance
Download Datasheet Parametric View All

LR60030-2 Overview

Class H/K5 and R Fuse Blocks

LR60030-2 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerLittelfuse
package instruction,
Reach Compliance Codeunknown
Base Number Matches1
Class H/K5 and R Fuse Blocks
250 and 600 Volt
SPECIFICATIONS
Voltage Rating:
250 Volts; 600 Volts
Ampere Ratings:0
– 600 amperes
Approvals:
UL Listed (File No. E14721)
CSA Certified (File No. LR73091)
RECOMMENDED FUSES
Class H Blocks
250V
600V
NLN
RLN
NLS
RLS
Class R Blocks
250V
600V
FLNR
KLNR
LLNRK
TLN
FLSR/FLSR_ID
KLSR
LLSRK/LLSRK_ID
IDSR
Class H fuse blocks are for use with Class H/K5 fuses, which
have an interrupting rating of up to 50,000 amperes. When
higher interrupting ratings are required, use Class R fuses
(200,000 A.I.R.) and Class R fuse blocks. Class R fuse blocks
are dimensionally the same as Class H blocks, but incorporate
a rejection feature which allows only Class R fuses to be in-
serted.
FEATURES/BENEFITS
Class H and Class R fuse blocks feature a one-piece fuse clip
design for positive electrical contact and minimum heat rise.
Side barriers provide isolation between poles. Bases on most
blocks are of molded phenolic or thermoplastic, UL rated at
150° C.
Class H 250V
Amp No. of
Rating Poles
1
2
3
1
2
3
1
2
3
1
3
1
3
1
3
Catalog
Number
LH25030-1
LH25030-2
LH25030-3
LH25060-1
LH25060-2
LH25060-3
LH25100-1
LH25100-2
LH25100-3
LH25200-1
LH25200-3
LH25400-1
LH25400-3
LH25600-1
LH25600-3
Connector Type
(Add suffix shown)
Screw Pressure
Plate
Box
Lug
Class H 600V
Maximum
Wire Size
Amp No. of
Rating Poles
1
2
3
1
2
3
1
2
3
1
3
1
3
1
3
Catalog
Number
LH60030-1
LH60030-2
LH60030-3
LH60060-1
LH60060-2
LH60060-3
LH60100-1
LH60100-2
LH60100-3
LH60200-1
LH60200-3
LH60400-1
LH60400-3
LH60600-1
LH60600-3
Connector Type
(Add suffix shown)
Screw Pressure
Plate
Box
Lug
Maximum
Wire Size
30
60
S (R)
S (R)
S (R)
S (R)
S (R)
S (R)
P (R)
P (R)
P (R)
100
200
400
600
C (R)
S & P = #10 CU
C (R)
C = #6 CU-AL
C (R)
C (R)
S = #10 CU
C (R)
C = #2 CU-AL
C (R)
C
C
#2/0 CU-AL
C
C
250 MCM CU-AL
C
CR
CR (2) 350 MCM CU-AL
C
(2) 500 MCM CU-AL
C
30
S (R)
S (R)
S (R)
P (R)
P (R)
P (R)
60
100
200
400
600
C (R)
S & P = #10 CU
C (R)
C = #6 CU-AL
C (R)
C (R)
S = #10 CU
C (R)
C = #2 CU-AL
C (R)
C
C
#2/0 CU-AL
C
C
250 MCM CU-AL
C
CR
CR (2) 350 MCM CU-AL
C
(2) 500 MCM CU-AL
C
Note: Reinforcing springs standard on all Class H fuse
blocks 100 amperes and above.
Note: Reinforcing springs standard on all Class H fuse blocks
100 amperes and above.
Class R 250V
Amp No. of
Rating Poles
1
2
3
1
2
3
1
2
3
1
3
1
3
1
3
Catalog
Number
LR25030-1
LR25030-2
LR25030-3
LR25060-1
LR25060-2
LR25060-3
LR25100-1
LR25100-2
LR25100-3
LR25200-1
LR25200-3
LR25400-1
LR25400-3
LR25600-1
LR25600-3
Connector Type
(Add suffix shown)
Screw Pressure
Plate
Box
Lug
Class R 600V
Maximum
Wire Size
Amp No. of
Rating Poles
1
2
3
1
2
3
1
2
3
1
3
1
3
1
3
Catalog
Number
LR60030-1
LR60030-2
LR60030-3
LR60060-1
LR60060-2
LR60060-3
LR60100-1
LR60100-2
LR60100-3
LR60200-1
LR60200-3
LR60400-1
LR60400-3
LR60600-1
LR60600-3
Connector Type
(Add suffix shown)
Screw Pressure
Plate
Box
Lug
Maximum
Wire Size
30
SR
SR
SR
PR
PR
PR
60
100
200
400
600
CR
CR
CR
CR
CR
CR
C
C
C
C
C
CR
CR
C
C
S & P = #10 CU
C = #6 CU-AL
S = #10 CU
C = #2 CU-AL
#2/0 CU-AL
250 MCM CU-AL
(2) 350 MCM CU-AL
(2) 500 MCM CU-AL
30
SR
SR
SR
PR
PR
PR
60
100
200
400
600
CR
CR
CR
CR
CR
CR
C
C
C
C
C
CR
CR
C
C
S & P = #10 CU
C = #6 CU-AL
S = #10 CU
C = #2 CU-AL
#2/0 CU-AL
250 MCM CU-AL
(2) 350 MCM CU-AL
(2) 500 MCM CU-AL
Note: Reinforcing springs standard on all Class R fuse blocks.
Note: Reinforcing springs standard on all Class R fuse blocks.
110
MSP430Ware Study Notes UART ACLK 9600-8-N-1
[p=26, null, left][color=#000][font=Arial]1. Before initializing UART0, you need to initialize ACLK, SMCLK and MCLK. In the sample code, XT1 is used, ACLK is 32768, and SMCLK and MCLK are about 8MHZ. ...
qinkaiabc Microcontroller MCU
BQ4050 charging and discharging failure
...
谢123 Microcontroller MCU
May I ask which library is LM7805 in?
May I ask which library the LM7805 is in? Thank you very much:loveliness:...
sobeautiful_198 PCB Design
Sincerely apply for a trial of the $89 FPGA development board
I have always wanted to buy a development board, but as an ordinary student, I cannot afford it financially. Moreover, I have been learning VerilogHDL and some hardware-related knowledge since my soph...
似水如烟 FPGA/CPLD
Kai-Fu Lee: The biggest difference between domestic education and Western education
[b]Q:[/b]How to form a certain thinking mode and train rigorous thinking? I am now a freshman in high school. I find it difficult to form a certain thinking mode in my studies, especially when I encou...
soso Talking
In serial communication mode 0, the RXD pin level
Heroes,In serial port working mode 0, RXD is used as the data serial transmission pin, and TXD is used as the synchronous clock shift pulse pin.Now if SBUF=0X00 is sent, theoretically a clock pulse ca...
lnmisay 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 565  1130  1141  1939  1871  12  23  40  38  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号