EEWORLDEEWORLDEEWORLD

Part Number

Search

MICD-057-20.32-TTL-TBR-2

Description
Interconnection Device, LEAD FREE
CategoryThe connector    The connector   
File Size2MB,6 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance
Download Datasheet Parametric View All

MICD-057-20.32-TTL-TBR-2 Overview

Interconnection Device, LEAD FREE

MICD-057-20.32-TTL-TBR-2 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
package instructionLEAD FREE
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
REVISION G
VERTICAL
(MICD-038-XX.XX-STR-STR-1 SHOWN)
FIG. 1
MICD-XXX-XX.XX-XXX-XXX-X-X
No OF POSITIONS
-019, -038, -057, -076, -095
(PER ROW)
LENGTH
-XX.XX (INCHES)
(03.75[95.3] MIN)
(SEE NOTE 2)
(SEE NOTE 8)
END OPTION
-F: SCREW OPTION FIRST END ONLY
-S: SCREW OPTION SECOND END ONLY
-B: SCREW OPTION BOTH ENDS
-N: NO CAPS
(SEE FIG. 3, SHEET 5 FOR EDGE MOUNT
END OPTIONS)
(SEE FIG. 4, SHEET 5 FOR DOUBLE
VERTICAL END OPTIONS)
(SEE FIG. 5, SHEET 5 FOR NO CAPS OPTIONS)
(LEAVE BLANK FOR STANDARD CAPS
BOTH ENDS)
WIRING OPTION
-1: PIN 1 TO PIN 1
-2: PIN 1 TO PIN 2
-3: PIN 1 TO PIN N-1
-4: PIN 1 TO PIN N
(SEE TABLE 9, SHEET 6)
SECOND END
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 3)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
LENGTH: XX.XX + "L" REF (SEE TABLE 4)
SUB-MICD-X-XXX-XX
N (SEE TABLE 3)
C1
LENGTH: XX.XX
N-1
(SEE TABLE 3)
01%
N
(SEE TABLE 3)
N-1 (SEE TABLE 3)
FIRST END
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 2)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
DO NOT
SCALE FROM
THIS PRINT
"A" REF
(TYP)
"B" REF
(TYP)
'A'
SUB-MICD-X-XXX-XX
1
2
.570 14.49
REF (TYP)
.845 21.47
REF (TYP)
ICD-XX-01
2
HDRL-11
(SEE NOTE 5)
STS-01
(TIGHTEN TO 1.4 - 1.7 IN-LBS)
(4 PLCS)
SUB-TCF-3850-19-01-XX.XX
(SEE TABLE 1 FOR QTY)
1
FIRST END
SECOND END
ICD-XX-01
LENGTH
REF
.292 7.42 REF (TYP)
NOTES:
* "C" REF
C2
C3
G
ICD-XX-02
1.
C
REPRESENTS A CRITICAL DIMENSION.
2. SUB-TCF LENGTH IS EQUAL TO MICD LENGTH.
3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED.
4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V.
5. TOP SUB-TCF NOT SHOWN IN THIS VIEW FOR CLARITY; HDRL-11
TO BE CENTERED ON LOWER SUB-TCF AS SHOWN; HDRL-11 IS
TO CONTAIN PART NUMBER, SHOP NUMBER, & DATE CODE.
6. FOR SUB-ASSEMBLY AND FINISHED GOOD PACKAGING REQUIREMENTS,
REFERENCE PACKAGING STANDARD CO-HD-WI-3033-M.
7. PARTS TO BE PROCESSED PER SAMTEC ACCEPTABILITY REQUIREMENTS:
HDR-PI-01 "CABLE ASSEMBLY WORKMANSHIP STANDARDS".
8. CABLE LENGTHS LONGER THAN 40.00 INCHES ARE NOT SUPPORTED BY
S.I. TEST DATA.
ICD-XX-02
DETAIL 'A'
SCALE 2.5 : 1
Pb
THIS PRODUCT MANUFACTURED
WITH LEAD-FREE PROCESSING
* -DV END OPTIONS ONLY
TOLERANCES DO NOT APPLY
TO REFERENCE DIMENSIONS.
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
ANGLES
.XX: .01[.3]
2
.XXX: .005[.13]
.XXXX: .0020[.051]
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
DESCRIPTION:
DWG. NO.
DO NOT SCALE DRAWING
SHEET SCALE: 1.25:1
0.635 HIGH-SPEED COAX CABLE ASSEMBLY
MICD-XXX-XX.XX-XXX-XXX-X-X
12/11/03
SHEET
1
OF
6
F:\DWG\MISC\MKTG\MICD-XXX-XX.XX-XXX-XXX-X-X-MKT.SLDDRW
BY:
KEVIN B
New Year's Day big distribution
See it and share it...
allkity Embedded System
RS485 multi-machine communication
I am planning to do multi-node data collection, and then use a master node to collect the slave node data. I am using MSP430f149 microcontroller. Currently, the simple point-to-point problem has been ...
fuxudong Microcontroller MCU
Please advise on the use of P port settings.
If I set the 0th and 1st bits of P5 port as output and the rest as input:P5DIR = 0x3;if I send data to the output port of P5: 0XFFP5OUT = 0XFF;then the 0th and 1st bits of P5 port are output as 1, wil...
lydzyw Microcontroller MCU
Has anyone written a program to measure AC voltage using a 51 machine?
[i=s] This post was last edited by paulhyde on 2014-9-15 03:02 [/i] The program I wrote to convert AC into a steamed wave to measure voltage is killing me. The screen keeps jumping around... Please gi...
niyuan Electronics Design Contest
orcad training PPT 02
orcad training PPT 02...
安_然 Analog electronics
List of common safety requirements for switching power supplies
[i=s]This post was last edited by Mufan001 on 2020-6-1 13:21[/i]Safety standards applicable to power suppliesContact current requirementsLocation and requirements of safe distanceComparison of safety ...
木犯001号 Power technology

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2625  896  2239  1339  1621  53  19  46  27  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号