Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
50
X
21
X
105mm (W
X
H
X
D) /75g max (without chassis and cover)
Convection
LDA
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV]
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LDA-2
LDA10F
External view
LDA
Performance data
¡
STATIC CHARACTERISTICS (LDA10F-5 )
¡
RISE TIME & FALL TIME (LDA10F-5 )
¡
OVERCURRENT CHARACTERISTICS (LDA10F-5 )
¡
DERATING CURVE
LDA-3
AC-DC Power Supplies Open Frame/Enclosed type
Ordering information
LDA15F
R
LDA
1
2
15
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*2
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LDA15F-3
9
3V 3.0A
LDA15F-5
15
5V 3.0A
LDA15F-12
15.6
12V 1.3A
LDA15F-15
15
15V 1.0A
LDA15F-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
ACIN 200V
LDA15F-3
LDA15F-5
LDA15F-12
LDA15F-15
LDA15F-24
AC85 - 264 1
f
or DC110 - 370
0.37typ (Io=100%)
0.23typ (Io=100%)
47 - 440 or DC
70typ
74typ
76typ
76typ
78typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
50
X
21
X
125mm (W
X
H
X
D) /95g max (without chassis and cover)
Convection
LDA
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV]
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LDA-4
LDA15F
External view
LDA
Performance data
¡
STATIC CHARACTERISTICS (LDA15F-5 )
¡
RISE TIME & FALL TIME (LDA15F-5 )
¡
OVERCURRENT CHARACTERISTICS (LDA15F-5 )
¡
DERATING CURVE
LDA-5
AC-DC Power Supplies Open Frame/Enclosed type
Ordering information
LDA30F
R
LDA
1
2
30
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*2
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LDA30F-3
18
3V 6.0A
LDA30F-5
30
5V 6.0A
LDA30F-12
30
12V 2.5A
LDA30F-15
30
15V 2.0A
LDA30F-24
31.2
24V 1.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
ACIN 200V
LDA30F-3
LDA30F-5
LDA30F-12
LDA30F-15
LDA30F-24
AC85 - 264 1
f
or DC110 - 370
0.8typ (Io=100%)
0.4typ (Io=100%)
47 - 440 or DC
70typ
75typ
77typ
78typ
79typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00 - 5.25V
Works at 115 - 140% of rating
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
55
X
26
X
133mm (W
X
H
X
D) /200g max (without chassis and cover)
Convection
LDA
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV]
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
There are still 3 days until the 23rd Winter Olympic Games in Pyeongchang~[/size][/font][/color][/align][align=left][color=rgb(0, 0, 0)][font=微软雅黑, Arial, Helvetica, sans-serif][size=18px]When the wor...
[i=s]This post was last edited by paulhyde on 2014-9-15 03:14[/i] Altium latest library files [latest, use genuine download] [url=http://yunpan.cn/Q9V4mMuL8JSnu]http://yunpan.cn/Q9V4mMuL8JSnu[/url] Yo...
I want to ask why I can't see the running icon of Protel_DXP_2004 in "Start" or on the desktop after the installation is complete? I installed the .iso using a virtual CD-ROM drive and then installed ...
:):) Is it okay to give the LaunchPad board power supply 3.3V? Is it okay to give the board power supply 3.3V? Is it okay to give the board power supply 3.3V? Is it okay to give the board power supply...
A line scan lens is an industrial lens used with line scan cameras. Its imaging principle is to capture the image of the workpiece using a linear sensor and then perform digital signal processing t...[Details]
To understand why car engines need gearboxes, we must first understand the characteristics of different types of engines. An engine refers to a machine that can convert a form of energy into kineti...[Details]
1 Introduction
In the mid-1960s, American scientist Maas conducted extensive experimental research on the charging process of open-cell batteries and proposed an acceptable charging curve for ...[Details]
According to foreign media reports, secondary battery materials company POSCO Future M announced that it has successfully developed two experimental (prototype) positive electrode materials for the...[Details]
This paper proposes a temperature real-time transmission and display solution based on LED optical data transmission, with Jingwei Yager low-power FPGA HR (Yellow River) series as the main controll...[Details]
UPS stands for Uninterruptible Power Supply, which includes energy storage devices. It is mainly used to provide uninterruptible power supply for devices that require high power stability.
...[Details]
Learned the following information.
Customer product: industrial computer motherboard
Glue application area: CPU/BGA filling
Glue color requirements: black or t...[Details]
With the gradual popularization of new energy vehicles in recent years, more and more people have been able to access and purchase electric vehicles. The structure of electric vehicles is composed ...[Details]
The Radxa Cubie A7A is a single-board computer (SBC) powered by the Allwinner A733 octa-core Cortex-A76/A55 SoC, equipped with a 3 TOPS AI accelerator and up to 16GB of LPDDR5 memory.
Fo...[Details]
The power transmission system between a car's engine and drive wheels is called its drivetrain. It ensures the necessary traction and speed under various driving conditions, and coordinates these t...[Details]
This series of articles aims to help readers have a brief understanding of the Hongke KPA Automation system and to quickly get started with MoDK, including: an introduction to Hongke KPA Automation...[Details]
Since entering the electronic components industry, I've learned that electronic components come in different packaging types. Some people have argued that different types of components may look the...[Details]
In a previous article, we introduced
the origin of
AVTP
and the meaning of the various header fields when using it to transmit audio. This article will explain the meaning and constraints of...[Details]
Industrial equipment plays a significant role in improving industrial automation and accelerating production efficiency. Industrial HMIs (Human-Machine Interfaces) serve as a communication platform...[Details]
Which one has lower driving cost, electric vehicles or fuel vehicles? This is a topic of great concern to car users. Structurally, electric vehicles do not have mechanical transmission systems such...[Details]