5LPCV2475

Description
Solid State Relays - Industrial Mount Lin.Prop.Contr. 300 VAC/75A 0-5VDC
CategoryLED optoelectronic/LED    photoelectric   
File Size597KB,5 Pages
ManufacturerCrydom
Websitehttp://www.crydom.com/en/index.shtml
Environmental Compliance
Download Datasheet Parametric View All

5LPCV2475 Online Shopping

Suppliers Part Number Price MOQ In stock  
5LPCV2475 - - View Buy Now

5LPCV2475 Overview

Solid State Relays - Industrial Mount Lin.Prop.Contr. 300 VAC/75A 0-5VDC

5LPCV2475 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCrydom
package instructionROHS COMPLIANT, PLASTIC PACKAGE-7
Reach Compliance Codecompliant
Other featuresWITH ZERO CROSS OVER CIRCUIT
control voltage
input typeDC
Maximum insulation voltage2500 V
JESD-609 codee3
Number of components1
Maximum on-state current75 A
Maximum operating temperature80 °C
Minimum operating temperature-30 °C
Optoelectronic device typesTRIGGER OUTPUT SSR
Output circuit typeSCR
total height26.7 mm
total length56.1 mm
Terminal surfaceTin (Sn)
Base Number Matches1
DataSheet
LPCV Series
Linear proportional controller
Ratings from 15A to 110A @ 240 VAC
0-5 V DC, 0-10 V DC, or 4-20mA input
For use with resistive loads only
Control Relays
PRODUCT SELECTION
Description
0-5 VDC Control
0-10 VDC Control
4-20 mA Control
15 A
5LPCV2415
10LPCV2415
20LPCV2415
25 A
5LPCV2425
10LPCV2425
20LPCV2425
40 A
5LPCV2440
10LPCV2440
20LPCV2440
75 A
5LPCV2475
10LPCV2475
20LPCV2475
5LPCV24110
10LPCV24110
20LPCV24110
110 A
OUTPUT SPECIFICATIONS (voltage)
(1)
Description
Operating Voltage (60Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/ sec]
240 VAC
20-300
600
10
200
OUTPUT SPECIFICATIONS (current)
(1)
Description
Maximum Load Current [Arms]
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I² t for Fusing (8.3 msec) [A² sec]
Minimum Power Factor (with Maximum Load)
15 A
15
0.10
150
1.6
1.48
94
0.5
25 A
25
0.10
250
1.6
1.02
260
0.5
40 A
40
0.10
625
1.6
0.63
1620
0.5
75 A
75
0.15
1000
1.6
0.31
4150
0.5
110 A
110
0.20
1500
1.6
0.28
9340
0.5
INPUT SPECIFICATIONS
(1)
Description
Control Voltage Range
Control Range Limits (Min/Msx)
Turn-On Threshold
Nominal Input Impedance
Sync Voltage (terminal 6 and 7)
5LPCV
0-5 VDC
-0.5/10 VDC
0.25 VDC
12.7K Ohm
16-24 VAC
10LPCV
0-10 VDC
-1.0/20 VDC
0.5 VDC
25 K Ohm
16-24 VAC
20LPCV
4-20 mA
-0.5/25 mA
4.5 mA
460 Ohm
16-24 VAC
POWER SUPPLY SPECIFICATION
(4)
Description
Input Voltage 50/60Hz
Output Voltage 50/60Hz (Sync Voltage)
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Terminals
Screw Torque Requirement
Weight (typical)
PS120
120 VAC
20 VAC/100mA
-30 to 80°C
-40 to 125°C
6-32 Screws, .25" Fastons
6-32 Screws -10 in lbs.
8.6 oz. (245g)
PS240
240 VAC
20 VAC/100mA
-30 to 80°C
-40 to 125°C
Do not forget to visit us at:
www.crydom.com
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.
ATMEL SAMR21 key interrupt program
[color=#333333][font=Helvetica, Tahoma, Arial, sans-serif][size=14px]I have been using an ATMEL board recently, but after writing the program, the interrupt has not been generated. I would like to ask...
zjw19921104 Microchip MCU
[Smartwatch for environmental experts] Part 8: Code migration for personnel going down the mine
1. Introduction Originally, this article was going to write about activity status recognition, but there were some problems with the code for the personnel going down the mine, so I did a code migrati...
PowerWorld onsemi and Avnet IoT Innovation Design Competition
LPC1500 Experience + (5) Usercode Signature Generation
LPCXpresso1549 Trial Report——(5)UsercodeSignatureGeneration[/font][/align][align=left] [/align][align=left] [/align][table] [tr][td=121][align=center][align=left]Document Number[/align][/align][/td][t...
mars4zhu NXP MCU
Research and design of household inverter power supply system
1 Introduction   The Northwest region of my country has a vast territory and abundant solar and wind energy resources, with an average annual solar radiation intensity of 6000-8400MJ/m2, an average an...
wxf1357 Analogue and Mixed Signal
Pure dry goods: A brief discussion on the frequency response and stability of amplifiers composed of op amps
Original post by @gmchen, about amplifier stability, and some personal experience in actual production that affects amplifier stability after the circuit design is completed. [/size][size=3] [/size] [...
EEWORLD社区 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 306  1852  2055  954  453  7  38  42  20  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号