EEWORLDEEWORLDEEWORLD

Part Number

Search

44A45-03-2-04N

Description
Rotary Switches Rotary Switch, Standard, solder lug, 45°, 3 deck, 2 pole/deck, 4 positions/pole, non-shorting
CategoryMechanical and electronic products    switch   
File Size433KB,4 Pages
ManufacturerGrayhill
Websitehttp://www.grayhill.com
Environmental Compliance
Download Datasheet Parametric View All

44A45-03-2-04N Online Shopping

Suppliers Part Number Price MOQ In stock  
44A45-03-2-04N - - View Buy Now

44A45-03-2-04N Overview

Rotary Switches Rotary Switch, Standard, solder lug, 45°, 3 deck, 2 pole/deck, 4 positions/pole, non-shorting

44A45-03-2-04N Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time16 weeks
Actuator length0.437 inch
Actuator materialSTAINLESS STEEL
Actuator typeSINGLE SHAFT TYPE
body height43.61 mm
Body length or diameter29.51 mm
Casing type3/8-32
center contact materialSILVER
Contact (AC) maximum rated load I2A@115VAC
Contact (AC) maximum rated R load5A@115VAC
Maximum contact current (AC)5 A
Maximum contact current (DC)1 A
Contact (DC) maximum rated R load1A@28VDC
Contact functionON-ON
Contact resistance0.05 mΩ
contact timeBREAK-BEFORE-MAKE
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Dielectric withstand voltage1000VAC V
Electrical life6000 Cycle(s)
End contact materialSILVER
Graduation angle45 deg
Insulation resistance1000000000 Ω
insulator materialDIALLYL
JESD-609 codee4
Installation featuresPANEL MOUNT-THREADED
Number of positions4
Number of switching segments3
surface mountNO
Switch actionLATCHED
switch functionDP4T
Switch typeROTARY SWITCH
Terminal surfaceSilver (Ag)
Terminal materialBRASS
Termination typeSOLDER
Base Number Matches1
Special Function Rotary Switches
SERIES 08,09,42,44,50
Spring Return
FEATURES
• Hold-To-Test, Hold-To-Calibrate,
And Other Momentary Applications
• Choice of Configurations, Ratings,
Styles and Circuitry
• 10,000 Cycles of Operation
DESCRIPTION
A spring return rotary switch has 1 or more momentary positions. Maintaining contact at momentary
positions requires rotational force. Releasing the force allows the mechanism to return the contact
to a normal, or detent, position.
DIMENSIONS
Series 08 & 09
DIM. A + .046 (1,17)
–.020 (0,51)
DIM. B REF.
STUD PROJECTION
Series 50
Equivalent to Series 50 Standard Switches
.500 ± .015
(12,7 ± 0,38)
DIA.
.320 ± .015 (8,13 ± 0,38)
CIRCLE OF CENTERS
COMMON
36°
± 3°
For all other dimensions and
specifications, see Standard
Switch pages.
No. of
Decks
1
2
3
4
5
6
Dim
A
.960
1.228
1.496
1.764
2.032
2.550
(24,38)
(31,19)
(38,0)
(44,81)
(51,61)
(64,77)
Dim
B
.062
.062
.062
.062
.062
.312
(1,57)
(1,57)
(1,57)
(1,57)
(1,57)
(7,92)
Series 42 & 44
DIM. A + .046 (1,17)
–.020 (0,51)
Rotary Switches
No. of
Decks
1
2
3
Dim.
A
1.025 (26,04)
1.371 (34,82)
1.717 (43,61)
For all other dimensions and
specifications, see Standard
Switch pages.
For all other dimensions and
specifications, see Standard
Switch pages.
CONFIGURATIONS
This configuration indicates a counterclockwise
force is required to hold the switch at position
#1. “M” indicates a momentary position
counterclockwise of “D” and "D", detented ones.
Positions
1
2
3
M D
D
Releasing this force breaks contact with position
#1 and returns the switch to #2. Normal rotary
switch detent action occurs when the switch is
rotated between position #2 and #3.
All of the configurations (except
MDM)
list a
basic 2 position arrangement which is shown in
italics. Example:
MDDDDD
or DDDDDM. Several
positions can be added during the switch
construction at the factory; but, any configuration
must always contain the 2 basic positions.
SELECTING A SWITCH
1. Select a Configuration:
The total number of
positions always includes the 2 basic positions.
A (4) position switch of DDDDM configuration
would have 3 detent positions counterclockwise
of the momentary position.
2. Select Series, Angle of Throw, and Style:
See the Choices Chart. The basic switch
description, series, and throw are as follows:
1
/
2
",
1
/
4
Amp, multi-deck
08 = 36° 09 = 30°
1", 1 Amp, multi-deck
42 = 36° 44 = 30°
1
/
2
", 200 mA, single deck 50 = 36°
Electrical ratings are the same as those of the
conventional switches with the exception of life.
Life is limited to 10,000 cycles of operation
(25,000 cycles for Series 50) due to the spring
arrangement. Dimensions are the same as for
conventional types except for the shaft flat
orientation of the 3, 4, 5, and 6 pole, Series 09
and 44 in the DDDDDM configuration (see
chart).
3. Select Poles & Positions Per Pole:
If you
do not find the poles and positions per pole you
need in one series, try another or contact the
factory. If the behind panel length is a problem,
select a multi-pole type instead of a single deck.
OPTIONS
Watertight panel seal; Multi-pole switches that
exceed the limits noted in the Selector Chart;
Series 50
MD
or
DM
configurations in Military
styles; Series 08, 09, & 44 in MMMDM MM, and
in MMDD MM, and in MMMMMD.
Not available through Distributors
ORDERING INFORMATION
Create the part number using this example.
Stem number from chart
(4 or 5 digits)
Number of Decks
Number of Poles/Deck
093103-2-045
Type of Contacts:
S=Shorting
N=Non-Shorting
Number of Positions/Pole
Exception: Numbers beginning with 5 are
already complete part numbers.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Civil defense system in the Federal Republic of Yugoslavia
Command system. Leading body for civil defense work. According to the Federal Republic of Yugoslavia's Defense Law, the Federal Government shall organize and implement the civil defense work of the wh...
绿草 Industrial Control Electronics
【GD32E231 DIY Contest】4. Achieve 60-second timing
[i=s]This post was last edited by ddllxxrr on 2019-5-25 06:17[/i] Because, for this competition, I used the idea of experimenting first and then drawing by myself. This almost failed because I did not...
ddllxxrr GD32 MCU
Why is the actual voltage of the power supply higher than the rated voltage?
I have a few power supplies, the kind that are a black tube with a wire, one is marked 9V, the other is marked 10V, why are the output voltages all 13V and 14V? Take them apart and you will see that t...
jialaolian Power technology
How to achieve on-off control of DC 120V, 75A?
What can I use to realize the on-off control of DC 120V, 75A? Because the power-on time is not long, the relay has found a model, but there is no suitable switch. Can I use an air switch? Is there a s...
leosky568 Power technology
Arm Quick Start
Arm Quick Start...
wqj_john ARM Technology
【DIY Creative LED V2】V2 version
Maybe making PCB, purchasing components and soldering in the first version was too troublesome for many netizens, so I revised it and made the second version. It only needs LED lights, ESP32 developme...
dcexpert MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1183  1819  2294  2334  183  24  37  47  4  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号