APT Reserves the right to change, without notice, the specifications and information contained herein.
1.40
Z
JC
, THERMAL IMPEDANCE (°C/W)
θ
1.20
1.00
0.80
0.60
0.40
0.20
0
0.7
0.5
0.3
0.1
0.05
10
-5
10
-4
SINGLE PULSE
0.9
Note:
PDM
t1
t2
Duty Factor D =
1
/
t2
Peak TJ = PDM x Z
θJC
+ TC
t
10
-3
10
-2
10
-1
1.0
RECTANGULAR PULSE DURATION (seconds)
FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION
RC MODEL
Junction
temp (°C)
0.320
°C/W
0.00278 J/°C
3-2005
Power
(watts)
0.515
°C/W
0.0421 J/°C
053-4203 Rev B
0.375
°C/W
Case temperature (°C)
0.242 J/°C
FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL
TYPICAL PERFORMANCE CURVES
100
t
rr
, REVERSE RECOVERY TIME
(ns)
200
60A
150
APT2x31_30DQ60J
T = 125°C
J
V = 400V
R
I
F
, FORWARD CURRENT
(A)
80
T
J
= 175°C
60
100
30A
15A
40
T
J
= 125°C
20
T
J
= 25°C
T
J
= -55°C
0
50
0.5
1.0
1.5
2.0
2.5
3.0
V
F
, ANODE-TO-CATHODE VOLTAGE (V)
Figure 2. Forward Current vs. Forward Voltage
1400
Q
rr
, REVERSE RECOVERY CHARGE
(nC)
1200
1000
800
600
400
15A
200
0
T = 125°C
J
V = 400V
R
0
0 200 400 600 800 1000 1200 1400 1600
-di
F
/dt, CURRENT RATE OF CHANGE(A/µs)
Figure 3. Reverse Recovery Time vs. Current Rate of Change
I
RRM
, REVERSE RECOVERY CURRENT
(A)
35
30
25
20
15
10
5
0
T = 125°C
J
V = 400V
R
0
60A
60A
30A
30A
15A
0 200 400 600 800 1000 1200 1400 1600
-di
F
/dt, CURRENT RATE OF CHANGE (A/µs)
Figure 4. Reverse Recovery Charge vs. Current Rate of Change
1.2
K
f
, DYNAMIC PARAMETERS
(Normalized to 1000A/µs)
1.0
0.8
0.6
0.4
0 200 400 600 800 1000 1200 1400 1600
-di
F
/dt, CURRENT RATE OF CHANGE (A/µs)
Figure 5. Reverse Recovery Current vs. Current Rate of Change
50
45
40
Duty cycle = 0.5
T = 175°C
J
t
rr
I
RRM
Q
rr
35
I
F(AV)
(A)
30
25
20
t
rr
Q
rr
0.2
0.0
15
10
5
25
50
75
100
125
150
T
J
, JUNCTION TEMPERATURE (°C)
Figure 6. Dynamic Parameters vs. Junction Temperature
200
C
J
, JUNCTION CAPACITANCE
(pF)
0
75
100
125
150
175
Case Temperature (°C)
Figure 7. Maximum Average Forward Current vs. CaseTemperature
0
25
50
150
100
3-2005
50
10
100 200
V
R
, REVERSE VOLTAGE (V)
Figure 8. Junction Capacitance vs. Reverse Voltage
0
1
053-4203 Rev B
APT2x31_30DQ60J
Vr
+18V
0V
D.U.T.
30µH
trr/Qrr
Waveform
di
F
/dt Adjust
APT6017LLL
PEARSON 2878
CURRENT
TRANSFORMER
Figure 9. Diode Test Circuit
1
2
3
4
I
F
- Forward Conduction Current
di
F
/dt - Rate of Diode Current Change Through Zero Crossing.
I
RRM
- Maximum Reverse Recovery Current.
Zero
1
4
5
3
2
trr - Reverse
Recovery
Time, measured from zero crossing where diode
current goes from positive to negative, to the point at which the straight
line through I
RRM
and 0.25 I
RRM
passes through zero.
Qrr - Area Under the Curve Defined by I
RRM
and trr.
0.25 IRRM
5
Figure 10, Diode Reverse Recovery Waveform and Definitions
SOT-227 (ISOTOP
®
) Package Outline
31.5 (1.240)
31.7 (1.248)
7.8 (.307)
8.2 (.322)
W=4.1 (.161)
W=4.3 (.169)
H=4.8 (.187)
H=4.9 (.193)
(4 places)
11.8 (.463)
12.2 (.480)
8.9 (.350)
9.6 (.378)
Hex Nut M4 H100
(4 places)
r = 4.0 (.157)
(2 places)
4.0 (.157)
4.2 (.165)
(2 places)
25.2 (0.992)
0.75 (.030) 12.6 (.496) 25.4 (1.000)
0.85 (.033) 12.8 (.504)
3.3 (.129)
3.6 (.143)
1.95 (.077)
2.14 (.084)
3-2005
14.9 (.587)
15.1 (.594)
30.1 (1.185)
30.3 (1.193)
38.0 (1.496)
38.2 (1.504)
Anti-parallel
Anode 2
APT2x30DQ60J
APT2x31DQ60J
Parallel
Cathode 1 Cathode 1
Anode 1
053-4203 Rev B
Dimensions in Millimeters and (Inches)
Cathode 2
Anode 1
Cathode 2
Anode 2
ISOTOP
®
is a Registered Trademark of SGS Thomson. APT’s products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522