• Ceramic package and metal lid assures high precision and reliability.
• Seam sealing.
Pb
RoHS
Compliant
APPLICATIONS:
• Cellular telephones, Pagers.
• Communication and Test equipment.
• High Density applications.
• PCMCIA and wireless applications.
5.0 X 3.2 X 1.1mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
PARAMETERS
ABRACON P/N
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @ 25°C
Frequency Stability over the
Operating Temperature
(Ref to + 25°C)
Equivalent Series Resistance
Shunt Capacitance C0
Load Capacitance CL
Drive Level
Aging (First Year) @ 25°C ± 3°C
Insulation Resistance
TABLE 1- Standard ESR
Frequency (MHz)
8.000 - 9.999 (Fund.)
10.000 -11.999 (Fund.)
12.000 - 15.999 (Fund.)
ABM3B Series
8.0MHz - 50.0MHz (Fundamental
50.1MHz - 125MHz (3rd overtone)
Fundamental or 3rd overtone
- 10°C to + 60°C (see options)
- 40°C to + 85°C
± 50 ppm max. (see options)
± 50 ppm max. (see options)
See table 1
7 pF max.
18 pF (see options)
100 µW max., 10 µW typical
± 5ppm max.
500 M Ω min at 100Vdc ± 15 V
ESR(
Ω)
max
200
100
70
Frequency (MHz)
16.000 - 50.000 (Fund.)
50.001 - 80.000 (3rd OT)
80.001 - 125.000 (3rd OT)
ESR(
Ω
max
)
50
60
80
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
LLC
2 Faraday, Suite# B
|
Irvine
|
CA 92618
Revised: 08.25.15
Ph. 949.546.8000
|
Fax. 949.546.8001
Visit
www.abracon.com
for Terms and Conditions of Sale
CERAMIC SMD CRYSTAL
ABM3B
Pb
RoHS
Compliant
ABM3B
Height (mm)
Blank: 1.1mm max
1: 0.8mm max
Frequency in MHz
e.g. 8.000MHz
14.31818MHz
26.000MHz
125.000MHz
Load Capacitance
Please specify CL(6 to
32pF) in pF or S for Series
Please contact ABRACON for
values under 6pF
5.0 X 3.2 X 1.1mm
| | | | | | | | | | | | | | |
OPTIONS AND PART IDENTIFICATION: (Left blank if standard)
–
MHz -
-
-
-
-
-
Blank: Bulk
T: 1k pcs per reel
T2: 250 pcs per reel
Packaging
Custom ESR
STD
if
other than standard
R□
□:
Specify a value in
Ω
(e.g.: R40)
Operating Temp.
E: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J****: -40°C ~ +105°C
K****: -40°C ~ +125°C
L*: -55°C ~ +125°C
Freq. Tolerance
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
U**: ± 10 ppm
G***: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 100 ppm
(*) Option Z only
(**)Standard temp or
options E and B only
(***)Standard temp or
options E, B, C and N
only.
(****) Freq. stability
±50ppm and ±100ppm
only. Contact ABRACON
for tighter freq. stability.
OUTLINE DIMENSIONS:
Please see Table 2 below for height and chamfer information.
Chamfer on PIN 1
(Default)
Table 2
Height (mm)
Chamfer PIN #
ABM3B 1.1mm max
#1 (Default), #4 (See Note)
ABM3B1 0.8mm max
#1 (Default), #4 (See Note)
Chamfer on PIN 4
(See Note)
Note: Due to the availability of raw materials, this part may be manufactured with the
chamfer on pin 4. Be advised that this does not affect the electrical characteristics
of the crystal in any way.
Dimension : Inches (mm)
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
LLC
2 Faraday, Suite# B
|
Irvine
|
CA 92618
Revised: 08.25.15
Ph. 949.546.8000
|
Fax. 949.546.8001
Visit
www.abracon.com
for Terms and Conditions of Sale
CERAMIC SMD CRYSTAL
ABM3B
REFLOW PROFILE:
Pb
RoHS
Compliant
5.0 X 3.2 X 1.1mm
| | | | | | | | | | | | | | |
TAPE & REEL:
T=1000pcsTape and reel
T2=250pcsTape and reel
Dimension : mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
[size=4] The length of a parameter RAM is 32 bytes. First is the 32-bit optional parameter OPT. For the optional parameters, the event priority, data unit size, source address/destination address chan...
Altium Designer Summer 09 release heralds the advent of graphical editing for assembly variants and board level annotations. This feature allows you to make changes quickly and efficiently from a sche...
Infineon Development Board 618 Promotion: The hot-selling list is revealed, with great gifts!Infineon flagship store is having a passionate 618 promotion, just for you, the electronic engineer:follow ...
I am emulating MSP430F2132 on proteus, but it always displays 0. I don't know why. The manual is painful to read. Please help me. The program is as follows: #include "msp430f2132.h" [backcolor=rgb(255...
Does the system allocate an irp stack location for each driver layer? If one is skipped, does that mean the bottom one is not used? If each driver layer has a completion routine, can the corresponding...
Calibrators are widely used in university experiments. Among them, there are two experiments in nuclear physics experiments in modern physics experiments (GM counter and β absorption) that require ...[Details]
Although improper medical device product design is not always associated with medical device-related errors. Studies of users have shown that lack of adequate training accounts for 70% to 90% of suc...[Details]
Project Overview
The micro urine analyzer we designed can detect ten parameters of urine, including white blood cells, nitrite, urobilinogen, protein, pH value, occult blood, specific g...[Details]
In today's society, heart disease has seriously affected people's life safety. Many patients with sudden heart attacks are threatened because they cannot get timely treatment. Traditional ECG monito...[Details]
Radio Frequency Identification (RFID) technology is a contactless automatic identification technology that uses radio frequency signals to read and write relevant data from target objects to achiev...[Details]
For more than 10 years, analog-to-digital converters (ADCs) have been widely used in industrial process control, medical instruments, communication systems, radar and other products as a booster of in...[Details]
As FPGAs incorporate more and more capabilities, the need for effective debugging tools will become more critical. Careful planning for internal visibility will enable teams to adopt the right debuggi...[Details]
Currently, it is impossible to dynamically obtain patient information in medical monitoring. Once the patient's condition worsens, emergency treatment cannot be implemented in the first place, and the...[Details]
With the rapid development of digital technology, various digital display screens have emerged, including LED, LCD, DLP, etc. There are various control systems for various digital large screens, in...[Details]
Due to the needs of medical development, in many cases, general thermometers can no longer meet the requirements of fast and accurate temperature measurement, such as measuring human body temperature ...[Details]
System Introduction
EraSoC-1000 series chips are high-performance SoCs (System on Chips) based on the Loongson core. With their powerful CPU processing capabilities, 64-bit floating-point ...[Details]
Introduction
The home ECG and blood pressure monitoring system consists of a data acquisition and recording device and a host computer electronic medical record management system. Therefor...[Details]
A correct circuit design cannot be manufactured 100% correctly when it is taken to the factory for manufacturing. It will always be affected by various uncertainties, such as deviations in manufact...[Details]
1 Introduction
Intelligent software agents are software programs that can perform specific tasks for users, have a certain degree of intelligence, can autonomously perform some tasks, and ...[Details]
With the advent of the new economic era represented by the Internet, PCs have lost their former glory, and smart 3C products (Computer, Communication and Consumer) will set off a new wave. As one o...[Details]