EEWORLDEEWORLDEEWORLD

Part Number

Search

BK-S501-125MA

Description
Cartridge Fuses
CategoryCircuit protection   
File Size809KB,2 Pages
ManufacturerEaton
Download Datasheet Parametric View All

BK-S501-125MA Online Shopping

Suppliers Part Number Price MOQ In stock  
BK-S501-125MA - - View Buy Now

BK-S501-125MA Overview

Cartridge Fuses

BK-S501-125MA Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerEaton
Product CategoryCartridge Fuses
RoHSNo -; RoHS Version Available
ProductCeramic Fuse
Current Rating125 mA
Fuse TypeFast Blow
Fuse Size / Group5 mm x 20 mm
Voltage Rating AC250 VAC
Mounting StyleHolder / Clip
PackagingBulk
Body StyleCylindrical
Diameter5.2 mm
Indicator StyleWithout Indicator
Length20 mm
Termination StyleClip
Unit Weight0.038801 oz
Technical Data
2051
Effective
June
2017
Supersedes
March
2011
S501
5 mm x 20 mm Fast-acting ceramic tube fuses
Agency information
cURus: File E19180, Guide JDYX2, JDYX8
CSA Component Acceptance: File 53787
SEMKO Approval: File 413779
VDE Approval: File 40015517
IMQ Approval: File EB405
CCC Approval: File 2005010207155691
BSI Approval: File KM55676
Product features
Fast-acting high breaking capacity
Optional axial leads available
5 mm x 20 mm physical size
Ceramic tube with silver-plated (50 mA-400 mA) and
nickel-plated (500 mA-10 A) endcaps.
Designed to IEC 60127-2
Ordering
information
Specify packaging, product and option code
Ratings above 6.3 A have a 0.8 mm diameter lead
With TR2 packaging code, lead wire length is 19.05 mm
In
50mA-4A
5A-6.3A
8A-10A
Electrical Characteristics
1.5 In 2.1 In
2.75 In
4 In
min
max
min
max
min
max
60 min 30 min 10 ms 2 sec 3 ms 300 ms
60 min 30 min 10 ms 3 sec 3 ms 300 ms
30 min 30 min 40 ms 20 sec 10 ms
1s
10 In
max
20 ms
20 ms
30 ms
Product
Code
S501-50-R
S501-63-R
S501-80-R
S501-100-R
S501-125-R
S501-160-R
S501-200-R
S501-250-R
S501-315-R
S501-400-R
S501-500-R
S501-630-R
S501-800-R
S501-1-R
S501-1.25-R
S501-1.6-R
S501-2-R
S501-2.5-R
S501-3.15-R
S501-4-R
S501-5-R
S501-6.3-R
S501-8-R
S501-10-R
Voltage Interrupting Rating at
Rating Rated Voltage (50Hz)
Vac
Vac
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
Typical DC
Cold Resistance
(Ω)*
157.5
39.0
27.9
20.0
12.3
8.5
6.0
4.4
3.3
2.2
0.460
0.340
0.245
0.231
0.176
0.113
0.073
0.053
0.037
0.027
0.019
0.014
0.009
0.008
Specifications
Typical
Typical
Melting I
2
t Voltage
(amps)
Drop (mV)†
0.0017
9000
0.0005
3300
0.0011
2600
0.0018
2300
0.0037
1900
0.008
1600
0.02
1350
0.027
1300
0.01
1400
0.018
1200
0.038
1050
0.064
1200
0.097
490
0.146**
330
0.313**
297
0.748**
239
2.0
205
3.9
190
8.1
160
14
160
25
155
48
150
104
102
155
111
Agency Approvals
IMQ VDE BSI SEMKO cURus
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CCC
X
X
MITI/
JET
CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X‡
X‡
X‡
X‡
X‡
X
X
X
* DC Cold Resistance (measured at <10% of rated current)
** I
2
t of 1A, 1.25A & 1.6A is measured at 10I
n DC
† Typical Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current)
‡ CSA approvals on these ratings will not be marked on the fuse cap
Excellent foreign switching power supply design software!
Very good foreign switching power supply design software! Since I have it, my design work has become much easier!...
qxvop Power technology
GPS satellite positioning and SMS remote transmission system
GPS satellite positioning and SMS remote transmission system...
rain Automotive Electronics
Pocket gas alarm
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:57[/i]...
探路者 Mobile and portable
How to deal with USB ReadFile error?
When I write a USB application using VC, I find that sometimes error 1167 appears when using ReadFile. Has anyone encountered this situation? How to deal with it?...
powerding Embedded System
Help, power circuit analysis
A power supply circuit, please analyze the working principle and the role of C3, R3, C4, VT1, VR1, please help me.This content is originally created by EEWORLD forum user aacm . If you need to reprint...
aacm Power technology
Three-part description of serial port sending program
LIBRARY IEEE;USE IEEE.STD_LOGIC_1164.ALL;USE IEEE.STD_LOGIC_ARITH.ALL;USE IEEE.STD_LOGIC_UNSIGNED.ALL; --LIBRARY ALTERA;--USE ALTERA.MAXPLUS2.ALL; LIBRARY LPM;USE LPM.LPM_COMPONENTS.ALL; ENTITY Uart_T...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 453  2790  1102  904  2255  10  57  23  19  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号