EEWORLDEEWORLDEEWORLD

Part Number

Search

2037-40-CLF

Description
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE LIBRE DE PLOMO
CategoryCircuit protection   
File Size366KB,2 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet Parametric View All

2037-40-CLF Online Shopping

Suppliers Part Number Price MOQ In stock  
2037-40-CLF - - View Buy Now

2037-40-CLF Overview

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE LIBRE DE PLOMO

2037-40-CLF Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerBourns
Product CategoryGas Discharge Tubes - GDTs / Gas Plasma Arrestors
Peak Pulse Current10 kA
DC Sparkover400 V
Number of Electrodes2 Electrode
Termination StyleAxial
Failsafe Protection Y/NFailsafe Not Protected
Diameter5 mm
Length4.9 mm
Operating Temperature Range- 55 C to + 85 C
TechnologyGas Discharge Tubes
Type2 Electrode Miniature Gas Discharge Tube
Mounting StyleThrough Hole
Insulation Resistance10 GOhms
Unit Weight0.352740 oz
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
n
5 mm diameter, 4 mm long (2035 series)
n
5 mm diameter, 5 mm long (2037 series)
n
UL Recognized
n
High surge current rating
n
Stable breakdown throughout life
n
RoHS compliant* versions available
M
PL
IA
NT
Applications
n
Telecommunications
n
Industrial electronics
n
Commercial electronics
n
Consumer electronics
n
Automotive, aircraft, military electronics
Characteristics
LE
AD
F
RE
E
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±15 %
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±15 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
(1)
*R
oH
S
CO
2035/2037 Series - Miniature 2-Pole Gas Discharge Tube
2035-2037-09
2035/2037-15
2035/2037-20
Model No.
2035/2037-23
2035/2037-25
2035/2037-30
(±20 % for Model 2035/2037-09) @ 100 V/s
90 V
300 V
550 V
150 V
Ro VE LEA
HS RS D
C ION FRE
OM S E
PL AR
IA E
NT
*
200 V
425 V
575 V
230 V
450 V
600 V
2035/2037-42
250 V
475 V
625 V
2035/2037-47
300V
525 V
650 V
2035/2037-60
350 V
550 V
2035/2037-35
350 V
600 V
750 V
2035/2037-40
Model No.
420 V
675 V
850 V
400 V
650 V
800 V
470 V
750 V
950 V
600 V
950 V
1100 V
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance (IR) ..................100 V (50 V for Models 2035/2037-09) .................................. > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................1 A .......................................................................................... ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage
(2)
.....................135 V, (52 V for Models 2035/2037-09, .................................. < 150 ms
80 V for Models 2035/2037-15)
Impulse Discharge Current ................10000 A, 8/20 µs
(3)
................................................................. 1 operation min.
5000 A, 8/20 µs ...................................................................... > 10 operations
1000 A, 10/350 µs .................................................................. 1 operation
100 A, 10/1000 µs ................................................................. > 300 operations
100 A, 10/700 µs ................................................................... > 500 operations
Alternating Discharge Current ...........20 Arms, 11 cycles
(3)
.............................................................. 1 operation min.
5 Arms, 1 s ............................................................................. > 10 operations
Operating Temperature ...................................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: xxxV.
• Sparkover limits after life ±20 % (-25 %, +30 % for Models 2035/2037-09 and 2035/2037-60) , IR>10
8
Ω.
• Other DC sparkover ranges available on request.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
(2)
(3)
Network applied.
DC Sparkover may exceed ±20 % but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Ask about the problem of the discharge tube
I want to build a mathematical model, which uses a capacitor C3 to provide a holding current for a discharge tube, so as to ensure that the discharge tube is reliably broken down in the main circuit. ...
nieshen Power technology
[Repost] Working principle and working mode of boost converter
[align=left][font=微软雅黑]What is a boost converter?[/font][/align][align=left][font=微软雅黑]A boost converter is called a parallel switching converter. Unlike a buck converter, the boost inductor is at the...
皇华Ameya360 Energy Infrastructure?
Please help me, IIC program for MSP430G2553, waiting online
The single-step simulation can pass, but the F5 direct run will stop at while(!(IFG2 & UCB0TXIFG)); //Judge whether UCB0TXBUF is empty, check the flag IFG2 = 0x82, and after sending data, the UCB0TXIF...
xtsoaa03122 Microcontroller MCU
I would like to ask about the Xilinx development software ISE? ?
I installed the Xilinx development software ISE10.1, but the patch IP update can never be installed, causing the IP core to be unusable. How can I solve this problem? ? Thank you!!...
aaron.zhu Embedded System
Problems with external ADC of CC2530
After some experiments, I feel that the 14-bit ADC (13-bit in actual use) of CC2530 is not very accurate, and the program debugging is complicated and the operability is not good. So I want to connect...
Ishmael RF/Wirelessly
UltraEdit / UEStudio Powerful editor Almost all code can be compiled
It’s a good assistant for learning! ! ! ! !...
dahaidhl MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2398  422  1149  1690  2400  49  9  24  35  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号