EEWORLDEEWORLDEEWORLD

Part Number

Search

3120-F321-P7T1-W01F-20A

Description
Circuit Breakers An extremely versatile range of rocker switch/thermal circuit breakers
CategoryCircuit protection   
File Size2MB,16 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

3120-F321-P7T1-W01F-20A Online Shopping

Suppliers Part Number Price MOQ In stock  
3120-F321-P7T1-W01F-20A - - View Buy Now

3120-F321-P7T1-W01F-20A Overview

Circuit Breakers An extremely versatile range of rocker switch/thermal circuit breakers

3120-F321-P7T1-W01F-20A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A [E-T-A Circuit Breakers]
Product CategoryCircuit Breakers
RoHSDetails
ProductThermal Circuit Breakers
TypeThermal Overcurrent
Current Rating20 A
Voltage Rating AC240 VAC
Voltage Rating DC50 VDC
Number of Poles2 Pole
Actuator TypeRocker
Operating Temperature Range- 30 C to + 60 C
IlluminatedNot Illuminated
Height25 mm
Length54 mm
Termination StyleBlade
Voltage Rating50 VDC, 240 VAC
Width35 mm
Mounting StyleSnap In
Factory Pack Quantity1
Thermal Circuit Breaker 3120-F...
Description
The 3120 circuit breaker/switch combination is an ON/OFF switch
with integral overcurrent protection (S-type TO CBE to EN/IEC
60934). The trip element is a bimetal. Type 3120 is ideally suited for
overload protection of motors, pumps, transformers and cables.
The 3120 circuit breaker is also available as a switch-only version in
accordance with the IEC/EN 61058 (see data sheet switch 3120-F-..Q1).
Product characteristics:
l
rocker or push button actuation
l
single pole and double pole versions
l
reliable switching behaviour (positively trip-free)
l
convenient snap-in mounting
l
international approvals
Options and add-on modules:
illumination
l
water splash protection
l
auxiliary contacts
l
under voltage trip
l
remote trip
l
magnetic trip
l
push-in terminals
l
appliance inlet module
l
1
Technical data
For details please see Technical information
Rated voltage
Current rating range
AC 240 V, DC 50 V
0.1...20 A
(up to 30A upon request for single pole
units)
30,000
30,000
30,000
30,000
operations
operations
operations
operations
at
at
at
at
at
at
at
at
1
1
1
1
1
1
1
1
x
x
x
x
x
x
x
x
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
inductive
inductive
resistive
inductive
inductive
inductive
inductive
inductive
Typical applications
Medical and laboratory equipment, apparatus and machine
construction, professional tools, household and garden appliances,
offices machines, audio equipment, machine tools
Typical life 1-pole
0.1...20 A
0.1...4 A
4.5...16 A
DC 28 V:
0.1...20 A
Typical life 2-pole
AC 240 V:
AC 240 V:
DC 50 V:
Current ratings and internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
0.1...16 A 50,000 operations
17...20 A 30,000 operations
DC 50 V:
0.1...16 A 50,000 operations
17...20 A 50,000 operations
Ambient temperature
-30 … 60 °C
Insulation coordination
(IEC 60664)
Dielectric strength
Operating area
pole to pole (2-pole)
Insulation resistance
Interrupting capacity I
cn
2.5 kV /2 reinforced insulation at
operating area
test voltage AC 3,000 V
test voltage AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A
10 x I
N
2.5...20 A
1-pole 150 A
2-pole 250 A
Interrupting capacity (UL 1077)
I
N
1-pole, 2- pole
1-pole, 2- pole
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A, C, 1
1000 A, C, 1
Degree of protection
(IEC 60529)
Vibration
Current consumption of illumination
Operating voltage
DC 12 V
DC 24 V
DC 48 V
AC 115 V
AC 230 V
Current consumption
Y
5.2 mA
4.5 mA
4.5 mA
2.8 mA
2.2 mA
R
2 mA
2.2 mA
2 mA
1.1 mA
0.9 mA
G
1.4 mA
1.6 mA
1.6 mA
1 mA
0.9 mA
Shock
Corrosion
Humidity
Mass
operating area IP40
terminal area IP00
with water splash cover IP54 or IP66
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
test to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
test to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
test to IEC 60068-2-11, test Ka
240 hrs in 95 % RH
test to IEC 60068-2-78,
test Cab
approx. 33 g (2-pole)
approx. 27 g (1-pole)
approx. 42 g (2-pole with PT terminals)
1806
www.e-t-a.de
1
If you are concerned about the safety of lithium batteries and polymer batteries, please take a look
[i=s] This post was last edited by qwqwqw2088 on 2016-8-18 09:07 [/i] [font=宋体][color=black][backcolor=white] There is no need to say much about the contents of lithium-ion and lithium-polymer batteri...
qwqwqw2088 Analogue and Mixed Signal
Idle Xilinx FPGA development board
A lot of idle boards are for sale [url]http://shop117037878.taobao.com/[/url] You can go to the store to have a look [img]http://www.eeboard.com/bbs/data/attachment/forum/201604/11/023940x79fx97wx9tlc...
PENGSHIFANG Buy&Sell
uint16 and unsigned int issues
In modular programming, define a function void LedDisplay(uint16 pBuff[]) in the .c file.Then declare this function in the .h file extern void LedDisplay(uint16 pBuff[]);uint16 is defined in a header ...
wangdabo Programming Basics
Wince ocx control registration problem
I used EVC4.0 to build an Active X project without adding any code. On the wince5.0 simulator, I copied the regsvrce and .ocx files in the x86 directory to the /windows directory. I ran regsvrce xxx.o...
lyn689 Embedded System
How to use bootm to boot kernel under U-BOOT
Note: u-boot is marked with: http://www.hhcn.com/cgi-bin/topic.cgi?forum=3&topic=651&show=0 u-boot-1.1.3 generated by the patch provided by keety Recently, people have been asking me about the problem...
绿茶 Embedded System
Does anyone know how to use cc2530 infrared receiver?
Seeking ideas...
xiangtian134 Wireless Connectivity

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1917  2808  506  975  2881  39  57  11  20  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号