EEWORLDEEWORLDEEWORLD

Part Number

Search

4220-T110-K0M1-H121-A-03A-V

Description
Circuit Breakers
CategoryCircuit protection   
File Size2MB,4 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

4220-T110-K0M1-H121-A-03A-V Online Shopping

Suppliers Part Number Price MOQ In stock  
4220-T110-K0M1-H121-A-03A-V - - View Buy Now

4220-T110-K0M1-H121-A-03A-V Overview

Circuit Breakers

4220-T110-K0M1-H121-A-03A-V Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A [E-T-A Circuit Breakers]
Product CategoryCircuit Breakers
ProductThermal Magnetic Circuit Breakers
TypeThermomagnetic
Current Rating300 mA
Voltage Rating AC240 VAC
Voltage Rating DC60 VDC
Number of Poles1 Pole
Actuator TypeSwitch
Operating Temperature Range- 30 C to + 60 C
IlluminatedNot Illuminated
Height12.3 mm
Length89.3 mm
Termination StyleScrew
Voltage Rating60 VDC, 240 VAC
Width73.2 mm
Mounting StyleDIN Rail
Factory Pack Quantity1
Thermal-Magnetic Circuit Breaker 4220-T...
Description
Single, double and three pole thermal-magnetic circuit breakers with
high rupture capacity to UL 489 (5 kA), EN/IEC 60934 (6kA) and UL
1077 (5 kA). With toggle actuation, positively trip-free mechanism, a
choice of characteristic curves and a wide range of current ratings in
finely graded steps from 0.1 A through 32 A. Auxiliary contacts (make or
break contacts) are optionally available. Track-mountable design, width
only 12.5 mm. Ease of wiring by means of an integral busbar concept:
line entry busbar LINE+ and signal busbars/signal jumpers.
US patent number:
US 8,098,119 B2 (Modularity)
US patent number:
US 7,978,033 B2 (Release Mechanism)
US patent number:
US 7,834,290 B2 (Quenching Chamber)
Typical applications
Protection of power supplies, equipment and cables in centralised
control systems and in decentralised installations serving automation,
petro-chemical, power plant, steel industry and similar industrial
applications.
single pole
4220-T...
1
three pole
Technical data
For further details please see catalogue section: Technical Information
Voltage rating
Ordering Information
Type number
4220
thermal-magnetic high performance circuit breaker
Mounting
T1
track-mounting
Number of poles
1
single pole
2
double pole
3
three pole
Additional feature
0
without actuator guard
1
with actuator guard
Main terminals
K0
screw terminals 16 mm
2
/ 10 mm
2
Characteristic curve
F1
thermal-magnetic, extremely fast, DC
F2
thermal-magnetic, fast, AC/DC
M1
thermal-magnetic, medium delay, AC/DC
T1
thermal-magnetic, long delay, AC/DC
Auxiliary contacts
H0
without
H1
with auxiliary contacts in all poles
H2
with auxiliary contacts only in pole 1 (2-pole plus)
H3
with auxiliary contacts only in poles 1+3 (3-pole plus)
H4
with auxiliary contacts only in pole 2 (3-pole plus)
H5
with auxiliary contacts only in the last pole
H6
with auxiliary contacts only in poles 1+2 (3-pole plus)
Auxiliary contact function
0
without
2
make contact (N/O)
3
break contact (N/C)
A
pole 1 make contact, all other poles break
contacts (2-pole plus)
B
poles 1+2 make contacts, other poles break
contacts (3-pole plus)
C
pole 1 break contact, other poles make
contacts (2-pole plus)
Auxiliary contacts – terminal design
0
without
1
screw terminals 1 mm
2
Voltage rating
A
≤ AC 277 V or ≤ DC 60 V
Current rating range
0.1...32 A
Approval logo (optional)
V
UL 489 (1-pole)
4220 - T1 1 0 - K0 M1- H1 2 1 - A - 10 A -V
ordering example
Current rating range
Auxiliary circuit
Typical life
IEC 60934 AC 240/415 V
AC 240 V:
DC 60 V:
UL 489
AC 120 V:
UL 1077 AC 277/480 V
AC 277 V:
DC 60 V:
AC 240 V; 3 AC 415 V (50/60 Hz); DC 60 V
UL: AC 120 V; AC 277 V; 3 AC 415 V;
DC 60 V
0.1...32 A
DC 10 - 30 V, 10 - 500 mA, resistive
1,000
6,000
6,000
6,000
3,000
6,000
6,000
cycles
cycles
cycles
cycles
cycles
cycles
cycles
at
at
at
at
at
at
at
1
1
1
1
1
1
1
x
x
x
x
x
x
x
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
ind. load
inductive load
resistive load
inductive load
inductive load
inductive load
resistive load
Ambient temperature
Storage temperature
Insulation co-ordination
Dielectric strength
operating area
pole to pole
main circuit to
auxiliary circuit
open main circuit
open auxiliary circuit
Insulation resistance
Interrupting capacity
I
nc
PC1
IEC 60934
Interrupting capacity
UL 489
Interrupting capacity
UL 1077
Protection class
(IEC 60529)
Vibration (sinusoidal)
-30...+60 °C (-22...+140 °F, T60)
-40…+60 °C (-40…+140 °F)
IEC 60664 2.5 kV / 2
re-inforced insulation in the operating area
IEC 60934
test voltage AC 3,000 V
(reinforced insulation)
test voltage AC 1,500 V
test voltage AC 1,500 V
test voltage AC 1,500 V
test voltage AC 250 V
> 100 MΩ (DC 500 V)
AC 240 V, AC 240/415 V: 6,000 A
DC 60 V: 6,000 A
AC 120 V: 5,000 A
AC 277 V, AC 277/480 V: 5,000 A
DC 60 V: 5,000 A
operating area IP30
terminal area IP00
± 0.38 mm (10-57 Hz), 5 g (57-500 Hz)
test to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
test to IEC 60068-2-27, test Ea
96 hrs in 5 % salt mist,
test to IEC 60068-2-11,test Ka
240 hrs in 95 % RH,
to IEC 60068-2-78, test Cab
moulded material
on symmetrical rail to EN 50022-35x7.5
12.5 x 89.3 x 87.1 (per pole)
Shock
Corrosion
Humidity
Housing material
Mounting
Mounting dimension
(w x h x d)
1646
www.e-t-a.de
1
Application analysis of SPI, IIC, IIS, and UART
SPI The full name of SPI interface is "Serial Peripheral Interface", which means serial peripheral interface. It was first defined by Motorola on its MC68HCXX series processors. SPI interface is mainl...
陌路绝途 ARM Technology
I want to learn 430
Today, I was hanging out at my classmate's place and saw 430 by chance. I felt that its unique features could be used and developed in many fields. I am a student studying test and measurement. In my ...
405289282 Microcontroller MCU
What would you do if you encountered a bear in the wild?
In the morning, the managers started discussing in the WeChat group what to do if you encounter a bear in the wild? :puzzle: Some said to turn around and run, some said to release a smoke bomb and the...
eric_wang Talking
[Project source code] Set a password for the root of the Ubuntu system
This article and design code were written by FPGA enthusiast Xiao Meige. Without the author's permission, this article is only allowed to be copied and reproduced on online forums, and the original au...
小梅哥 FPGA/CPLD
Which is better, using C#.net or EVC to build and operate SQL SERVER C?
Which is better, C#.net or EVC to build and operate SQL SERVER C? Our teacher gave us an assignment, which is to build a database under CE and synchronize it with SQL SERVER database. But there are tw...
zgy8864 Embedded System
I would like to ask about the setting of ranging resolution in ultrasonic ranging and how to use a timer to send 40khz ultrasonic waves
I want to use 51 single-chip microcomputer to make a simple ultrasonic rangefinder recently, and I am troubled by the following two problems. I hope experts can give me some advice. 1. When calculatin...
zhouyifeng1413 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1617  1141  2530  2183  751  33  23  51  44  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号