2026-15-C3FLF

Description
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 150V 3 Pole
CategoryWireless rf/communication    Telecom circuit   
File Size327KB,5 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2026-15-C3FLF Online Shopping

Suppliers Part Number Price MOQ In stock  
2026-15-C3FLF - - View Buy Now

2026-15-C3FLF Overview

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 150V 3 Pole

2026-15-C3FLF Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instruction,
Reach Compliance Codecompliant
Factory Lead Time5 weeks
JESD-30 codeO-XXSS-P3
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Number of terminals3
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeROUND
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal surfaceTin (Sn)
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced TRIGARD
®
Approximately 8 mm diameter, 11 mm long
UL Recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Aircraft and military electronics
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
(1)
Model No.
2026-07
75 V
275 V
700 V
2026-09
90 V
275 V
600 V
2026-15
150 V
350 V
575 V
2026-20
200 V
425 V
625 V
2026-23
230 V
450 V
650 V
2026-25
250 V
475 V
700 V
2026-26
260 V
475 V
700 V
Model No.
2026-30
300 V
550 V
775 V
ribution.
2026-35
350 V
625 V
875 V
2026-40
400 V
675 V
925 V
2026-42
420 V
725 V
1000 V
2026-47
470 V
800 V
1100 V
2026-60
600 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/μs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
(2)
...............................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20
μs
(3)
.................................................. 1 operation minimum
20000 A, 8/20
μs
...................................................... > 10 operations
5000 A, 10/350
μs
................................................... 1 operation
1000 A, 10/1000
μs
................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
(3)
............................................. 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Moisture Sensitivity Level ............................................................................................................................... 1
............................................................................................................................... 6
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering
process that does not exceed 210 °C.
Notes:
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108
Ω
(-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
(2)
(3)
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
WARNING Cancer and Reproductive Harm
www.P65Warnings.ca.gov
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice. Users should verify actual device performance in their specific
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the
last page of this document, and at
www.bourns.com/docs/legal/disclaimer.pdf.
AD574 analog ground and digital ground issues
I have a question for everyone. Can AD574 work normally if the analog ground and digital ground are not connected together?...
xiaoxiao1 Test/Measurement
There is a sentence in the color screen datasheet that I don't understand
In the overview of a color screen, there is a sentence like this, I don't understand what it means, and I haven't found satisfactory information on the Internet...
qijiguo99 Embedded System
Hercules' GUI code generator HALCoGen
HALCoGEN provides a graphical user interface that allows the user to configure peripherals, interrupts, clocks, and other microprocessor parameters. After configuring the device, the user can generate...
anvy178 Microcontroller MCU
[GD32L233C-START Review] 2. Non-blocking way to light up, blink, blink, blink...
[i=s]This post was last edited by freeelectron on 2022-1-20 19:15[/i]1 Introduction: The official demo uses a blocking method to light up the lamp, which means waiting. During the waiting period, the ...
freeelectron GD32 MCU
Two new millimeter-wave radars debut with a detection distance of 200 meters
Hitachi and Mitsubishi Electric exhibited smaller automotive millimeter-wave radars, both using the 76GHz frequency band. The two companies plan to start supplying the radars exhibited in 2008. Hitach...
frozenviolet Automotive Electronics
Question: How to use Tornado's built-in TCL command to implement the current project dependencies
How to use the command dependencies project directly without using the tornado graphical tool? Thank you,...
sdx_none Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 853  1016  1568  50  747  18  21  32  1  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号