EEWORLDEEWORLDEEWORLD

Part Number

Search

2-1393239-1

Description
RT115024
CategoryMechanical and electronic products    relay   
File Size483KB,4 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

2-1393239-1 Online Shopping

Suppliers Part Number Price MOQ In stock  
2-1393239-1 - - View Buy Now

2-1393239-1 Overview

RT115024

2-1393239-1 Parametric

Parameter NameAttribute value
Brand NameSchrack
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
body width12.7 mm
body height15.7 mm
Body length or diameter29 mm
Maximum coil current (DC)0.017 A
Coil operating voltage (DC)16.8 V
Coil power400 mW
Coil release voltage (DC)2.4 V
Coil resistance1440 Ω
Maximum coil voltage (DC)24 V
Nominal coil voltage24 V
Coil/Input Power TypeDC
Contact (AC) maximum rated power R load3000VA@400VAC
Contact (AC) maximum rated R load12A@400VAC
Maximum contact current (AC)12 A
Maximum contact current (DC)12 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts1000 Vrms
End contact materialSilver Nickel
End contact platingGOLD
Input switching control typeRandom
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
Number of terminals5
operating hours8 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count5
method of packingBOX
physical size29mm x 12.7mm x 15.7mm
GuidelineBEAB; FIMKO; SEMKO; UL; VDE
Relay actionMOMENTARY
Relay style1 FORM C
Relay functionSPDT
Relay typePOWER/SIGNAL RELAY
release time6 ms
sealFLUX-TIGHT
surface mountNO
Terminal length0.0036 inch
Termination typeSOLDER
weight14 g
Base Number Matches1
General Purpose Relays
PCB Relays
Power PCB Relay RT1
n
n
n
n
n
n
SCHRACK
1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact
DC or AC coil
5kV/10mm coil-contact, reinforced insulation
Ambient temperature 85°C (DC coil)
WG version: product in accordance to IEC 60335-1
Reflow version: for THR (Through-Hole Reflow) soldering process
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
F0144-C
Zb
Contact Data
(continued)
Mechanical endurance
DC coil
AC coil
AC coil, reflow version
>30x10
6
operations
>10x10
6
operations
>5x10
6
operations
Approvals
VDE Cert. No. 40007571, cULus E214025, cCSAus 1142018;
CQC in preparation
Technical data of approved types on request
Contact arrangement
1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
12A
16A
Limiting continuous current
12A
16A, UL: 20A
Limiting making current
max. 4s, duty factor 10%
25A
30A
Breaking capacity max.
3000VA
4000VA
Contact material
AgNi 90/10, AgNi 90/10 gold plated
Frequency of operation, with/without load
DC coil
360/72000h
-1
AC coil
360/36000h
-1
Operate/release time max., DC coil
8/6ms
Bounce time max., DC coil, form A/form B
4/6ms
Electrical endurance
see electrical endurance graph
1)
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
RT314 DC-coil A (NO)
16A, 250VAC, cosφ=1, 85°C
30x10
3
RT314 DC-coil C (CO)
16A, 250VAC, cosφ=1, 85°C
10x10
3
RT314 DC-coil A (NO)
10A, 400VAC, cosφ=1, 85°C
150x10
3
RT114 DC-coil A (NO)
12A, 250VAC, cosφ=1, 85°C
50x10
3
RT114 AC-coil A (NO)
12A, 250VAC, cosφ=1, 70°C
100x10
3
UL 508
RT314
A/B (NO/NC) 20A, 250VAC, general purpose, 85°C 6x10
3
RT334
A (NO)
16A, 250VAC, gen. purpose, 85°C
50x10
3
RT314
A (NO)
1hp, 240VAC, 40°C
1x10
3
RT314
A (NO)
FLA/LRA, 4.5/13.1A, 480VAC, 70°C 100x10
3
EN60947-5-1
RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13
6.050
EN60730-1
RT314 DC-coil A (NO)
12(2)A, 250VAC, 85°C
100x10
3
1) For reflow solderable versions: actual contact performance may be influenced by the
reflow soldering process.
Contact Data
12A
16A
Coil Data
Coil voltage range, DC coil/ AC coil
Operative range, IEC 61810
Coil insulation system according UL
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.5
006
6
4.2
009
9
6.3
012
12
8.4
020
20
14.0
024
24
16.8
048
48
33.6
060
60
42.0
110
110
77.0
5 to 110VDC / 24 to 230VAC
2
class F
Release
voltage
VDC
0.5
0.6
0.9
1.2
2.0
2.4
4.8
6.0
11.0
Coil
resistance
Ω±10%
2)
62
90
200
360
952
1440
5520
8570
2)
28800
2)
Rated coil
power
mW
403
400
400
400
420
400
417
420
420
2) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Coil versions, AC coil 50/60 Hz
Coil
Rated
Operate
code
voltage
voltage
VAC
VAC
524
24
18.0
615
115
86.3
620
120
90.0
700
200
150.0
730
230
172.5
Release
voltage
VAC
3.6
17.3
18.0
30.0
34.5
Coil
resistance
Ω±15%
3)
350
3)
8100
8800
24350
32500
Rated coil
power
VA
0.76
0.76
0.75
0.76
0.74
3) Coil resistance ±10%.
All figures are given for coil without pre-energization, at ambient temperature +23°C, 50 Hz.
Other coil voltages on request.
10-2014, Rev. 1014
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
TMS320F28335P
Which great god has the package diagram of TMS3320F28335P already drawn?...
wd123 Automotive Electronics
Password theft is hard to prevent: Experts reveal three major online banking scams
Source: Beijing Modern Business Daily Time: 2006-7-10 07:39Recently, online banking users have been robbed of huge sums of money. Currently, more than 70 users in more than a dozen cities including Be...
gaoyanmei Talking
The digital tube display problem that has troubled me for a long time!
I use two traditional 573 digital tubes to control the display. The strange thing is that when it is displayed as a single bit, everything is normal. But when it comes to multi-bit scanning display, s...
huangyit MCU
Array antenna that can withstand -170℃ low temperature
JPL's all-metal design is designed to withstand Europa's harsh environment.Europa, one of Jupiter's Galilean moons, has at least twice as much liquid water as Earth's oceans. An ocean estimated to be ...
btty038 Robotics Development
Working Principle of Crystal Oscillator
[i=s]This post was last edited by paulhyde on 2014-9-15 09:11[/i]Keywords: Crystal Oscillator Quartz Crystal Quartz crystal oscillator is a high-precision and high-stability oscillator, which is widel...
dtcxn Electronics Design Contest
SD card TF card interface pin definition
...
Jacktang RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 993  1111  1077  1061  227  20  23  22  5  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号