Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
■
Sealing characteristics that meet IEC IP67 degree of protection.
■
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
■
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
■
Multiple mounting possible with Switches with Plungers.
■
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
■
VCTF cables with CE marking.
(Applicable only to standard models.)
Be sure to read
Safety Precautions
on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
Standard Models
Pre-wired Models
Weather-resistant Models
D4C-@@@
(1) (2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
D4C-@0@@-@@@@@@
(1)
(2)
(3)
(4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
COM
NC
NO
Connector
3
2
4
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1
D4C
Ordering Information
Switches
Switches with No Operation Indicator
Ratings
Cable
Cable
length
(m)
3
Pin plunger
5
3
Roller plunger
5
Crossroller
plunger
3
5
3
Roller lever
5
Roller lever,
high
-sensitivity
Sealed pin
plunger
3
5
3
5
3
5
3
5
3
Plastic rod
5
Center roller
lever
3
5
D4C-1350
D4C-1260
D4C-1360
D4C-1550
D4C-1460
D4C-1560
D4C-1750
D4C-1660
D4C-1760
D4C-4350
D4C-4260
D4C-4360
D4C-4550
D4C-4460
D4C-4560
D4C-1320
D4C-1224
D4C-1324
D4C-1231
D4C-1331
D4C-1232
D4C-1332
D4C-1233
D4C-1333
D4C-1250
D4C-1520
D4C-1424
D4C-1524
D4C-1431
D4C-1531
D4C-1432
D4C-1532
D4C-1433
D4C-1533
D4C-1450
D4C-1720
D4C-1624
D4C-1724
D4C-1631
D4C-1731
D4C-1632
D4C-1732
D4C-1633
D4C-1733
D4C-1650
D4C-4320
D4C-4224
D4C-4324
D4C-4231
D4C-4331
D4C-4232
D4C-4332
D4C-4233
D4C-4333
D4C-4250
D4C-4520
D4C-4424
D4C-4524
D4C-4431
D4C-4531
D4C-4432
D4C-4532
D4C-4433
D4C-4533
D4C-4450
D4C-1302
D4C-1203
D4C-1303
D4C-1220
D4C-1502
D4C-1403
D4C-1503
D4C-1420
D4C-1702
D4C-1603
D4C-1703
D4C-1620
D4C-4302
D4C-4203
D4C-4303
D4C-4220
D4C-4502
D4C-4403
D4C-4503
D4C-4420
D4C-1301
D4C-1202
D4C-1501
D4C-1402
D4C-1701
D4C-1602
D4C-4301
D4C-4202
D4C-4501
D4C-4402
Standard
5 A at 250 VAC, 4 A at 30 VDC
VCTF oil-resistant
cable
*1
VCTF cable
*2
SJT(O) cable
*3
Model
D4C-1201
D4C-1401
D4C-1601
D4C-4201
D4C-4401
Microload
0.1 A at 125 VAC, 0.1 A at 30 VDC
VCTF oil-resistant
cable
*1
VCTF cable
*2
Actuator
Sealed roller
plunger
Sealed
crossroller
plunger
Note: 1. Models are available separately with resistance to viscous oils (oil drain holes are also available), but only with Plunger Models. Add “-M” to the model number
(example: D4C-1202 would be D4C-1202-M).
2. Switches with variable roller levers are also available. Ask your nearest OMRON representative for details.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables;approved by EN and IEC.
*3. Switches with SJT(O) Cables (cables approved by UL and CSA) are approved by UL and CSA.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
2
D4C
Standard Switches with Operation Indicator (Red)
Ratings
Cable
Cable
length (m)
3
Pin plunger
5
3
Roller plunger
5
Crossroller
plunger
3
5
3
Roller lever
5
Roller lever,
high
-sensitivity
Sealed pin
plunger
3
5
3
5
3
5
3
5
3
Plastic rod
5
Center roller
lever
3
5
D4C-2350
D4C-2260
D4C-2360
D4C-2550
D4C-2460
D4C-2560
D4C-3350
D4C-3260
D4C-3360
D4C-3550
D4C-3460
D4C-3560
D4C-2320
D4C-2224
D4C-2324
D4C-2231
D4C-2331
D4C-2232
D4C-2332
D4C-2233
D4C-2333
D4C-2250
D4C-2520
D4C-2424
D4C-2524
D4C-2431
D4C-2531
D4C-2432
D4C-2532
D4C-2433
D4C-2533
D4C-2450
D4C-3320
D4C-3224
D4C-3324
D4C-3231
D4C-3331
D4C-3232
D4C-3332
D4C-3233
D4C-3333
D4C-3250
D4C-3520
D4C-3424
D4C-3524
D4C-3431
D4C-3531
D4C-3432
D4C-3532
D4C-3433
D4C-3533
D4C-3450
D4C-2302
D4C-2203
D4C-2303
D4C-2220
D4C-2502
D4C-2403
D4C-2503
D4C-2420
D4C-3302
D4C-3203
D4C-3303
D4C-3220
D4C-3502
D4C-3403
D4C-3503
D4C-3420
D4C-2301
D4C-2202
D4C-2501
D4C-2402
D4C-3301
D4C-3202
D4C-3501
D4C-3402
0.1 A at 125 VAC
VCTF oil-resistant
cable
*1
VCTF cable
*2
Model
D4C-2201
D4C-2401
D4C-3201
D4C-3401
VCTF oil-resistant
cable
*1
0.1 A at 30 VDC
VCTF cable
*2
Actuator
Sealed roller
plunger
Sealed
crossroller
plunger
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables.; approved by EN and IEC.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
3
D4C
Microload Switches with Operation Indicator
Ratings
Cable
Cable
length (m)
3
Pin plunger
5
3
Roller plunger
5
Crossroller
plunger
3
5
3
Roller lever
5
Roller lever,
high
-sensitivity
Sealed pin
plunger
Sealed roller
plunger
Sealed
crossroller
plunger
Plastic rod
5
D4C-5350
D4C-6350
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
* Oil-resistant vinyl cabtire cables; approved by EN and IEC.
3
5
3
5
3
5
3
5
3
D4C-5250
D4C-5232
D4C-5332
---
---
D4C-5320
D4C-5224
D4C-5324
---
---
D4C-6320
D4C-6224
D4C-6324
D4C-6231
D4C-6331
D4C-6232
D4C-6332
D4C-6233
D4C-6333
D4C-6250
D4C-5302
D4C-5203
D4C-5303
D4C-5220
D4C-6302
D4C-6203
D4C-6303
D4C-6220
D4C-5301
D4C-5202
D4C-6301
D4C-6202
0.1 A at 125 VAC
VCTF oil-resistant cable*
Model
D4C-5201
D4C-6201
0.1 A at 30 VDC
VCTF oil-resistant
cable*
Actuator
Pre-wired Models (Use VCTF Oil-resistant Cable)
Ratings
Actuator
Pin plunger
Operation
indicator
1 A at 125 VAC
Without operation indicator
D4C-1001-AK1EJ@
With operation indicator
D4C-2001-AK1EJ@
1 A at 30 VDC
Without operation indicator
D4C-1001-DK1EJ@
With operation indicator
D4C-3001-DK1EJ@
Roller plunger
D4C-1002-AK1EJ@
D4C-2002-AK1EJ@
D4C-1002-DK1EJ@
D4C-3002-DK1EJ@
Sealed plunger
D4C-1031-AK1EJ@
D4C-2031-AK1EJ@
D4C-1031-DK1EJ@
D4C-3031-DK1EJ@
Sealed roller plunger
D4C-1032-AK1EJ@
D4C-2032-AK1EJ@
D4C-1032-DK1EJ@
D4C-3032-DK1EJ@
Roller lever (high-
sensitivity model)
D4C-1024-AK1EJ@
D4C-2024-AK1EJ@
D4C-1024-DK1EJ@
D4C-3024-DK1EJ@
Note: 1. The
@
contains the length of the cable.
For example: 30 cm
→
4C-1001-AK1EJ03
2. M1J models are also available. Contact your OMRON sales representative for further information.
3. Of the above model numbers, some with special specifications are not registered.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
4
D4C
Weather-resistant Models
Operation
indicator
Without operating indication
Standard
Ratings
Actuator
Roller lever
5
Roller lever (high-
sensitivity model)
3
5
3
Adjustable roller lever
5
3
Adjustable rod lever
5
D4C-1329-P
---
D4C-2329-P
D4C-3329-P
Note: Silicon rubber is used to increase resistance to the environment. Silicon rubber, however, can generate silicon gas. (This can occur at room temperature, but the
amount of silicon gas generated increases at higher temperatures.) Silicon gas will react as a result of arc energy and form silicon oxide (SiO
2
). If silicon oxide
accumulates on the contacts, contact interference can occur and can interfere with the device. Before using a Switch, test it under actual application conditions
(including the environment and operating frequency) to confirm that no problems will occur in actual.
D4C-1327-P
D4C-1229-P
D4C-4327-P
D4C-4229-P
D4C-2327-P
---
D4C-3327-P
D4C-3229-P
D4C-1320-P
D4C-1224-P
D4C-1324-P
D4C-1227-P
---
D4C-4224-P
D4C-4324-P
D4C-4227-P
---
D4C-2224-P
D4C-2324-P
D4C-2227-P
---
D4C-3224-P
D4C-3324-P
D4C-3227-P
Cable length (m)
3
D4C-1220-P
D4C-4220-P
5 A at 250 VAC
4 A at 30 VDC
Microload
0.1 A at 125 VAC
0.1 A at 30 VDC
Model
D4C-2220-P
D4C-3220-P
5 A at 125 VAC
With operating indication
Standard
4 A at 30 VDC
Mounting Plates(Order Separately)
The WL model incorporated by equipment can be replaced with the D4C together with the Mounting Plate without changing the position
of the dog or cam.
List of Replaceable Models
WL model (Actuator)
WLD/WL01D
(Top plunger)
WLD2/WL01D2
(Toproller plunger)
WLCA2/WL01CA2
(Roller lever)
D4C model (Actuator)
D4C-@@01
(Plunger)
D4C-@@02
(Roller plunger)
D4C-@@20
(Roller lever)
Plate
D4C-P001
D4C-P002
D4C-P020
Example of Replacement
Note: The position of the dog remains unchanged.
Dog
Dog
Note: The WL01@ is for micro loads.
Mounting
Plate
Individual Parts
Head/Actuator
Actuator
Pin plunger
Roller plunger
Crossroller plunger
Roller lever
Environment-resistant roller lever
Roller lever
Variable roller lever
Variable rod lever
Sealed pin plunger
Sealed roller plunger
Sealed crossroller plunger
Plastic rod
Center roller lever
Head (with actuator)
D4C-0001
D4C-0002
D4C-0003
D4C-0020
D4C-0020-P
D4C-0024
D4C-0027
D4C-0029
D4C-0031
D4C-0032
D4C-0033
D4C-0050
D4C-0060
Actuator
---
---
---
WL-1A100
WL-1A100P1
WL-1A100
HL-1HPA320
HL-1HPA500
---
---
---
---
---
Note: 1. The model numbers for heads are of the form D4C-00@@, with the numbers in the squares indicating the type of actuator.
2. Actuators for plunger models, plastic rod models, and center roller lever models cannot be ordered individually. They must be ordered together with the head.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
I have been using IAR before. There is a global variable used to record whether the instrument is reset due to watchdog or power-on. It is required that this variable cannot be assigned a value when t...
In the first two sections, we discussed the most popular interfaces of T-BOX: PHY and CAN. In the following sections, I will introduce the power supply, which is mainly divided into Wide Vin BUCK, Low...
[b][url=http://www.amobbs.com/thread-979583-1-1.html]What tool can be used to read the binary content of the ARM chip? Note that it is not to restore the source file, but to read the binary file and b...
Open source hardware is very popular abroad, but not many people in China play with it, which directly leads to a serious lack of information on Chinese forums... But this can't stop the charm of Beag...
[size=16px]When compiling with EW8051, many of the following two warnings appeared, but I just can't find the reason. Please help me, what is the reason for this warning. Last line of file ends withou...
To enable real-time monitoring of home security and automatically dial a number for voice prompts or send text messages when an alarm occurs, a GPRS-based embedded telephone alarm system was design...[Details]
The most significant feature of IPS panels is that both electrodes are located on the same surface, unlike other LCD panels, which have electrodes arranged on top and bottom surfaces in a three-dim...[Details]
In mobile technology, sensors are the primary input for measured signals and form a component of a sensor system. They include sensitive and transducer elements connected to carriers and circuits. ...[Details]
Capable of providing precise and efficient thermal management for artificial intelligence computing power, intelligent sensing and autonomous driving systems
Shenzhen, ...[Details]
According to foreign media reports, secondary battery materials company POSCO Future M announced that it has successfully developed two experimental (prototype) positive electrode materials for the...[Details]
Recently, AstroBo Robot, a subsidiary of Chenxing Automation, launched a new mobile collaborative palletizing product. Leveraging an omnidirectional mobile chassis, an intelligent scheduling system...[Details]
This paper proposes a temperature real-time transmission and display solution based on LED optical data transmission, with Jingwei Yager low-power FPGA HR (Yellow River) series as the main controll...[Details]
Permanent magnets are essential components in a wide range of household and industrial devices. They are particularly crucial in the renewable energy sector, including electric vehicle motors. Curr...[Details]
With the continuous development of the industrial automation industry, we are seeing an increasing number of intelligent devices using flexible, efficient, and precise robotic arms to p...[Details]
Reflow soldering is one of the most commonly used methods in electronics manufacturing, allowing for the soldering of large numbers of components in a relatively short time. However, any experience...[Details]
Linear motor modules have become the "sweet spot" in various fields due to their advantages such as long stroke, fast speed, high precision, smooth operation and long life. Different models of line...[Details]
According to Nikkei, a survey found that global electric vehicle battery supply is expected to reach more than three times the required quantity due to
cooling
demand for electric vehicles,...[Details]
On August 20, Geely announced its focus on "One Cockpit". Through a unified AI OS architecture, a unified AI Agent, and a unified user ID, it will achieve an All-in-One AI cockpit, create the first...[Details]
Tiantai Robot's official Weibo account announced on the evening of August 20 that Tiantai Robot Co., Ltd., together with strategic partners including Shandong Future Robot Technology Co., Ltd., Sha...[Details]
Wearable technology is taking off, with applications evolving rapidly, from smartwatches to fitness trackers and even smart wigs! Bluetooth Smart is at the center of this revolution. This is the se...[Details]