EEWORLDEEWORLDEEWORLD

Part Number

Search

44A30-02-2-04S

Description
Rotary Switches Rotary Switch, Standard, solder lug, 30°, 2 deck, 2 pole/deck, 4 positions/pole, shorting
CategoryMechanical and electronic products    switch   
File Size433KB,4 Pages
ManufacturerGrayhill
Websitehttp://www.grayhill.com
Environmental Compliance
Download Datasheet Parametric View All

44A30-02-2-04S Online Shopping

Suppliers Part Number Price MOQ In stock  
44A30-02-2-04S - - View Buy Now

44A30-02-2-04S Overview

Rotary Switches Rotary Switch, Standard, solder lug, 30°, 2 deck, 2 pole/deck, 4 positions/pole, shorting

44A30-02-2-04S Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGrayhill
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time16 weeks
Actuator typeSINGLE SHAFT TYPE
body height34.82 mm
Body length or diameter29.51 mm
Contact (AC) maximum rated R load1A@115VAC
Maximum contact current (AC)1 A
Maximum contact current (DC)1 A
Contact (DC) maximum rated R load1A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Electrical life6000 Cycle(s)
Graduation angle30 deg
JESD-609 codee3
Installation featuresPANEL MOUNT
Number of positions4
Number of switching segments2
surface mountNO
Switch actionLATCHED
switch functionDP4T
Switch typeROTARY SWITCH
Terminal surfaceTin (Sn)
Termination typeSCREW
Special Function Rotary Switches
SERIES 08,09,42,44,50
Spring Return
FEATURES
• Hold-To-Test, Hold-To-Calibrate,
And Other Momentary Applications
• Choice of Configurations, Ratings,
Styles and Circuitry
• 10,000 Cycles of Operation
DESCRIPTION
A spring return rotary switch has 1 or more momentary positions. Maintaining contact at momentary
positions requires rotational force. Releasing the force allows the mechanism to return the contact
to a normal, or detent, position.
DIMENSIONS
Series 08 & 09
DIM. A + .046 (1,17)
–.020 (0,51)
DIM. B REF.
STUD PROJECTION
Series 50
Equivalent to Series 50 Standard Switches
.500 ± .015
(12,7 ± 0,38)
DIA.
.320 ± .015 (8,13 ± 0,38)
CIRCLE OF CENTERS
COMMON
36°
± 3°
For all other dimensions and
specifications, see Standard
Switch pages.
No. of
Decks
1
2
3
4
5
6
Dim
A
.960
1.228
1.496
1.764
2.032
2.550
(24,38)
(31,19)
(38,0)
(44,81)
(51,61)
(64,77)
Dim
B
.062
.062
.062
.062
.062
.312
(1,57)
(1,57)
(1,57)
(1,57)
(1,57)
(7,92)
Series 42 & 44
DIM. A + .046 (1,17)
–.020 (0,51)
Rotary Switches
No. of
Decks
1
2
3
Dim.
A
1.025 (26,04)
1.371 (34,82)
1.717 (43,61)
For all other dimensions and
specifications, see Standard
Switch pages.
For all other dimensions and
specifications, see Standard
Switch pages.
CONFIGURATIONS
This configuration indicates a counterclockwise
force is required to hold the switch at position
#1. “M” indicates a momentary position
counterclockwise of “D” and "D", detented ones.
Positions
1
2
3
M D
D
Releasing this force breaks contact with position
#1 and returns the switch to #2. Normal rotary
switch detent action occurs when the switch is
rotated between position #2 and #3.
All of the configurations (except
MDM)
list a
basic 2 position arrangement which is shown in
italics. Example:
MDDDDD
or DDDDDM. Several
positions can be added during the switch
construction at the factory; but, any configuration
must always contain the 2 basic positions.
SELECTING A SWITCH
1. Select a Configuration:
The total number of
positions always includes the 2 basic positions.
A (4) position switch of DDDDM configuration
would have 3 detent positions counterclockwise
of the momentary position.
2. Select Series, Angle of Throw, and Style:
See the Choices Chart. The basic switch
description, series, and throw are as follows:
1
/
2
",
1
/
4
Amp, multi-deck
08 = 36° 09 = 30°
1", 1 Amp, multi-deck
42 = 36° 44 = 30°
1
/
2
", 200 mA, single deck 50 = 36°
Electrical ratings are the same as those of the
conventional switches with the exception of life.
Life is limited to 10,000 cycles of operation
(25,000 cycles for Series 50) due to the spring
arrangement. Dimensions are the same as for
conventional types except for the shaft flat
orientation of the 3, 4, 5, and 6 pole, Series 09
and 44 in the DDDDDM configuration (see
chart).
3. Select Poles & Positions Per Pole:
If you
do not find the poles and positions per pole you
need in one series, try another or contact the
factory. If the behind panel length is a problem,
select a multi-pole type instead of a single deck.
OPTIONS
Watertight panel seal; Multi-pole switches that
exceed the limits noted in the Selector Chart;
Series 50
MD
or
DM
configurations in Military
styles; Series 08, 09, & 44 in MMMDM MM, and
in MMDD MM, and in MMMMMD.
Not available through Distributors
ORDERING INFORMATION
Create the part number using this example.
Stem number from chart
(4 or 5 digits)
Number of Decks
Number of Poles/Deck
093103-2-045
Type of Contacts:
S=Shorting
N=Non-Shorting
Number of Positions/Pole
Exception: Numbers beginning with 5 are
already complete part numbers.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
VCA820 voltage-controlled gain OPA cannot be tested, please help
[i=s]This post was last edited by dontium on 2015-1-23 13:08[/i] Hi everyone: I am trying a TI VCA820 voltage-controlled gain OPA recently. I want to make the AGC Loop on page 22 of the manual, but I ...
PSIR Analogue and Mixed Signal
Effect of current on optical properties of white light LED
At present, the measurement method of LED optical parameters is still under discussion at home and abroad. LED is an electroluminescent device. When electrons and holes undergo radiation recombination...
探路者 LED Zone
MSP430 key program (including circuit diagram and source code)
MSP430 key program (including circuit diagram and source code) #include void Init_Port(void) { //Set all pins of P1 port to input mode during initialization P1DIR = 0; //Set all pins of P1 port to gen...
gaon Power technology
Using TI power timing controller in 5G MIMO application
5G is the current market trend in the field of communication equipment. Massive MIMO refers to the multiple inputs and multiple outputs commonly used in 64T64R applications. More transmitter and recei...
qwqwqw2088 Analogue and Mixed Signal
Design of 8-bit RISC CPU in FPGA
Design of 8-bit RISC CPU in FPGA1 Introduction  With the rapid development of digital communication and industrial control, the functions of application-specific integrated circuits ( ASICs ) are requ...
雷北城 FPGA/CPLD
Please recommend a board for beginners
I would like to ask you guys, I am just learning about microcontrollers, and I want to buy a suitable board on Taobao, do you have any recommendations?...
zszs1018 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2830  965  2861  2478  2862  57  20  58  50  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号