EEWORLDEEWORLDEEWORLD

Part Number

Search

D4A-1107-VN

Description
Limit Switches LIMIT SWITCH
CategoryMechanical and electronic products    switch   
File Size2MB,17 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric View All

D4A-1107-VN Online Shopping

Suppliers Part Number Price MOQ In stock  
D4A-1107-VN - - View Buy Now

D4A-1107-VN Overview

Limit Switches LIMIT SWITCH

D4A-1107-VN Parametric

Parameter NameAttribute value
MakerOMRON
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke7.5 mm
Actuator typeSIDE PLUNGER
body width42 mm
body height75.5 mm
Body length or diameter44 mm
Contact (AC) maximum rated R load10A@480VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@14VDC
Maximum contact voltage (AC)480 V
Maximum contact voltage (DC)14 V
Electrical life1000000 Cycle(s)
Manufacturer's serial numberD4A
Installation featuresPANEL MOUNT
Maximum operating force19.61 N
Maximum operating temperature100 °C
Minimum operating temperature-20 °C
Maximum pre-travel2.4 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSCREW
General-purpose Limit Switch
D4A-@N
The Limit Switch with Better Seal,
Shock Resistance, and Strength
A double seal on the head, a complete gasket cover, and
other features ensure a better seal (meets UL NEMA 3, 4,
4X, 6P, 12, 13).
Wide standard operating temperature range:
−40°C
to +100°C (standard type).
Models with fluoro-rubber available for greater resistance
to chemicals.
Block mounting method also reduces downtime for
maintenance.
DPDT, double-break models available for complex
operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved model.)
Be sure to read
Safety Precautions
on page 14 to 15 and
Safety Precautions for All Limit Switches.
CSM_D4A-_N_DS_E_4_2
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
D4A-@@@@N (Set model number)
(1) (2) (3)
(1) Receptacle box
1
2
3
4
: 1/2-14 NPT conduit (SPDT, double-break)
: 1/2-14 NPT conduit (DPDT, double-break)
: G 1/2 conduit (SPDT, double-break)
: G 1/2 conduit (DPDT, double-break)
(3) Head
01
02
03
04
05
17
18
06
07-V
07-H
08
09
10
11
12
14
15
16
: Roller lever, standard
: Roller lever, high-sensitivity
: Roller lever, low torque
: Roller lever, high-sensitivity, low torque
: Roller lever, maintained
: Roller lever, sequential operation
: Roller lever, center neutral operation
: Side plunger, standard
: Side plunger, vertical roller
: Side plunger, horizontal roller
: Side plunger, adjustable
: Top plunger, standard
: Top plunger, roller
: Top plunger, adjustable
: Flexible rod, spring wire
: Flexible rod, plastic rod
: Flexible rod, cat whisker
: Flexible rod, coil spring
(2) Switch Box
1
3
E
5
7
9
L
P
: SPDT, double-break, without indicator
: SPDT, double-break, neon lamp
: SPDT, double-break, LED (24 VDC, leakage current: 1.3 mA)
: DPDT, double-break, simultaneous operation, without indicator
: DPDT, double-break, sequential operation, without indicator
*1
: DPDT, double-break, center neutral operation, without indicator
*2
: DPDT, double-break, simultaneous operation, neon lamp
: DPDT, double-break, simultaneous operation, LED
*1. Use the D4A-0017N Special Head.
*2. Use the D4A-0018N Special Head.
Note: Fluoro-rubber sealed type is also available.
1
How to select diode and inductor components when designing a power supply
[font=新宋体]Today, in our group (group number: [size=3][color=#ff00ff][b]309018200[/b][/color][/size], everyone is welcome to join~[/font]{:1_124:}{:1_124:}{:1_124:}[font=新宋体]) we had a very lively disc...
okhxyyo Power technology
Confused about mounting IDE hard disk in WinCE5.0?
Confused about WinCE5.0 mounting IDE hard disk? There is a project that wants to use IDE44pin interface to mount at least 64GB external storage. Now I have the following questions to discuss with you:...
dld2 Embedded System
SAMD21 Development Board Trial Experience - First Look at the SAMD21 Xplained Pro Evaluation Platform
[align=left]The Atmel SAMD21 Xplained Pro development board is a platform for evaluating the ATSAMD21J18A microcontroller. The ATSAMD21J18A is based on the ARM Cortex-M0+ core, with a maximum operatin...
zjbwxl MCU
Introduction to the problem of hard-flex PCB proofing
[align=left][color=rgb(25, 25, 25)][font="][size=14px]I believe that anyone who knows the production process of FPC[b]hard-flex board proofing[/b] knows that electroplating is an indispensable and mos...
方学放 PCB Design
I am a senior student
I have already learned about C51 MCU. I want to ask the teachers, if I want to engage in MCU development in the future, what knowledge do I need to learn that is not taught in universities? Thank you....
lfaitq Embedded System
A problem with 2407 generating symmetrical PWM````
Because I just learned DSP, I used 2407 to generate 6-channel 3-pair symmetrical PWM. When I started to explore, the program always had problems compiling. Today I finished the program, but found that...
hurdy Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1474  1392  2847  1129  145  30  29  58  23  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号