The assembly of 3M Ribbon Cable Sockets, Series 451 .05" x .05" sockets and 3M
™
Flat Ribbon
Cable .025" can be accomplished when using the 3M Locator Plates, Series 3443-82-XX and the
3M
™
Assembly Press, Models 3640 or 3335.
3436-1K Shut Height Setting
Press
3640/3316
7
7
7
7
7
7
7
7
7
Press 3335
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
Connector
Part Number
45104
45106
45108
45110
45112
45114
45116
45120
45130
Locator
Plate Number
3443-82-04
3443-82-06
3443-82-08
3443-82-10
3443-82-12
3443-82-14
3443-82-16
3443-82-20
3443-82-30
Platen
Part Number
3442-9
3442-9
3442-9
3442-9
3442-9
3442-9
3442-9
3442-9
3442-9
November 2013
78-9101-8937-8
3
2.0
2.1
Procedures for Set-up
Adjust the shut height settings. (See Figures 2-4)
Cable Stop Holes
Cable Location Area
Assembly
Press Base
Mounting Holes
(4 Places)
Figure 1: 3M
™
Locator Plate 3443-82-20
3.0
Procedures for Adjusting Shut Height
3.3
The shut height should be adjusted from the base
before the locator plate is put into place.
The 3M
™
Assembly Presses 3316 and 3640 are
adjusted with a knob at the top of the press. The
3M
™
Assembly Press 3335 is adjusted with the collar
on the press shaft, and the 3M
™
Assembly Press 3830
are self-adjusting.
3.1
3.2
Place the shut height gauge across the
press base.
The shut height adjustment is made from the
base of the assembly press without the locator
plate or platen in place.
Lower the handle of the press until the handle
casting makes contact with the
press casting. (See Figure 2)
Figure 3
3.4
Rotate the shut height to lower or raise
adjustment feature until the bottom of the
shaft contacts the desired position on the shut
height gauge. (See Figures 3 and 4)
Figure 2
Figure 4
2
3.5
Install the 3M
™
Locator Plate and the
appropriate platen on the press. The platen
should be positioned parallel with the
connector body and cover.
(see Figure 5)
5.0
5.1
Procedures for Cable Termination
Place the socket connector onto the cover over
the cable, verifying the pin 1 indicator
is in the correct position. (see Figure 8)
After the cable is prepared it is ready for termination.
Figure 5
Figure 8
4.0
4.1
Procedures for Cable Preparation
Place the cover into the locator plate.
(See Figure 6)
Before assembly of the connector can take place, the
cable must be prepared.
5.2
Bring the handle of the press down until the
IDCs press into cable and the connector fully
seats into the cover. (see Figure 9)
Figure 9
5.3
Figure 6
Visually inspect termination to ensure
that:
4.2
Place the properly sized ribbon cable onto the
cover in the locator plate. (See Figure 7)
a. Cover is fully seated and parallel to
the body.
b. Cable is properly aligned with the cover.
c. Cover retaining devices on the body
are flush with the cover end.
(See Figure 10)
Figure 7
a. 0.0625 dowel pins can be used in the
cable stop location holes if so desired.
(Cable stop location holes not available
on sizes 4, 6, 8 and 10.)
Figure 10
3
6.0
6.1
Strain Relief Attachment
Fold the cable back over the cover.
(See Figure 11)
6.3
Press the strain relief down until the strain
relief snaps into the correct position on the
connector. (See Figure 13)
Figure 11
Figure 13
6.2
Place the strain relief in the connector over the
cable, sliding the strain relief into the slots of
the connector. (See Figure 12)
Figure 12
Customer and Technical Service
Within the U.S.:
Customer Service: 800-225-5373
3M is a trademark of 3M Company.
Outside of the U.S.:
For customer service, please contact your local 3M Electronic
Solutions Division representative.
Important Notice
All statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the
accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended
application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M’s current
publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by
an authorized officer of 3M.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase.
3M MAKES NO OTHER
WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product
or refund the purchase price of the 3M product.
Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or
consequential loss or damage arising from this 3M product, regardless of the legal theory asserted.
[align=left][color=#333333][backcolor=rgb(255, 255, 255)][font="][size=14px][url=https://www.eeworld.com.cn/huodong/TE_ZT_20170830/index.html]Learn about TE CONNECTIVITY outdoor lighting connection so...
Recently I need to use an SDRAM that complies with the Avalon interface protocol, but I find that the SDRAM controller generated using SOPC does not have the relevant signals for burst transmission. A...
Abstract: This paper introduces a method of using the powerful mathematical functions of the tool software MATLAB to enhance the simulation function of ALTERA's programmable logic device design softwa...
In the dual-machine parallel communication, 1K bytes of data are transmitted in parallel between two microcomputers A and B. Machine A sends and machine B receives. The 8255A on the A side works in mo...
Thanks to EEW for the new book I exchanged for~~ The administrator MM handled it very quickly~~~:kiss: One is "Easy Introduction and Practice of CAN Bus" by the blog Sutra Pavilion, which is a good re...
The core of a machine vision system is image acquisition and processing. All information comes from images, and image quality is crucial to the entire vision system. A good image can improve the st...[Details]
As the number of cars increases, environmental pressures are also increasing. At this time, some people are saying that new energy vehicles are energy-efficient and environmentally friendly, and ar...[Details]
White light LEDs are voltage-sensitive devices. In actual operation, their upper limit is 20mA. However, the current often increases due to various reasons during use. If no protective measures are...[Details]
1 Introduction
In the mid-1960s, American scientist Maas conducted extensive experimental research on the charging process of open-cell batteries and proposed an acceptable charging curve for ...[Details]
Common Mode Semiconductor has officially released its latest generation of power management ICs—the GM6506 series. This fully integrated high-frequency synchronous rectification step-down p...[Details]
The Automotive Testing and Quality Assurance Expo (ATE 2025) will open on August 27th. At the expo, Rohde & Schwarz (R&S) will showcase six automotive testing solutions, themed "Intelligently Drivi...[Details]
With the rapid development of electric vehicles in my country, people are beginning to pay attention to the issue of radiation from electric vehicles. We all know that mobile phones emit radiation,...[Details]
Permanent magnets are essential components in a wide range of household and industrial devices. They are particularly crucial in the renewable energy sector, including electric vehicle motors. Curr...[Details]
introduction
In today's busy society, people experience chronic high stress, which in turn poses a significant threat to our health. Therefore, effectively relieving stress has become a pr...[Details]
Driven by business opportunities such as access to new markets and government initiatives like the Belt and Road Initiative, global expansion has become a significant trend for Chinese companies. C...[Details]
Today, the voltage of electronic products continues to rise to 400V, 600V and even 1000V, so there are few electronic load models that can handle such high voltages. Many people consider connecting...[Details]
With rapid economic development, the types of pollution sources are increasing, especially in chemical and industrial zones and their surroundings. The patterns of pollution and the types of ecolog...[Details]
EVTank predicts that all-solid-state batteries will achieve small-scale mass production in 2027 and large-scale shipments by 2030. Global solid-state battery shipments will reach 614.1GWh, of which...[Details]
Amid the increasing complexity of electronic system power management,
power architecture design
is undergoing a paradigm shift from experience-driven to tool-enabled.
Analog
Devices...[Details]
Industrial equipment plays a significant role in improving industrial automation and accelerating production efficiency. Industrial HMIs (Human-Machine Interfaces) serve as a communication platform...[Details]