EEWORLDEEWORLDEEWORLD

Part Number

Search

88970011

Description
Controllers M3 NB20R 8 4 24VDC
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size146KB,5 Pages
ManufacturerCrouzet
Download Datasheet Parametric View All

88970011 Online Shopping

Suppliers Part Number Price MOQ In stock  
88970011 - - View Buy Now

88970011 Overview

Controllers M3 NB20R 8 4 24VDC

88970011 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCrouzet
Product CategoryControllers
RoHSDetails
Analog / DigitalDigital
Display TypeNone
Operating Supply Voltage24 VDC
MountingDIN Rail
Size124.6 mm x 100 mm x 45.5 mm
Number of Outputs8
Output TypeRelay
Number of Inputs12
Factory Pack Quantity1
02/11/2015
www.crouzet.com
Bare board version NB20 Part number 88970011
Easy and discreet integration into your applications
Mass-production applications
Memory : up to 350 "typical" blocks in FBD language and 120 lines in LADDER language
Compact dimensions
Range of controllers for use with application specific functions
Part numbers
Type
88970011
NB20
Inputs
12 digital (of which 6 are analogue)
Outputs
8 relays
Supply
24 V DC
Specifications
General environment characteristics for CB, CD, XD, XB, XR and XE product types
Certifications
Conformity to standards (with the low voltage directive
and EMC directive)
CE, UL, CSA, GL
IEC/EN 61131-2 (Open equipment)
IEC/EN 61131-2 (Zone B)
IEC/EN 61000-6-2,
IEC/EN 61000-6-3 (*)
IEC/EN 61000-6-4
(*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Not included
In accordance with IEC/EN 60529 :
IP40 on front panel
IP20 on terminal block
3 in accordance with IEC/EN 60664-1
Degree : 2 in accordance with IEC/EN 61131-2
Operation : 2000 m
Transport : 3048 m
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Immunity to ESD
IEC/EN 61000-4-2, level 3
Immunity to radiated electrostatic fields
IEC/EN 61000-4-3
Immunity to fast transients (burst immunity)
IEC/EN 61000-4-4, level 3
Immunity to shock waves
IEC/EN 61000-4-5
Radio frequency in common mode
IEC/EN 61000-4-6, level 3
Voltage dips and breaks (AC)
IEC/EN 61000-4-11
Immunity to damped oscillatory waves
IEC/EN 61000-4-12
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1
(*) Except configuration (88 970 1.1 or 88 970 1.2) +
(88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
-20 →+70 °C 
except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure)
in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
-40 →+80 °C in accordance with IEC/EN 60068-2-1 and
IEC/EN 60068-2-2
95 % max. (no condensation or dripping water) in accordance with
IEC/EN 60068-2-30
On symmetrical DIN rail, 35 x 7.5 mm and 35 x 15 mm, or on panel (2 x Ø 4 mm)
Flexible wire with ferrule =
1 conductor : 0.25 to 2.5 mm
2
(AWG 24...AWG 14)
2 conductors 0.25 to 0.75 mm
2
(AWG 24...AWG 18)
Semi-rigid wire =
1 conductor : 0.2 to 2.5 mm
2
(AWG 25...AWG 14)
Rigid wire =
1 conductor : 0.2 to 2.5 mm
2
(AWG 25...AWG 14)
2 conductors 0.2 to 1.5 mm
2
(AWG 25...AWG 16)
Tightening torque =
0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm)
Also valid for spring cage connectors (ref 88 970 313 and 88 970 317 for the RBT range)
Earthing
Protection rating
Overvoltage category
Pollution
Max operating Altitude
Mechanical resistance
Resistance to electrostatic discharge
Resistance to HF interference
Conducted and radiated emissions
Operating temperature
Storage temperature
Relative humidity
Mounting
Screw terminals connection capacity
General characteristics
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
Welcome to Tucao——A collection of forum "editor" opinions and suggestions
[font=微软雅黑][size=3] Have you ever encountered some problems that made you feel unhappy or even crazy when posting or replying on the forum? [/size][/font][font=微软雅黑][size=3] For example: when editing ...
eric_wang Suggestions & Announcements
2003 Introduction to Darlington Transistor Arrays: Features and Applications
2003 Introduction to Darlington Transistor Arrays: Features and Applications Alternative models: ULN2003 UF2003 QL2003 VTSR2003 Overview The 2003 is a monolithic high voltage, high current Darlington ...
godot Power technology
35 51 MCU examples
Share "51 MCU Examples 35" for beginners, very detailed. I started with the MCU by watching it....
songbo 51mcu
Ask about the problem of high current monitoring!
I want to monitor the sudden current on the high-voltage tower. The current is estimated to be more than 2KA. Is there such a monitoring module?...
紫麓寒枭 Embedded System
MSP430 program library digital tube display
[i=s] This post was last edited by Baboerben on 2019-4-12 19:40 [/i] [size=4] Digital tubes are also one of the most commonly used output devices in single-chip microcomputer systems (along with liqui...
灞波儿奔 Microcontroller MCU
Wince EBOOT problem
I modified the EBOOT boot program of PXA270 a few days ago, and wanted to use SD card to update NK. In debugging EBOOT, because there was no perfect debugging tool, I debugged by printing information ...
icai Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1325  2276  850  1306  2750  27  46  18  56  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号