J2R0021-38-21
l
O D2210V
R
REED SWITCH
ORD2210V
Vacuum High Power
n
GENERAL DESCRIPTION
The ORD2210V is a small single-contact reed switch of a vacuum type designed for ultra high
breakdown voltages 1000 V DC between the reed contacts.
n
FEATURES
(1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive
any influence from the external atmospheric environment.
(2) Quick response
(3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed
switches are suited to applications in radio frequency operation.
(4) Reed switches are compact and light weight.
(5) Superior corrosion resistance and wear resistance of the contacts assures stable switching
operation and long life.
(6) With a permanent magnet installed, reed switches economically and easily become
proximity switches.
n
EXTERNAL DIMENSIONS (Unit: mm)
f0.6
MAX f2.75
MAX 21.0
55.4±0.3
n
APPLICATIONS
l
Automotive electronic devices
l
Control equipment
l
Communication equipment
l
Measurement equipment
l
Household appliances
111
l
ORD2210V
n
ELECTRICAL CHARACTERISTICS
Parameter
Pull-in Value (PI)
Drop-out Value (DO)
Contact resistance (CR)
Breakdown voltage
Insulation resistance
Electrostatic capacitance
Maximum switching voltage
Maximum switching current
Maximum carry current
Rated value
Unit
20∼60
7min
100
1000
10
10
min
0.5max
100
350DC
300AC
1.0
2.5
AT
AT
mW
VDC
W
pF
VA
V
V
A
A
(1) Drop-out Value vs. Pull-in Value
(2) Contact resistance
99.9
(Measurement length: 32mm)
Cumulative frequency percent (%)
AT
50
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
20
30
40
50
60
40
60
80
100
m
W
Drop-out Value
40
30
20
10
0
Pull-in Value
AT
Contact resistance
112
ORD2210V
l
(3) Breakdown voltage
(4) Insulation resistance
99.9
(DC
100V)
Cumulative frequency percent (%)
10
20
30
40
50
60
AT
5000
DC:V
4000
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
10
10
11
10
12
10
13
10
14
Breakdown voltage
3000
2000
1000
0
W
Pull-in Value
Insulation resistance
(5) Electrostatic capacitance
(1MHz)
pF
Electrostatic capacitance
0.4
0.3
0.2
0.1
0
10
20
30
Pull-in Value
40
50
60
AT
113
l
ORD2210V
n
OPERATING CHARACTERISTICS
Parameter
Operate time
Bounce time
Release time
Resonant frequency
Maximum operating frequency
Rated value
0.6max
0.5max
0.05max
2500±250
500
Unit
ms
ms
ms
Hz
Hz
(1) Operate time
(25Hz: 100AT energized)
(2) Bounce time
(25Hz: 100AT energized)
99.9
Cumulative frequency percent (%)
ms
0.5
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
0.4
Operate time
0.3
0.2
0.1
0
10
20
30
40
50
Pull-in Value
60
AT
0
0.1
0.2
0.3
0.4
ms
Bounce time
(3) Release time
(4) Resonant frequency
99.9
Cumulative frequency percent (%)
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
(25Hz: 100AT energized)
m
s
15
Release time
10
5
0
10
20
30
40
50
AT
2250
2500
2750
Hz
Drop-out Value
Resonant frequency
114
ORD2210V
l
n
MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(2.27kg-10sec)
AT
60
Cumulative frequency percent (%)
Pull-in Value • Drop-out Value
(2) Lead tensile strength
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
0
2
4
6
8
10kg
50
40
PI
30
20
DO
10
0
mW
80
Breaking load
Contact resistance
60
CR
40
Before test
After test
n
ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics
%
40
CR
30
Rate of change percent
20
DO
PI
0
10
−10
−20
−30
−40
−20
0
20
40
60
80
100
120
℃
Temperature
115