Product data sheet
Characteristics
SM956A810000
ultrasonic sensor cylindrical M30 - Sn8m -
0..10V - M12
Main
Range of product
Sensor type
Series name
Device short name
Sensor design
[Sn] nominal sensing
distance
Type of sensing win-
dow
Material
Enclosure material
Front material
Type of output signal
ISO thread
Wiring technique
[Us] rated supply volt-
age
Supply voltage limits
Analogue output range
Electrical connection
Product specific appli-
cation
Hyde Park
Ultrasonic sensor
Superprox 900
SM956
Cylindrical M30
8m
Adjustable
Plastic
ULTEM
Analog
M30 x 1.5
4-wire
15...24 V DC (overload and short-circuit protection)
13...28 V DC
0...10 V direct
1 male connector M12 4 pins
-
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Glass epoxy
Complementary
[Sd] sensing range
[Sa] assured operating distance
Maximum differential travel
Blind zone
Transmission frequency
Repeat accuracy
Beam angle
Minimum size of detected object
Current consumption
Maximum switching current
Resistance to electrostatic discharge
Height
Width
Depth
Length
Product weight
0.203...8 m
0.203...8 m with teach pushbutton
12.7 mm
0...203 mm
75 kHz
2.54 %
10 °
Cylinder diameter 50.8 mm - up to 4572 mm sensing distance
80 mA
60 mA (reverse polarity protection)
8 kV (level 4) conforming to IEC 61000-4-2
30 mm
43.18 mm
30 mm
117.3 mm
0.9 kg
Environment
Product certifications
Marking
NEMA degree of protection
IP degree of protection
Ambient air temperature for operation
Ambient air temperature for storage
Jul 20, 2017
UL
CE
NEMA 4X (indoor use only)
IP67
-20...60 °C
-20...80 °C
1
Relative humidity
Vibration resistance
Shock resistance
Resistance to electromagnetic fields
Resistance to fast transients
100 % without condensation
+/-1 mm conforming to IEC 60068-2-6 10...55 Hz
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
10 V/m (level 3) conforming to IEC 61000-4-3
1 kV (level 3) conforming to IEC 61000-4-4
2