16W Single Output LED Power Supply
■
Features :
PLD-16
series
115VAC or 230VAC models available
Built-in active PFC function
Constant current design
Protections: Short circuit / Over temperature
Cooling by free air convection
Fully isolated plastic case
Class 2 Power Unit
Class
Ⅱ
power unit, no FG
IP42 design
Suitable for indoor LED lighting applications
100% full load burn-in test
Low cost
High reliability
3 years warranty
F
110
( for B type only)
( for B type only)
( for 350mA)
(except for 350mA)
IP42
SELV
( for A type only) ( for B type only)
( for B type only)
PLD-16-350 A
A : With AC input 90~ 135VAC.
B : With AC input 180~ 295VAC.
SPECIFICATION
MODEL
RATED CURRENT
CURRENT ACCURACY
RATED POWER
PLD-16-350
350mA
±5.0%
16.8W
16.8W
2.7Vp-p
35V
16.8W
2.2Vp-p
25V
16.8W
2Vp-p
16V
OPERATING VOLTAGE RANGE
24 ~ 48V
OUTPUT
PLD-16-700
700mA
16 ~ 24V
PLD-16-1050
1050mA
12 ~ 16V
PLD-16-1400
1400mA
8 ~ 12V
RIPPLE & NOISE (max.)
Note.1
4.6Vp-p
NO LOAD OUTPUT VOLTAGE (max.)
60V
SETUP TIME
FREQUENCY RANGE
47 ~ 63Hz
500ms / 230VAC 2000ms / 115VAC at full load
INPUT
PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
POWER FACTOR (Typ.)
A series THD< 20% when output loading
≧
70% at 115VAC
TOTAL HARMONIC
DISTORTION
B series THD< 20% when output loading
≧
70% at 230VAC input and output loading
≧
80% at 277VAC input
84.5%
84%
82.5%
A series 84.5%
EFFICIENCY (Typ.)
86%
85%
83.5%
B series 85.5%
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
MAX. No. of PSUs
on 16A CIRCUIT
BREAKER
0.4A/115VAC 0.2A/230VAC
0.15A/277VAC
COLD START 20A(twidth=25
μ
s measured at 50% Ipeak) at 230VAC
A series 58 units (circuit breaker of type B) / 58 units (circuit breaker of type C) at 115VAC
B series 128 units (circuit breaker of type B) / 128 units (circuit breaker of type C) at 230VAC
<0.5mA / 240VAC
Hiccup mode, recovers automatically after fault condition is removed.
Shut down o/p voltage, re-power on to recover
-30 ~ +50
℃
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
℃
, 10 ~ 95% RH
±
0.03%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750,CSA C22.2 No.250.0-08(except for PLD-16-350);ENEC EN 613471-1,EN 61347-2-13 independent,
EN62384(for B type only), IP42 approved
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55015 (B type only), EN61000-3-2 Class C ; EN61000-3-3, FCC part 18 non-consumer equipment(A type only)
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level, criteria A
906.5Khrs min. MIL-HDBK-217F (25
℃
)
84*57*29.5mm (L*W*H)
0.19Kg; 72pcs/14.7Kg/0.92CUFT
LEAKAGE CURRENT
PROTECTION
SHORT CIRCUIT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
3. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
File Name:PLD-16-SPEC 2015-08-21