Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V
t
10%)
4.9 - 5.3
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
49
X
17
X
94mm (W
X
H
X
D) / 65g max
Convection
15
0.7
60max
120max
120max
160max
150max
180max
150max
60max
24
0.5
96max
150max
120max
160max
150max
180max
240max
96max
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
Works over 105% of rating and recovers automatically
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
50
X
17
X
115mm (W
X
H
X
D) / 80g max
Convection
INPUT
LCA
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24, 36, 48V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
34.5 - 37.5
46.0 - 50.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
50
X
25
X
132.5mm (W
X
H
X
D) / 150g max
Convection
INPUT
LCA
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
As the title says, I use a STC12C2052AD microcontroller AD acquisition port to measure the voltage of a lithium battery. I found that the battery voltage will have a certain impact on the voltage of o...
This seminar mainly introduces two new Hall position sensors MLX90421/2. They are a new generation of products based on the optimized design of Melexis second-generation position sensors, which fully ...
This year, the company changed its "supplier" for bottled water. After a while, I felt a little strange. I didn't hear my colleagues calling for water, but there were always one or two full buckets of...
Requirements: (1) The voltage amplitude of the amplifier input sinusoidal signal is 10mV, and the voltage gain is 40dB. e=12pt], the gain is 10dB[/size][/font][size=12pt] adjustable in steps, the pass...
If the ultimate form of a car is a silicon-based life form, then in
the field of
intelligent driving
, it has gradually taken on the appearance of a "veteran driver." In
the field of
the ...[Details]
As the number of cars increases, environmental pressures are also increasing. At this time, some people are saying that new energy vehicles are energy-efficient and environmentally friendly, and ar...[Details]
Multi-touch mobile phone
Multi-touch is a system that can respond to multiple touches on the screen at the same time. Multi-touch phones are divided into capacitive and resistive types. Capaci...[Details]
In mobile technology, sensors are the primary input for measured signals and form a component of a sensor system. They include sensitive and transducer elements connected to carriers and circuits. ...[Details]
Logic analyzers are widely used tools in digital design verification and debugging. They can verify the proper functioning of digital circuits and help users identify and troubleshoot faults. They ...[Details]
Robotics
has become
LiDAR
's "second growth curve."
While LiDAR was still battling with its "pure vision" rivals in the automotive field, another field ignited the demand f...[Details]
The all-new MG4 was recently officially announced on the Ministry of Industry and Information Technology's (MIIT) new vehicle announcement. The all-new MG4's semi-solid-state battery version addres...[Details]
Laird Thermal Systems has introduced the HiTemp ET series Peltier cooler modules, which can operate at high temperatures and provide on-site cooling for sensitive electronic devices.
Dig...[Details]
Linear motor modules have become the "sweet spot" in various fields due to their advantages such as long stroke, fast speed, high precision, smooth operation and long life. Different models of line...[Details]
On August 21st, BYD announced the launch of its next-generation "Little White Pile" product, the "Lingchong"
charging
pile
, which is now available for general sale. This charging pile feat...[Details]
The difference between a series inverter and a parallel inverter is that they use different oscillation circuits. A series inverter connects L, R, and C in series, while a parallel inverter connect...[Details]
Shenzhen Baowei Power Supply high frequency pure sine wave power, communication inverter power supply has two communication interfaces, RS232 and R485 interfaces, their functions and characteristic...[Details]
New version helps developers build secure and trustworthy embedded systems
Shanghai, China—August 21, 2025—
QNX, a division of BlackBerry Ltd., today announced the release of QNX...[Details]
The mobile computing market is rapidly evolving, and manufacturers are fiercely competing for market share. A key area of competition is battery life, which encompasses two key aspects: how long th...[Details]
introduction
With the development of the information superhighway and the internet, broadcast television has become increasingly widespread worldwide. Television information has emerged in var...[Details]