EEWORLDEEWORLDEEWORLD

Part Number

Search

LCA30SA-5-Y

Description
Switching Power Supplies AC/DC PS(Open frame)
Categorysemiconductor    Power management   
File Size854KB,15 Pages
ManufacturerCosel
Download Datasheet Parametric View All

LCA30SA-5-Y Online Shopping

Suppliers Part Number Price MOQ In stock  
LCA30SA-5-Y - - View Buy Now

LCA30SA-5-Y Overview

Switching Power Supplies AC/DC PS(Open frame)

LCA30SA-5-Y Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCosel
Product CategorySwitching Power Supplies
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 15 VDC
Number of Outputs1 Output
Output Power30 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 132 VAC/110 VAC to 170 VDC
Output Current-Channel 16 A
IndustryCommercial
Isolation Voltage2 kV
Mounting StyleChassis
Length132.5 mm
Width50 mm
Height23 mm
Input Frequency47 Hz to 440 Hz
Load RegulationRegulated
Power - Convection30 W
Factory Pack Quantity50
Unit Weight5.291094 oz
AC-DC Power Supplies Open Frame/Enclosed type
Ordering information
LCA10S
R
LC
1
2
A
3
10
4
S
5
-5
6
-O
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
1Series
name
2100/120V
input
3Output
wattage
4Single
output
5Output
voltage
6Optional
*3
C :with Coating
G :Low leakage current
Y :with Potentiometer
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LCA10S-5
10
5V 2A
LCA10S-5-H
10
5V 2A
LCA10S-12
10.8
12V 0.9A
LCA10S-15
10.5
15V 0.7A
LCA10S-24
12
24V 0.5A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A] ACIN 100V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
TEMPERATURE REGULATION[mV]
*
2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
LCA10S-5
LCA10S-5-H
AC85 - 132 1
f
or DC110 - 170
0.3typ (Io=100%)
47 - 440 or DC
71typ
71typ
25typ (Io=100%)
0.5max (60Hz, According to UL, CSA and
5
5
2
2 (Peak 3)
LCA10S-12
LCA10S-15
LCA10S-24
INPUT
75typ
DEN-AN)
12
0.9
48max
100max
120max
160max
150max
180max
120max
48max
75typ
78typ
LCA
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
20max
20max
40max
40max
80max
80max
140max
140max
120max
120max
160max
160max
50max
50max
20max
20max
100max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%)
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V
t
10%)
4.9 - 5.3
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
49
X
17
X
94mm (W
X
H
X
D) / 65g max
Convection
15
0.7
60max
120max
120max
160max
150max
180max
150max
60max
24
0.5
96max
150max
120max
160max
150max
180max
240max
96max
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
LCA-2
【TI recommended course】#LED function introduction and LED driver design considerations#
//training.eeworld.com.cn/TI/show/course/5688...
tvb2058 TI Technology Forum
How to solve the problem that the IO port voltage is affected when the microcontroller measures the battery voltage
As the title says, I use a STC12C2052AD microcontroller AD acquisition port to measure the voltage of a lithium battery. I found that the battery voltage will have a certain impact on the voltage of o...
gxp790953623 MCU
Live broadcast at 10 am today [A new generation of products based on the optimized design of Melexis second-generation position sensors]
This seminar mainly introduces two new Hall position sensors MLX90421/2. They are a new generation of products based on the optimized design of Melexis second-generation position sensors, which fully ...
EEWORLD社区 Sensor
Ten major misunderstandings in PCB design - the endless equal length (Part 2)
[size=4]Author: Wu Jun[/size] [size=4] [/size] [align=center][size=4][color=#0000ff]Part 1[/color][/size][/align] [align=center][b][size=4]About Equal Length and Equal Timing[/size][/b][/align] [size=...
ohahaha PCB Design
Admiration for a water carrier
This year, the company changed its "supplier" for bottled water. After a while, I felt a little strange. I didn't hear my colleagues calling for water, but there were always one or two full buckets of...
向农 Talking about work
MAX264 programmable filter design (amplifier requires AD817)
Requirements: (1) The voltage amplitude of the amplifier input sinusoidal signal is 10mV, and the voltage gain is 40dB. e=12pt], the gain is 10dB[/size][/font][size=12pt] adjustable in steps, the pass...
cliu_seven MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 600  636  1150  2448  2920  13  24  50  59  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号