EEWORLDEEWORLDEEWORLD

Part Number

Search

LER00950PAYVKEAF15

Description
Industrial Pressure Sensors Transportation Pressure Switches
CategoryThe sensor   
File Size2MB,13 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

LER00950PAYVKEAF15 Online Shopping

Suppliers Part Number Price MOQ In stock  
LER00950PAYVKEAF15 - - View Buy Now

LER00950PAYVKEAF15 Overview

Industrial Pressure Sensors Transportation Pressure Switches

LER00950PAYVKEAF15 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerHoneywell
Product CategoryIndustrial Pressure Sensors
NumOfPackaging1
CE
IEC/EN-60947-5-1
Installation Instructions for the
Honeywell Pressure Switches
High Pressure: HP Series, HE Series
Medium Pressure: MH Series, ME Series
Low Pressure: LP Series, LE Series
(3.5 psi to 4500 psi [0,24 bar to 310,26 bar])
MECHANICAL REQUIREMENTS
Installation Requirement
The Honeywell Pressure Switches, High Pressure, Medium
Pressure, and Low Pressure, are capable of being mounted in
any orientation via a threaded port. A 27 mm hexagonal wrench
should be used to install the pressure switch. Installation torque
should be based on the information in Table 1. Installation of
the pressure switch shall permit usage of maximum 27 mm hex
box spanner, modified socket wrench, and open-ended wrench.
Rev. D
50038194
Table 1. Installation Torque
Thread
M10 × 1.0
M12 × 1.5
M14 × 1.5
M18 × 1.5
1/2-20 UNF
9/16-18 UNF
7/16-20 UNF
3/4-16 UNF
7/8-14 UNF
G1/8 BSPP
G1/4 BSPP
1/4-18 NPT
1/8-27 NPT
1/8-27 PTF
R1/8 BSPT
R1/2 - 14 BSPT
R1/2 BSPT
R1/4 BSPT
Torque (Nm)
15
25
35
45
25
30
18
50
60
25
50
1-Screw in until
handtight
2-Then tighten the ASME B 1.20.1
product by two to
three threads using
wrench
Standard
ISO 6149-3
ISO 6149-3
ISO 6149-3
ISO 6149-3
SAE J1926-3
SAE J1926-3
SAE J1926-3
SAE J1926-3
SAE J1926-3
ISO 1179-3
ISO 1179-3
INSTALLATION
,
CAUTION
PRODUCT DAMAGE
Use a hex wrench for installation. DO NOT exceed a
torque level based on the information in Table 1. Never
apply torque to the connector housing or the body of the
pressure switch.
Do not subject the pressure switch to high tempera-
tures from soldering, brazing, or welding of the system
plumbing or operating environments above the specified
maximum temperature.
Failure to comply with these instructions could result in
death or serious injury.
Ensure the power supply is off while wiring.
The pressure switch can withstand a side load (acting
perpendicular to the mounted axis) of 100 Newton at the
end of the integral connector in its mounted orientation. This
load requirement is for any incidental physical abuse during
installation or intended use.
Safety and Productivity Solutions
The necessity of a software platform
At present, with the rapid growth of MCU, most small and medium-sized companies are forced to abandon the 8-bit CPU platform and turn to 32-bit MCU. Many people often calculate the cost of the chip, b...
jorya_txj Embedded System
The text read out using CEDIT can be displayed, but when dragging the scroll bar, the text overlaps. When these words are selected and refreshed, the overlap disappears. How can I solve this problem?
The text read out using CEDIT can be displayed, but when dragging the scroll bar, the text overlaps. When these words are selected and refreshed, the overlap disappears. How can I solve this problem?...
miaoer Embedded System
TMS320F28335ADC Detailed Explanation
The TMS320F28335 contains a 12-bit AD converter with the following features: 12-bit ADC core with built-in (sample and hold) S/H Analog input: 0.0V to 3.0V (voltages above 3.0V produce full-scale conv...
灞波儿奔 Microcontroller MCU
How to analyze whether flash data transmission is normal
Hello everyone, there is a batch product error. After replacing the new batch of flash, the function is normal. How can I determine that the flash has failed and is abnormal in hardware? How can I vie...
youn@g Analog electronics
Phase-Shifted Zero-Voltage Soft-Switching Converter and Application of UC3875
Abstract: This paper introduces the development process and main development direction of switching power supplies, focusing on the working principle and process of phase-shifted soft-switching conver...
zbz0529 Energy Infrastructure?
Design rules for four-layer PCB
In the design of PCB multi-layer boards, four-layer boards are generally used more. So, do you know what are the design rules of PCB four-layer boards?1. Design of four-layer board:(1) Uniform spacing...
就某个水呀 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1272  1977  981  1517  385  26  40  20  31  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号