EEWORLDEEWORLDEEWORLD

Part Number

Search

TB200-02QC4

Description
Barrier Terminal Blocks BARRIER BLOCK
CategoryThe connector    terminals   
File Size62KB,1 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

TB200-02QC4 Online Shopping

Suppliers Part Number Price MOQ In stock  
TB200-02QC4 - - View Buy Now

TB200-02QC4 Overview

Barrier Terminal Blocks BARRIER BLOCK

TB200-02QC4 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Base Number Matches1
MAGNUM
®
Top & Bottom Marking Strips
Double Row Terminal Blocks (TB100, TB200, TB300, TB345 SERIES)
Single & Double Row
Filtered Connectors
TOP MARKER STRIPS
Top mounting marker strips are available in white (opaque)
plastic. Two cover clips are supplied with each marker
strip.
All top marker strips must be ordered separately. Consult
factory for special legends.
Example: 12 position cover, TB200, .032” x .312”, with no
legends . . . Part No. is X20312.
Example: 12 position cover, TB200HB, .060” x .500”, with
no legends . . . Part No. is X23312HB.
Euro-MAG Series
PCB – Spring Clamp
Part Numbering System
Series
Top Marker Strip
Poles
X
133
- TB100 (.060 thk x .500w)
103
- TB100 (.032 thk x .312w)
233
- TB200 (.060 thk x .500w)
233TB
- TB200HB (.060 thk x .500w)
203
- TB200 (.032 thk x .312w)
203HB
- TB200HB (.032 thk x .312w)
333
- TB300 & TB345 (.060 thk x .500w)
303
- TB300 & TB345 (.032 thk x .380w)
02
to
36
(TB100)
02
to
30
(TB200/TB200HB)
02
to
24
(TB300/TB345)
Note: Marking Strips are not available on
TB400 Series.
Base & Rail Mount
Connectors
BOTTOM MARKER STRIPS;
Bottom mounting marker strips are made of black PVC,
.030” thick. Space is available to handle most marking sit-
uations. All marker strips must be ordered separately.
To order, specify part number, required legends and (BF)
bottom forward, (BR) bottom reverse, (TF) top forward, or
(TR) top reverse. Consult factory for specials.
Space for marking
one side
Space for marking
two sides
Power Distribution Blocks
Example: 13 position strip, TB100 with no legends, space
for marking one side . . . Part No. is X10513.
Position for legends (one side, two sides) can be specified
standard. Standard legend height is .125”. Standard leg-
ends are 0-99 and A-Z. Special legends are available on
special order. Drawing(s) must be submitted to ensure
accuracy of part required.
TB100
Dim. A
Dim. B
1.13”
1.38”
TB200
1.37”
1.62”
TB200HB
1.62”
1.81”
TB300
1.58”
1.81”
TB345
1.58”
1.81”
TB400
N/A
N/A
Part Numbering System
Series
Bottom Marker Strip
Poles
Orientation
WIRE MANAGEMENT PRODUCTS
X
105
101
205
201
295
291
305
301
-
-
-
-
-
-
-
-
TB100 – marking one side
TB100 – marking both sides
TB200 – marking one side
TB200 – marking both sides
TB200HB – marking one side
TB200HB – marking both sides
TB300 & TB345 – marking one side
TB300 & TB345 – marking both sides
02
to
36
(TB100)
02
to
30
(TB200/TB200HB)
02
to
24
(TB300/TB345)
BF
– bottom forward
BR
– bottom reverse
TF
– top forward
TR
– top reverse
Note: Marking Strips are not available on TB400 Series.
36
Some basic concepts in PCB design
1. The concept of "layer" is similar to the concept of "layer" introduced in word processing or many other software to achieve the nesting and synthesis of pictures, texts, colors, etc. The "layer" of...
Jacktang PCB Design
Under what circumstances will the output end of the A/D sampling and conditioning circuit become suspended?
I'm new to this and need some advice. I've seen that many sampling circuits have a pull-up resistor added before they are connected to the IO port. However, when there is no input to many op amps, the...
电源小白鼠 Analog electronics
ADUCM350: 16-BIT ADC for M3 Core
ADuCM350 is a button cell powered, on-chip metering chip for pocket devices, healthcare diagnostics, life information collection for wearable products, etc. ADuCM350 can be used for high-precision pot...
dontium ADI Reference Circuit
What is the relationship between the hive registry and the kernel?
Can the nk registry not be cleared after re-flashing (i.e. not restored to the value in platform.reg)? Isn't the registry in the kernel? Where is the registry cleared when re-flashing the kernel?...
illino Embedded System
How to deal with the 2440 external interrupt pin when it is not in use?
I brought out the interrupt pin on the board but I don't need it now. I want to fix it. From: EEWORLD cooperation group 63762526, group owner: wangkj...
WLJP PCB Design
keil for arm, the value saved in the address is correct, but the monitored variable value is incorrect?
I'm asking about stm32 programming. When calculating and assigning values to the local variable u32 in a function, the result in the register is correct in the assembly, and the value assigned to the ...
lzfmars stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 354  889  2525  2015  216  8  18  51  41  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号