P3/9
ECN3067
4.Electrical Characteristics
Unless otherwise specified, Vcc=15V,VS=325V
Suffix T: Top arm
Ta = 25°C
No.
Items
1 Standby Current
2
3
4
5
6
7
8
Turn On Delay
Time
Turn Off Delay
Time
B: Bottom Arm
Symbols Terminal
IS
VS1,VS2
ISB
BU-MU,BV-
MV,BW-MW
MIN.
-
-
-
-
-
-
-
-
-
-
-
3.5
-
-100
-30
TYP.
-
15
10
2.5
2.5
1.0
1.0
1.0
1.0
2.5
2.5
-
-
-
-
7.5
-
0.5
300
11.4
0.4
11.4
0.4
10
2.0
MAX.
0.25
30
20
3.5
3.5
2.0
2.0
2.0
2.0
3.5
3.5
-
1.5
-
-
8.2
-
0.55
400
13.0
0.9
13.0
0.9
20
3.0
Unit
mA
mA
mA
V
V
ms
ms
ms
ms
V
V
V
V
mA
mA
V
mA
V
W
V
V
V
V
ms
ms
Condition
Input=“H”
BU-MU,BV-MV,
BW-MW=15V
Output device FVD
ICC
VFT
VFB
TdONT
VCC
MU,MV,MW
MU,MV,MW
MU,MV,MW
I=1.5A
PW<5ms
I=1.5A
PW<5ms
TdONB
MU,MV,MW
TdOFFT
MU,MV,MW
TdOFFB
VFDT
VFDB
VIH
VIL
IIL
IIH
VB
IB
Vref
Ronf
Vuvb
Vrhb
Vuvt
Vrht
tflrs
toc
CB
CB
RS
F
VCC
VCC
BU-MU,BV-
MV,BW-MW
F
RS
MU,MV,MW
MU,MV,MW
MU,MV,MW
UT,VT,WT,
UB,VB,WB
UT,VT,WT,
UB,VB,WB
I=1.5A
Resistive
Load
I=1.5A
PW<5ms
9
10 Diode FVD
11
12 Input Voltage
13
14 Input Current
15
16 VB Output Voltage
17 VB Output Current
18 Over Current
reference Voltage
19 Fault output on
resistance
20
Vcc Under Voltage Negative Going
21
Reset Hysterisis
22
V
BU,BV,BW
Under
Negative Going
23
Voltage
Reset Hysterisis
24 Fault reset delay time
25 OC shutdown delay
Input=0V
Note 1
Input=5V
Note 1
dVLOAD=
0.2V
6.8
50
0.45
-
9.8
0.1
9.8
0.1
6.5
-
Note 2
Note 3
Note 4
Note 1. Pull Up Resistance are typically 200kW
Note 2. The equivalent circuit around F terminal is shown
below.
Note 3. Please see item 5.4.
Note 4. Please see item 5.4.
CB
F
PDE-3067-1
P4/9
ECN3067
5. Function
5.1. Truth Table
Terminal
UT,VT,WT,
UB,VB,WB
UT,UB
VT,VB
WT,WB
Input
L
H
UT&UB=L
VT&VB=L
WT&WB=L
Output
ON
OFF
OFF
OFF
OFF
5.2 Timing Chart(Example of Brushless Motor drive)
UT
Top Arm
VT
W T
UB
Bottom Arm
VB
W B
M U
M V
OUTPUT
OUTPUT
M W OUTPUT
5.3 Over Current Operation
This IC detects over current by checking the
Voltage drop at the external resistance RS. When
typ 200kW
VB
typ 220kW
typ
5pF
Vref
S
Latch
R
the input voltage at RS terminal exceeds the
internal reference voltage (Vref), this IC turns off
the output of all arms circuit and F terminal output
becomes “L”. After over current detection, reset is
done when all six inputs are referenced to high level.
In case of not using this function, please connect
this terminal to GL terminal (within 100
W).
RS
typ 300W
Reset signal
RS terminal inner equivalent circuit
PDE-3067-1
P5/9
ECN3067
5.4 Undervoltege Detection
1) When Vcc supply voltage becomes below Vuvb(11.4V typ.), all of the IGBTs shut off and F
terminal output becomes “L”.
2) When between BU-MU, BV-MV or BW-MW voltage become below Vuvt(11.4V typ.), top arm
IGBT of under voltage detected phase shuts off. In this time, F terminal output doesn’t change.
Note 1. When VCC supply voltage becomes lower, driving capability of IGBT also becomes lower.
Accordingly, power dissipation becomes higher and this causes temperature raise of IC.
In case of junction temperature exceeds 135°C, IC may deteriorate or breakdown.
5.5 Definition of switching delay
50%
50%
Input
(UT,UB VT,VB WT,WB)
80%
Output Current
(MU,MV,MW)
20%
Tdon
Tdoff
Input
(UT,UB VT,VB WT,WB)
RS
F
50%
50%
50%
50%
50%
Output
(MU,MV,MW)
tflt
toc
tflrs
PDE-3067-1