EEWORLDEEWORLDEEWORLD

Part Number

Search

F601AH333K630L

Description
Film Capacitors
CategoryPassive components   
File Size355KB,13 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

F601AH333K630L Online Shopping

Suppliers Part Number Price MOQ In stock  
F601AH333K630L - - View Buy Now

F601AH333K630L Overview

Film Capacitors

F601AH333K630L Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerKEMET
Product CategoryFilm Capacitors
MMK
• Metallized polyester
• According to CECC 30401-042, IEC 60384-2, DIN 44122
L
RoHS
Compliant
B
typical applications
Bypassing, signal coupling. General
purpose for highest reliability.
construction
Metallized polyester film capacitor. Radial
leads of tinned wire are electrically welded
to the contact metal layer on the ends of
the capacitor winding. Encapsulation in
self-extinguishing material meeting the
requirements of UL 94V-0.
H
0.5
p
d
b
l
technical data
Rated voltage U
R
, VDC
Rated voltage U
R
, VAC
Capacitance, µF
Capacitance tolerance
Category temperature range
Voltage derating
Rated temperature
Climatic category
Test voltage
50
30
63
40
100
63
250
160
400
200
630
220
1000
250
p
p
7.5 ± 0.4
5.0 ± 0.4
10.0 ± 0.4
7.5 ± 0.4
15.0 ± 0.4
10.0 ± 0.4
15.0 ± 0.4
22.5 ± 0.4
22.5 ± 0.4
27.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
37.5 ± 0.5
d
d
std l max l
std I max I
4
+1
+1
4
6
-1
+1
4
6
-1
+1
4
4
6
-1
+1
4
+1
6
-1
4
+1
6
-1
+1
4
b
b
0.001 0.001 0.001 0.001 0.001 0.001 0.001
–10.0 –82
–82
–39
–18
–6.8 –4.7
±20%, ±10% standard, ±5%.
–55 ... +100°C
Above +85°C DC and AC voltage derating is 1.25%/°C.
+85°C
IEC 60068-1, 55/100/56
DIN 40040, FME
–55 ... +100°C (+125°C)
Average relative humidity ≤ 75 %
RH = 95% for 30 days per year.
RH = 85% for further days limited by average value per
year, occasional slight condensation permitted.
1.6 x U
R
VDC for 2s
Max. 2% after a 2 year storage period at a temperature
of +10 ... +40°C and a relative humidity of 40...60%.
Operational life > 200 000 h.
Failure rate < 3 FIT, T = +40°C, U = 0.5 x U
R
.
Failure criteria according to DIN 44122.
0.6
0.5
0.6
0.6
0.8
0.6
0.8
0.8
0.8
0.8
0.8
1.0
1.0
20
20
± 0.4
± 0.4
30
20
± 0.4
± 0.4
30
± 0.4
30 ± 0.4
30
± 0.4
± 0.4
30
30
± 0.4
± 0.4
30
30 ± 0.4
30
± 0.7
30 ± 0.7
Z (Ω)
10
1.0
0.0
0.1
01
0.0
1
0.1
0.01
1
0.1
1.0
10
100 MHz
Capacitance drift
Reliability
Resonance frequencies
MMK 5
Z (Ω)
10
1.0
Maximum pulse
steepness:
Temperature coefficient
Self inductance
dU/dt according to article table. For peak to peak
voltages lower than rated voltage (U
pp
< U
R
), the
specified dU/dt can be multiplied by the factor U
R
/U
pp
.
+400 (±200) ppm/°C at 1 kHz
Approximately 6 nH/cm for the total length of capacitor
winding and the leads.
0.0
0.1
1
0.0
01
0.1
1.0
0.01
10
22
0.1
1.0
10
100 MHz
environMental test data
Damp heat test
Endurance test
Test conditions:
Test criteria:
Test conditions:
Test criteria:
T = +40°C, RH = 93%, t = 56 days.
∆ C/C ≤ ±5%,
∆ tanδ ≤ 0.005 (1kHz),
IR after test 0.5 x IR min.
T = +100°C, U = 1.25 x (0.8 x U
R
),
t = 2000 h.
∆ C/C ≤ ±5%,
∆ tanδ ≤ 0.005 (1kHz)
∆ tanδ ≤ 0.010 (100kHz)
IR after test 0.5 x IR min.
Resonance frequencies
MMK7.5 ... 37.5
TSP distributed control increases test speed and reduces test costs
TSP technology enhances instrument control by allowing users to use standard PC control or create embedded test scripts that execute on the microprocessor within the instrument. By using TSP test scri...
Jack_ma Test/Measurement
Please help look at this program!
#include#pragma vector = PORT1_VECTOR __interrupt void Port_1(void) { volatile unsigned int i; // volatileWhen programming the source code, do not use optimization for this variablefor (i = 0; i30000;...
Hsiang Microcontroller MCU
Orcad Capture CIS automatically numbers after deleting a component, and DRC appears when importing the netlist into Allegro
For example, I drew 10 resistors, numbered R1~R10, and the connections were already drawn in Allegro. Then I deleted R5 in the schematic, renumbered it automatically, and then imported it into the net...
ayu_ag PCB Design
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. Then the heart rate...
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. So how is heart rate detection achieved? What a...
QWE4562009 Discrete Device
ActiveSync installation error
I encountered an error when installing ActiveSync. The error message was "Error writing to file: C:\Program Files\Microsoft ActiveSync\wcesmgr.exe, please verify that you have access to the directory....
han0602 Embedded System
The 2450 board runs fine at 400M, but crashes when playing CMMB TV at 533M???
Dear hardware and software experts, this problem has puzzled me for a long time. Could you please analyze the reason? Can Shuiyan also help analyze it? The problem is this: We use Samsung's S3C2450 pl...
qiaoli Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2213  2354  2743  2446  1115  45  48  56  50  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号