88826103

Description
Timers MUR3 TIMER FUNC U 12-240V DIN RL17.5MM
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size227KB,5 Pages
ManufacturerCrouzet
Download Datasheet Parametric View All

88826103 Online Shopping

Suppliers Part Number Price MOQ In stock  
88826103 - - View Buy Now

88826103 Overview

Timers MUR3 TIMER FUNC U 12-240V DIN RL17.5MM

88826103 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCrouzet
Product CategoryTimers
RoHSN
TypeSolid State Timer
Timing Range0.1 s to 100 h
Display TypeLED Indicator
Accuracy+/- 0.5 %
Current Rating8 A
Operating Temperature Range- 20 C to + 60 C
Termination StyleScrew
Mounting StyleDIN Rail
Operating Supply Voltage12 V to 240 V
Factory Pack Quantity1
Unit Weight2.821917 oz
11/03/2013
www.crouzet.com
17.5 mm DIN rail mounting MUR3 Part number 88826103
TO BE SOON REPLACED BY THE NEW CHRONOS 2 RANGE (ref. 88827...)
Relay or solid state output
Multi-function or mono-function
Multi-range
Multi-voltage
Screw or spring terminals
LED status indicator (relay version)
Option of connecting an external power supply to the control input
3-wire sensor control option
Part numbers
Type
88 826 103
MUR3
Functions
A - At - B - C - H - Ht-Di - D - Ac - Bw
Timing
0,1s→100h
Output
1 changeover relay
Nominal rating
8A
Connections
Screw terminals
Supply voltage
12→240 V AC/DC
Specifications
Timing
Timing ranges (7 ranges)
Repetition accuracy with constant parameters
Drift Temperature
Drift Voltage
Display accuracy according to IEC/EN 61812-1
Minimum pulse duration typically (relay version)
Minimum pulse duration typically (solid state version)
Minimum pulse duration typically (relay version under
load)
Maximum reset time by de-energisation typically (relay
version)
Maximum reset time by de-energisation typically (solid
state version)
Immunity from micro power cuts : typical
Supply
Multi-voltage power supply
Frequency (Hz)
Operating range
Operator factor
Max. absorbed power
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
TK2R1 : 0.6s - 2.5s - 20s - 160 s
± 0.5 % (IEC/EN 1812-1)
± 0,05 % / °C
± 0.2 % / V
± 10 % / 25 °C
30 ms
50 ms
100 ms
100 ms
350 ms
> 10 ms
*** TRADUCTION MANQUANTE ***
Depending on version
50 / 60
85 to 110 % Un
(85 to 120 % Un for 12V AC/DC)
100 %
0,6 W 24 V AC/DC
1,5 W 230 V AC
32 VA 230 V AC
Output specification
1 or 2 changeover relays, AgNi (cadmium-free)
Rated power
Maximum breaking current
Minimum breaking current
Voltage breaking capacity
Electrical life (operations)
Mechanical life (operations)
Breakdown voltage acc. to IEC/EN 61812-1
Impulse voltage acc. to IEC/EN 60664-1, IEC/EN 61812-1
2000 VA/80 W
2000 VA/80 W
8 A AC 8A DC
10 mA / 5 V DC
250 V AC/ DC
10
5
operations 8 A 250 V resistive
5x10
6
2.5 kV /1 min / 1 mA / 50 Hz
5 kV, wave 1.2 / 50
μs
Solid state output
Rated power
Derating
Maximum admissible current
Minimum breaking current
Leakage current
Voltage breaking capacity
Maximum voltage drop at terminals
Electrical life (operations)
Mechanical life (operations)
Breakdown voltage acc. to IEC/EN 60664-1, IEC/EN
60255-5
0,7 A AC/DC
20 °C (0,5 A UL)
5 mA / °C
20 A ≤ 10 ms
10 mA
< 5 mA
250 V AC/ DC
3 wire 4V - 2 wire 8V
10
8
10
8
2.5 kV to 1 mA / 1 min
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
I would like to ask you, how much is the cheapest 2.8 inch 320X240 TFT?
I would like to ask you, what is the cheapest price of a 2.8-inch 320X240 TFT? Thank you!...
zhou.63624 stm32/stm8
Application of observer-based method in three-phase inverter fault diagnosis
In recent years, with the continuous improvement of control theory, research on fault diagnosis of control systems has attracted more and more attention [1][2], and many research results have been ach...
zbz0529 Test/Measurement
What is the difference between multiplicative DA and ordinary DA?
I hope you can explain the difference between multiplication type DA and ordinary DA....
wstt TI Technology Forum
Keil5 software simulation problem
When keil5 software is simulating, I set a breakpoint in the main function, and then click run to try to jump to the breakpoint, but the following situation occursSet the breakpoint at the LED0=1 stat...
反倒是fdsf stm32/stm8
Multi-core DSP Applications in the SoC Era
[i=s]This post was last edited by fish001 on 2018-6-21 21:40[/i] [size=5] One of the most important application areas of multi-core DSP is 3G digital mobile communication. This includes applications i...
fish001 DSP and ARM Processors
Let's talk about the main parameters of MOS
1. Turn on voltage VT  Turn-on voltage (also known as threshold voltage): the gate voltage required to start forming a conductive channel between the source S and the drain D;  Standard N-channel MOS ...
qwqwqw2088 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1946  2568  1697  2106  976  40  52  35  43  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号