Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
•
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
•
Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
•
Terminals face the front when the cover is removed for
easy connection.
•
Switches with ground terminals have CE marking.
•
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Be sure to read
Safety Precautions
on page 8 to 9 and
Safety Precautions for All Limit Switches.
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_4_1
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3)
(4)
(3) Actuator
Q
Q22
Q21
QA2
QA277
N
N22
N21
NA2
NA277
: Plunger
: Roller plunger
: Crossroller plunger
: Roller arm lever
: One-way action roller arm lever
: Sealed plunger
: Sealed roller plunger (ZE, ZV, ZV2 only)
: Sealed crossroller plunger (ZE, ZV, ZV2 only)
: Sealed roller arm lever
: Sealed one-way action roller arm lever
(1) Built-in Switch
Z
X
: SPDT (AC)
: SPDT (DC)
(4) Conduit/Ground Terminal
*
None
G1
G
SG1
YG1
S
Y
: G 1/2/without ground terminal
: G 1/2/with ground terminal
: Pg13.5/with ground terminal
: 1/2-14NPSM/with ground terminal
: M20/with ground terminal
: 1/2-14NPSM/without ground terminal
: M20/without ground terminal
(2) Mounting Direction
E : Side mounting
V : Base mounting
V2 : Diagonal side mounting
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
1
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Side mounting
Base mounting
Diagonal side mounting
Mounting
Actuator
AC
Plunger
DC
AC
Roller plunger
DC
General
purpose
AC
Crossroller plunger
DC
AC
Roller arm lever
DC
One-way action roller
arm lever
AC
DC
AC
Sealed plunger
DC
Sealed roller plunger
Sealed
(Booted)
Sealed crossroller
plunger
Sealed roller arm lever
DC
One-way action
sealed roller arm lever
AC
DC
AC
AC
AC
Model
ZE-Q-2
XE-Q-2
ZE-Q22-2
XE-Q22-2
ZE-Q21-2
XE-Q21-2
ZE-QA2-2
XE-QA2-2
ZE-QA277-2
XE-QA277-2
ZE-N-2
XE-N-2
ZE-N22-2
ZE-N21-2
ZE-NA2-2
XE-NA2-2
ZE-NA277-2
XE-NA277-2
Approved
standards
UL
●
CSA
●
Model
ZV-Q-2
XV-Q-2
Approved
standards
UL
●
CSA
●
Model
ZV2-Q-2
XV2-Q-2
Approved
standards
UL
●
CSA
●
●
●
ZV-Q22-2
XV-Q22-2
●
●
ZV2-Q22-2
XV2-Q22-2
●
●
●
●
ZV-Q21-2
XV-Q21-2
●
●
ZV2-Q21-2
---
●
●
●
●
ZV-QA2-2
XV-QA2-2
●
●
ZV2-QA2-2
XV2-QA2-2
ZV2-QA277-2
---
●
●
●
●
---
---
●
●
●
●
ZV-N-2
XV-N-2
●
●
ZV2-N-2
XV2-N-2
●
●
●
●
●
●
●
●
ZV-N22-2
ZV-N21-2
ZV-NA2-2
XV-NA2-2
●
●
●
●
●
●
ZV2-N22-2
ZV2-N21-2
ZV2-NA2-2
XV2-NA2-2
●
●
●
●
●
●
●
●
ZV-NA277-2
---
●
●
ZV2-NA277-2
XV2-NA277-2
●
●
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Agency
UL
CSA
CCC (CQC)
Standard
UL508
CSA C22.2 No.14
GB14048.5
File No.
E76675
LR45746
2003010303077623
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Non-inductive load (A)
Model
Rated
voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Resistive load
NC
ZE-@
ZV-@
ZV2-@
15
15
10
0.5
0.25
10
10
10
10
3
3
3
3
3
1.5
NO
Lamp load
NC
3
2.5
1.5
0.5
0.25
1.5
1.5
1.5
1.5
0.75
NO
1.5
1.25
0.75
NC
15
15
6
0.05
0.03
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
Inductive load (A)
Inductive load
NO
Motor load
NC
5
3
1.5
0.05
0.03
2.5
2.5
2.5
2.5
1.5
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.
NO
2.5
1.5
0.75
Inrush
current
NC
NO
30 A max.
15 A max.
XE-@
XV-@
XV2-@
2
ZE/ZV/ZV2/XE/XV/XV2
Approved Standard Ratings
UL/CSA
Model
Rated voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
Current
15 A
15 A
15 A
0.5 A
0.25 A
Horsepower
1/8HP
1/4HP
---
Operating speed
Durability
*2
Characteristics
Degree of protection
Mechanical
IP65*1
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Z@: 500,000 operations min., for 15 A,
250 VAC resistive load
X@: 100,000 operations min., for 10 A,
125 VDC resistive load
Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
120 operations/min
20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
50°C max.
1,000 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude*3
1,000m/s
2
max.
100 m/s
2
max.*4
50 m/s
2
max.*5
−10°C
to +80°C (with no icing)
General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Approx. 260 to 280 g
ZE
Electrical
CCC (GB14048.5)
Applicable category and ratings
AC-12 10 A/250 VAC
Mechanical
Electrical
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Between terminals
of the same polarity
Between current-
carrying metal
Dielectric
part and ground
strength
Between each
terminal and
non-current-car-
rying metal part
Vibration
Malfunction
resistance
Destruction
Shock
resistance
Malfunction
*3
Operating
frequency
Ambient operating temperature
Ambient operating humidity
Weight
Note: The above figures are initial values.
*1. IP65 for
@-N
models and IP60 for
@-Q
models.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm
lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.
Engineering Data
Electrical Durability
ZE (cosφ = 1)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
125 VAC
500
250 VAC
100
480 VAC
50
0
2
4
6
8
10
12
14 16
Switching current (A)
ZE (cosφ = 0.4)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
500
250 VAC
480 VAC
100
50
0
2
4
6
8
10
12
14
16
125 VAC
Switching current (A)
3
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure
ZE-NA2-2
COM
NC
NO
Contact Form
Pin plunger
Tightening band
Case
Rubber cap (CR)
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
+ terminal.
Separator
Built-in switch
Terminal
Conduit
opening
Cover
Seal rubber (NBR)
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.
Dimensions and Operating Characteristics
Side Mounting Models
Plunger
ZE-Q-2
XE-Q-2
Two, M4
(length: 45)
(Unit: mm)
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Plunger
ZE-Q22-2
XE-Q22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
PT
OP
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
25.4
±
0.12
24
OP
23
23
25.4
±
0.3
25.4
±
0.3
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
Two, M4
(length: 45)
19.1 dia.
×
7.9 *1
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
17
39.7
*2
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
23
25.4
±
0.3
* Stainless steel roller
25.4
±
0.3
86
25.4
±
0.12
24
*1. Stainless sintered roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Operating
characteristics
Operating force
Release force
Pretravel
Over Travel
Movement Differential
Operating Position
Model
OF
RF min.
PT max.
OT min.
MD max.
OP
ZE-Q-2
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
XE-Q-2
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
ZE-Q22-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q22-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-Q21-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q21-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-QA2-2
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
---
XE-QA2-2
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
38.2±0.8 mm
49.7±1 mm
49.7±1 mm
4
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZE-QA277-2
18.7 dia.
×
9 *1
XE-QA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Operate in this
direction only
Sealed Plunger
ZE-N-2
XE-N-2
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
39.7
*2
PT
PT
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
Two, M4
(length: 45)
Two, M4
(length: 45)
17
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
OP
23
25.4
±
0.3
25.4
±
0.12
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
24
25.4
±
0.3
25.4
±
0.12
24
Sealed Roller Plunger
ZE-N22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
Sealed Crossroller Plunger
ZE-N21-2
PT
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
OP
Two, M4
(length: 45)
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
23
23
25.4
±
0.3
25.4
±
0.3
* Stainless steel roller
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
19.1 dia.
×
7.9 *1
39.7
(23.1)
*2
One-way Action Sealed Roller Arm Lever
18.7 dia.
×
9 *1
ZE-NA277-2
XE-NA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
Operate in this
direction only
39.7
*2
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
Two, M4
(length: 45)
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
17
23
23
25.4
±
0.3
25.4
±
0.3
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
*1. Stainless steel roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
The company has a project in June that may require writing a host computer, and it needs to be written in C#. I have no foundation in this area, so I hope someone who is good at C# can recommend an en...
About mobile GPS map navigation. Has anyone done mobile GPS map navigation? What kinds of maps are available? Do you have to pay to buy maps? What interfaces do maps provide? How do you connect maps t...
I have never been exposed to embedded systems before. Now I am just starting to learn. I have read several books but I still don't understand them. What book should I read? Or can I download a tutoria...
[font=宋体][size=9pt]Whether you are a radio enthusiast or a maintenance technician, can you tell what the small components on the circuit board are called and what their functions are? If you want to b...
At present, mobile phone and router manufacturers often use concepts such as "dual-band" in their promotions. When we connect to WiFi networks, we often see the words 2.4G and 5G. At the same time, wh...
Reflow soldering is a critical process in electronics assembly production, and the cleanliness of the reflow oven has a direct impact on product quality. Dust and residue accumulation within the ov...[Details]
Flip-chip and ball grid array (BGA) are two widely used packaging technologies in the electronics industry. Each has its own advantages and limitations, and in some cases, they can complement each ...[Details]
"Have you set your calendar reminder?"
On August 24, Nvidia Robotics' official account posted a photo of a black gift box on a social media platform, with an attached greeting card sig...[Details]
With the rapid development of technology, automotive intelligence is increasing at an unprecedented rate. This not only enhances vehicle functionality and comfort, but also places higher deman...[Details]
In recent years, with the application of the IEC61850 standard and the development and deployment of optoelectronic transformers, the concept of digital substations has been put into practical use ...[Details]
On August 25th, SK Hynix announced that it has completed development and entered mass production of its 321-layer, 2Tb QLC NAND flash memory product. This achievement marks the world's first applic...[Details]
According to foreign media reports, BMW has just been granted a patent for a screen that could cover the entire roof. BMW hopes to transform at least a portion of the vehicle's headliner into a dis...[Details]
On August 21st, Zhiyuan Robotics revealed at its first partner conference that it expects shipments to reach thousands of units this year and tens of thousands next year. The company hopes to reach...[Details]
There are basically three causes of spontaneous combustion of electric vehicles: The first is that the battery components are punctured or suffer fatal damage due to a collision accident, and part ...[Details]
Industrial computers with GPUs leverage powerful parallel processing to build deep learning models to analyze and respond to optical inputs. The systems develop an understanding of visual data to i...[Details]
Through AI connection technology supported by Qualcomm X85 5G modem and RF and Qualcomm FastConnect 7900 mobile connection system, seamless switching can be achieved between cellular net...[Details]
A multilevel inverter converts a DC signal into a multilevel staircase waveform. Instead of a straight positive-negative output waveform, the output waveform of a multilevel inverter alternates in ...[Details]
According to Nikkei, a survey found that global electric vehicle battery supply is expected to reach more than three times the required quantity due to
cooling
demand for electric vehicles,...[Details]
The MCX E series is the most reliability- and safety-focused series in NXP's extensive MCX product portfolio.
With the launch of this series, NXP has further enriched its 5V-compatible MCU pr...[Details]
Tiantai Robot's official Weibo account announced on the evening of August 20 that Tiantai Robot Co., Ltd., together with strategic partners including Shandong Future Robot Technology Co., Ltd., Sha...[Details]