Safety Relay
OA 5622 / OA 5622S
Features
n
n
n
n
n
n
n
n
n
n
n
6 output contacts
International approvals:
TÜV, UL, cUL
Quality control check for each safety relay
Forced-guided contacts, all gold flash plated
Contact Gap > 0.5 mm throughout life of relay
Various contact materials,
mixed contact material optional
High coil voltage range
High breakdown voltage: contact/coil
≥
4 KV
contact/contact
≥
4KV
High creeping distance: contact/coil
≥
5.5 mm
contact/contact
≥
5.5 mm
Protection Rating IP 67, washable
Custom design available,
- coil voltage
- coil resistance,
- contact pressure
- operate/release time
- gold plated double contacts
S-Type
higher external clearance and creeping distance:
contact/contact
≥
7.5 mm
C
GERMANY
US
n
USA/CANADA
E146415
Technical Data
n
n
n
n
n
n
n
n
n
n
n
Nominal Coil Voltage
.......................................................
...............................................6, 12, 24, 48, 60, 110, DC
Coil Power Dissipation
..........................................0.8 W
Max. Switching Voltage
....................250V DC, 400V AC
Max. Switching Current
.........8 A (5 x 8A simultaneous)
Max. Switching Power — DC.................................200W
Max. Switching Power — AC..............................2000VA
Contact Switching Rate
.........10 operations per second
Relay Operate Time
...............................................12 ms
Relay Release Time
.................................................8 ms
Operation Vibration
.........................0.35 mm Ampl. max
......................................................@ 10...200Hz, 5g max
Contact Arrangements....................................................
......................2NO/4NC, 3NO/3NC, 4NO/2NC, 5NO/1NC
Contact Material...................AgNi10+0.2µmAu
Standard
...................AgSnO
2
+0.2µmAu, AgNi10+5µmAu Optional
Mechanical Life
.......................>20x10
6
operation cycles
Electrical Life
..............AgSnO
2
>10
5
, AgNi10 >0.75x10
5
......................operation cycles @ 230V AC, 8A, cos
ϕ=1
Ambient Temperature....................................-40...+80°C
Cover Material
..............................................Polyamide 6
Weight........................................................................38
g
More detailed data upon request
n
n
n
n
n
n
n
Diagrams
Relay operation voltage vs. ambient
temperature
Limitation factor for inductive loads
Maximum switching power curve
Mechanical life
12
Altech Corp.
®
• 35 Royal Road • Flemington NJ 08822-6000 • Phone (908) 806-9400 • FAX (908) 806-9490 • www.altechcorp.com