Part Number

Search

280-CR10-120-RC

Description
Wirewound Resistors - Through Hole 120ohms 5% Tol
CategoryPassive components   
File Size217KB,2 Pages
ManufacturerXicon Passive Components
Websitehttp://www.xicor.com
Download Datasheet Parametric View All

280-CR10-120-RC Online Shopping

Suppliers Part Number Price MOQ In stock  
280-CR10-120-RC - - View Buy Now

280-CR10-120-RC Overview

Wirewound Resistors - Through Hole 120ohms 5% Tol

280-CR10-120-RC Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerXicon Passive Components
Product CategoryWirewound Resistors - Through Hole
RoHSDetails
Resistance120 Ohms
Power Rating10 W
Tolerance5 %
Temperature Coefficient350 PPM / C
Operating Temperature Range- 55 C to + 155 C
Length49 mm
Width10 mm
Height9 mm
Termination StyleAxial
PackagingBulk
ProductPower Resistors Wirewound Cement Filled Ceramic
TypeCement Power Resistor
Lead Diameter0.75 mm
Maximum Operating Temperature+ 155 C
Minimum Operating Temperature- 55 C
Factory Pack Quantity10
Cement Power Resistors
(RoHS Compliant)
FEATURES
• Temperature Range: -55°C ~ +155°C
• 5% tolerance
• Exceptionally small, sturdy, and reliable
• Sealed with a special cement
• Excellent moisture resistance
• High temperature stability
• Ceramic flame retardant package
• Recommended wash method is alcohol
HEAT RISE CHART
250
Heat Rise (ϒ
C)
200
150
100
Percent Rated Load (%)
25W
10W
15-
If you need to reduce this logo,
only do so on the page you are
adding it to. This is the original
and must not change.
CR-RC Series
DERATING CURVE
100
80
60
40
20
0
-50
0 50 100 150 200 250 300
Ambient Temperature (ϒ
C)
70ϒ
155
275
5W
0
20 40 60 80 100
Rated Load (%)
PART NUMBERING SYSTEM
2
8
Prefix
0
C
R
5
Watts
-
1
0
Value
K
-
R
C
Series
Suffix (RoHS Compliant)
SERIES, WATTAGE, VALUE-RANGE, AND DIMENSIONS
d
H
I
Watts
(W)
5
10
15
25
L
I
W
Dimensions (mm)
H ±1
9
9
11.5
13.5
Series
CR
CR
CR
CR
Value Ranges (Ω)
Wire Wound
Metal Oxide
0.1 ~ 47
48 ~ 25K
0.1 ~ 910
911 ~ 25K
1 ~ 1K
- - N/A - -
2 ~ 1.0K
- - N/A - -
L ±1
22
49
49
64
W ±1
10
10
12.5
14.5
I ±5
35
35
35
35
d ±0.05
0.75
0.75
0.75
0.75
STANDARD STOCKED VALUES (Ω)
0.15
0.2
0.22
0.27
0.3
0.1
0.33
0.39
0.43
0.47
0.5
0.51
0.56
0.62
0.68
0.75
0.82
0.91
1.0
1.1
1.2
1.3
1.5
1.6
1.8
2.0
2.2
2.4
2.7
3.0
3.3
3.6
3.9
4.0
4.3
4.7
5.0
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
16
18
20
22
24
25
27
30
33
36
39
43
47
50
51
56
62
68
75
82
91
100
110
120
130
150
160
180
200
220
240
250
270
300
330
360
390
430
470
500
510
560
620
680
750
820
1.0K
1.1K
1.2K
1.3K
910
1.5K
1.6K
1.8K
2.0K
2.2K
2.4K
2.7K
3.0K
3.3K
3.9K
4.7K
5.0K
10K
20K
25K
*Other values available by special request
XICON PASSIVE COMPONENTS • (800) 628-0544
XC-600041
Specifications are subject to change without notice. No liability or warranty implied by this information. Environmental compliance based on producer documentation.
Date Revised: 05/15/17
8-bit simple CPU
Is there anyone in the forum who has made a simple 8-bit CPU using Verilog? Please give me some advice. The simulation was done using modesim. I tried Xia Yuwen's design, but the simulation was unsucc...
鑫海宝贝 FPGA/CPLD
Help installing cadence (IC5.0) on a virtual machine
Can I install LINUX on a virtual machine and then install IC5.0? If so, what are the specific steps? Thank you...
high2162 FPGA/CPLD
The list of top 100 credits has been announced! The campaign to get on the list has entered the final stage! Hurry up!
[font=微软雅黑][size=3]The first round of the ranking activity is already halfway through, let's take a look at how everyone's performance is! The list of the top 100 credits has been announced, come and ...
linjiang TI Technology Forum
The 430 key can only use interrupt codes?
I wrote a button P1DIR&=~BIT0; IF(P1IN&BIT0!=BIT0)〔 delay(); IF(P1IN&BIT0!=BIT0)〕but it doesn't work. I found that P1IN seems to be changing all the time. Can any kind-hearted person help explain it? ...
数码小叶 Microcontroller MCU
Recommended: Share a super anti-interference, waterproof, cost-effective touch IC
A 1-16 channel capacitive touch sensing chip with super anti-interference and waterproof capabilities. It can work in switching power supply systems with different frequencies and non-isolated RC step...
renbubin1979 MCU
This is my first time drawing, I hope you can see if there are any flaws
I have never drawn before, but I finally finished it today. I know asking this question may bother the seniors, but I only know that the lines should be crossed vertically, and the rest are randomly p...
zxpla PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1007  571  1610  8  1878  21  12  33  1  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号