EEWORLDEEWORLDEEWORLD

Part Number

Search

2026-23-C4LF

Description
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 230VOLT
CategoryWireless rf/communication    Telecom circuit   
File Size327KB,5 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2026-23-C4LF Online Shopping

Suppliers Part Number Price MOQ In stock  
2026-23-C4LF - - View Buy Now

2026-23-C4LF Overview

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 230VOLT

2026-23-C4LF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instruction,
Reach Compliance Codecompliant
Factory Lead Time5 weeks
JESD-30 codeO-XXSS-P3
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Number of terminals3
Maximum operating temperature90 °C
Minimum operating temperature-40 °C
Package body materialUNSPECIFIED
Package shapeROUND
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelINDUSTRIAL
Terminal surfaceTin (Sn)
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced TRIGARD
®
Approximately 8 mm diameter, 11 mm long
UL Recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Aircraft and military electronics
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
(1)
Model No.
2026-07
75 V
275 V
700 V
2026-09
90 V
275 V
600 V
2026-15
150 V
350 V
575 V
2026-20
200 V
425 V
625 V
2026-23
230 V
450 V
650 V
2026-25
250 V
475 V
700 V
2026-26
260 V
475 V
700 V
Model No.
2026-30
300 V
550 V
775 V
ribution.
2026-35
350 V
625 V
875 V
2026-40
400 V
675 V
925 V
2026-42
420 V
725 V
1000 V
2026-47
470 V
800 V
1100 V
2026-60
600 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/μs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
(2)
...............................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20
μs
(3)
.................................................. 1 operation minimum
20000 A, 8/20
μs
...................................................... > 10 operations
5000 A, 10/350
μs
................................................... 1 operation
1000 A, 10/1000
μs
................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
(3)
............................................. 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Moisture Sensitivity Level ............................................................................................................................... 1
............................................................................................................................... 6
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering
process that does not exceed 210 °C.
Notes:
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108
Ω
(-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
(2)
(3)
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
WARNING Cancer and Reproductive Harm
www.P65Warnings.ca.gov
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice. Users should verify actual device performance in their specific
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the
last page of this document, and at
www.bourns.com/docs/legal/disclaimer.pdf.
How to learn FAT file system
by xwj Actually, FAT is very easy to understand. 1. You first find the partition table from the MBR (master boot sector). (This is easy to find and is in the first sector of any hard disk.) 2. Then yo...
clark Microchip MCU
Car emergency brake flash device
[i=s] This post was last edited by sf116 on 2018-9-30 21:11 [/i] 1. Introduction In traffic accidents, rear-end collisions caused by the front car's sudden braking often occur. Rear-end collisions are...
sf116 GD32 MCU
I want to use this method to change the PWM output. Has anyone used it before?
Time-Base Period Shadow Mode:The TBPRD shadow register is enabled when TBCTL[PRDLD] = 0. Reads from and writes to theTBPRD memory address go to the shadow register. The shadow register contents are tr...
安_然 Microcontroller MCU
WINCE power management and battery drive issues?
I wrote a battery driver myself. Can I read the battery status and voltage normally (through the I2C interface)? The driver returns the corresponding parameter structure in BatteryPDDGetStatus. BOOL W...
xiaolu192 Embedded System
Detailed explanation of semiconductor thermal resistance problem
This article is a reorganization of my previous article "On Thermal Resistance Issues" and explains it according to more rigorous logic.The relationship between the thermal resistance of a transistor ...
Fireflye Integrated technical exchanges
Servo System Summary
1. Background knowledge The full digital servo system generally adopts a three-loop structure of position control, speed control and torque control. The system hardware is roughly composed of the foll...
tianshi227 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1078  2024  505  2249  24  22  41  11  46  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号