THROUGH BEAM SENSOR
DL40 • DLM50 • DLV60
MINI THROUGH BEAM SENSOR
with separate amplifier
·
·
·
·
·
long range
high excess gain
different ways of installation
highly flexible connecting cable
robust design
•
Ø 4 mm x 11 mm
•
Stainless steel
•
f. gluing a. clamping fixture
•
M5 x 0,5 mm x 11 mm
•
Nickel-plated brass
•
f. screw-in fixture
•
6 mm x 6 mm x 12 mm
•
Nickel-plated brass
•
f. screw-in fixture
GENERAL TECHNICAL DATA
light type
connection type
temperature range
Red 660nm or Infrared 880nm
PUR-cable with connector
-10°C to +55°C
DL40
Actual size
DLM50
Actual size
DLV60
Actual size
protection class
IP 65
SMALLEST OBJECT and SENSING DISTANCE
sensing distance
smallest object
(Ø copper wire)*
*copper wire of infinite length
1000 mm
0,3 mm
03/02
DL40 • DLM50 • DLV60
Measurements in mm. Subject to technical change.
DIMENSIONS
ø4.0
10.0
5.0
12.0
M2
1.5
8.0
03/02
DL40
SW 8
6.0
DLM50
DLV60
PART DESIGNATION
DL40
light type
R:
Red light
(blank):
Infrared light
_
_
:
cable length
(specifications in [m] )
standard length 1m
special cable length
jacket material
connector
0:
M8 - connector 3 pin, female
P:
PUR-cable black
Ø1,8mm
1:
719 - Binder connector
(see page
Options and Accessories)
F:
highly flexible PUR-cable red Ø1,1mm
ORDER EXAMPLE:
DL40R-P-0:1m
= DL40 Red light
-
PUR-cable black
-
M8, 3 pin female: (cable length1m x 2)
Please remember, for correct operation, a separate amplifier is required.
6.0
M5x0.5
10.0
2.0